Osvaldo Zmener
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Osvaldo Zmener has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Gladys Banegas
Department of Adult Dental Care, Faculty of Odontology, University of Buenos Aires, Argentina
3 shared publicationsCornelis H. Pameijer
University of Connecticut School of Dentistry, Farmington, CT, USA
2 shared publicationsG. Banegas
Department of Adult Dental Care, Faculty of Odontology, University of Buenos Aires, Buenos Aires, Argentina
2 shared publicationsC. H. Pameijer
University of Connecticut School of Dental Medicine, Farmington, CT, USA
1 shared publication- Cornelis H. Pameijerb
Department of Reconstructive Sciences, School of Dental Medicine, University of Connecticut, Farmington, CT 06030, USA
1 shared publication F. Grimberg
Department of Adult Dental Care, Faculty of Odontology, University of Buenos Aires, Argentina
1 shared publication
Latest Publications
- 6 October 2006
- Published by Wiley in Dental Traumatology
- Vol. 23 (1) , 21-25
An in vitro study of the pH of three calcium hydroxide dressing materials
Abstract – Calcium hydroxide is widely used as a root canal dressing material because of its favorable alkalinizing effect. It has been suggested that the action comes from diffusion of hydroxyl ions through the apical foramen. The purpose of this in vitro study was to test the pH changes that occurred over a period of 30 days using a mixture of calcium hydroxide and distilled water and two commercial calcium hydroxide products in a simulated periapical environment. The materials were inserted in glass tubes closed at one end, which were placed in individual vials containing distilled water at a pH 7.4. Unfilled glass tubes were used as controls. Alkalinity changes of the medium were measured at 1 and 24 h and 15 and 30 days. The alkalinizing properties of all materials showed a rapid increase at 1 and 24 h followed by a continuous but more gradual increase from 15 to 30 days. The control tubes did not cause a change in pH of the medium, which remained at pH 7.4. At the end of the observation period, the alkalinizing properties of Calasept and Ultracal XS were significantly higher (P < 0.05) than the calcium hydroxide/distilled water paste.
- 6 October 2006
- Published by Wiley in Dental Traumatology
- Vol. 23 (1) , 21-25
An in vitro study of the pH of three calcium hydroxide dressing materials
Abstract – Calcium hydroxide is widely used as a root canal dressing material because of its favorable alkalinizing effect. It has been suggested that the action comes from diffusion of hydroxyl ions through the apical foramen. The purpose of this in vitro study was to test the pH changes that occurred over a period of 30 days using a mixture of calcium hydroxide and distilled water and two commercial calcium hydroxide products in a simulated periapical environment. The materials were inserted in glass tubes closed at one end, which were placed in individual vials containing distilled water at a pH 7.4. Unfilled glass tubes were used as controls. Alkalinity changes of the medium were measured at 1 and 24 h and 15 and 30 days. The alkalinizing properties of all materials showed a rapid increase at 1 and 24 h followed by a continuous but more gradual increase from 15 to 30 days. The control tubes did not cause a change in pH of the medium, which remained at pH 7.4. At the end of the observation period, the alkalinizing properties of Calasept and Ultracal XS were significantly higher (P < 0.05) than the calcium hydroxide/distilled water paste.
- 22 May 2006
- Published by Wiley in International Endodontic Journal
- Vol. 39 (7) , 521-526
Retreatment efficacy of hand versus automated instrumentation in oval‐shaped root canals: an ex vivo study
Aim To compare the efficacy of hand versus automated instrumentation when retreating oval‐shaped root canals.Methodology Sixty human premolars with single oval canals were instrumented and filled with gutta‐percha and sealer and divided into three groups (n = 20) – group 1: ProFile .04 taper rotary instruments; group 2: Anatomic Endodontic Technology (AET), and group 3: manual instrumentation with Hedström files. The teeth were split longitudinally and gutta‐percha/sealer remnants in the coronal, middle and apical thirds were assessed with light microscopy. The mean percentage of gutta‐percha/sealer remnants for each group was calculated and statistically analysed for significance using an anova repeated measures (P < 0.001) and Tukey's multiple comparison test. The time required for retreatment was analysed using a one‐way anova and Tukey's test (P < 0.001).Results Overall, 10–18% of the canal walls were covered with gutta‐percha/sealer remnants after preparation using any technique. Statistical analysis demonstrated that the mean values for remnants of filling material in the ProFile group were significantly higher than for the other groups (P < 0.001), except in the apical third where no significant difference occurred. In all groups, the mean values in the middle third were higher than the coronal and apical thirds. The retreatment time for ProFile and AET was significantly shorter compared to manual instrumentation with Hedström files (P < 0.001).Conclusions Under the experimental conditions, AET instruments and manual instrumentation with Hedström files resulted in cleaner canals. However, completely clean root canal walls were not produced with any of the techniques investigated.
- 22 May 2006
- Published by Wiley in International Endodontic Journal
- Vol. 39 (7) , 521-526
Retreatment efficacy of hand versus automated instrumentation in oval‐shaped root canals: an ex vivo study
Aim To compare the efficacy of hand versus automated instrumentation when retreating oval‐shaped root canals.Methodology Sixty human premolars with single oval canals were instrumented and filled with gutta‐percha and sealer and divided into three groups (n = 20) – group 1: ProFile .04 taper rotary instruments; group 2: Anatomic Endodontic Technology (AET), and group 3: manual instrumentation with Hedström files. The teeth were split longitudinally and gutta‐percha/sealer remnants in the coronal, middle and apical thirds were assessed with light microscopy. The mean percentage of gutta‐percha/sealer remnants for each group was calculated and statistically analysed for significance using an anova repeated measures (P < 0.001) and Tukey's multiple comparison test. The time required for retreatment was analysed using a one‐way anova and Tukey's test (P < 0.001).Results Overall, 10–18% of the canal walls were covered with gutta‐percha/sealer remnants after preparation using any technique. Statistical analysis demonstrated that the mean values for remnants of filling material in the ProFile group were significantly higher than for the other groups (P < 0.001), except in the apical third where no significant difference occurred. In all groups, the mean values in the middle third were higher than the coronal and apical thirds. The retreatment time for ProFile and AET was significantly shorter compared to manual instrumentation with Hedström files (P < 0.001).Conclusions Under the experimental conditions, AET instruments and manual instrumentation with Hedström files resulted in cleaner canals. However, completely clean root canal walls were not produced with any of the techniques investigated.
- 1 June 2005
- Published by Wolters Kluwer Health in Journal of Endodontics
- Vol. 31 (6) , 457-459
Bone Tissue Response to a Methacrylate-Based Endodontic Sealer: A Histological and Histometric Study
Successful endodontic treatment depends on thorough debridement of the root canal(s) and total obturation of the root canal space with an inert filling material. The use of gutta-percha in conjunction with a sealer is one of the most reliable methods for root canal obturation (1 ). Of a variety of sealers that have been developed to accomplish this, methacrylate resin-based sealers have shown promising results (2, 3, 4). They exhibit excellent adhesion to root canal walls (2 ) and good sealing properties (3, 4). Recently, a new methacrylate-based endodontic sealer, EndoRez (ER) (Ultradent Products, Inc., South Jordan, UT) has been introduced for filling root canals. ER is an hydrophilic, two-component, chemical-set material containing zinc oxide, barium sulfate, resins, and pigments in a matrix of urethane dimethacrylate resin. Preliminary observations (5, 6, 7) revealed that ER exhibited excellent adaptation to root canal walls (5 ), that is well tolerated by subcutaneous connective tissues in rats (6 ) and periapical tissues in subhuman primates (7 ). To date no studies have been conducted to analyze histologically the effect of ER implantation in bone. Therefore, the purpose of this study was to evaluate histologically and histometrically the effect of ER implantation in the tibias of rats.
- 1 June 2005
- Published by Wolters Kluwer Health in Journal of Endodontics
- Vol. 31 (6) , 457-459
Bone Tissue Response to a Methacrylate-Based Endodontic Sealer: A Histological and Histometric Study
Successful endodontic treatment depends on thorough debridement of the root canal(s) and total obturation of the root canal space with an inert filling material. The use of gutta-percha in conjunction with a sealer is one of the most reliable methods for root canal obturation (1 ). Of a variety of sealers that have been developed to accomplish this, methacrylate resin-based sealers have shown promising results (2, 3, 4). They exhibit excellent adhesion to root canal walls (2 ) and good sealing properties (3, 4). Recently, a new methacrylate-based endodontic sealer, EndoRez (ER) (Ultradent Products, Inc., South Jordan, UT) has been introduced for filling root canals. ER is an hydrophilic, two-component, chemical-set material containing zinc oxide, barium sulfate, resins, and pigments in a matrix of urethane dimethacrylate resin. Preliminary observations (5, 6, 7) revealed that ER exhibited excellent adaptation to root canal walls (5 ), that is well tolerated by subcutaneous connective tissues in rats (6 ) and periapical tissues in subhuman primates (7 ). To date no studies have been conducted to analyze histologically the effect of ER implantation in bone. Therefore, the purpose of this study was to evaluate histologically and histometrically the effect of ER implantation in the tibias of rats.
- 1 August 2004
- Published by Wolters Kluwer Health in Journal of Endodontics
- Vol. 30 (8) , 582-584
Coronal Microleakage of Three Temporary Restorative Materials: An In Vitro Study
The sealing properties of three temporary restorative materials, Cavit, IRM, and a polycarboxylate-based cement, Ultratemp Firm, were investigated in vitro. Standardized access cavities were prepared in 45, intact, extracted, human molars. The teeth were randomly assigned to three groups and the access openings filled with one of three temporary filling materials. In five teeth (negative control), no restorative material was placed but the preparations were coated entirely with sticky wax. The five teeth of the positive control group had no restorative material and no sticky wax applied. After thermocycling for 500 cycles (5–55°C), the experimental teeth were dipped in molten sticky wax to the CEJ. The coronal enamel was subsequently coated with two layers of nail varnish, leaving an area of 1 mm around the filling material uncovered. The samples were then immersed in 2% methylene blue dye solution for leakage assessment. The teeth were sectioned and the greatest depth of dye penetration was recorded. Positive control sections exhibited complete dye penetration, whereas negative controls had none. There was no statistically significant difference in marginal leakage between Cavit, IRM, and Ultratemp Firm (p > 0.05). All materials leaked at the interface material-dentin, whereas some IRM specimens absorbed the dye into the bulk of the material.
- 1 August 2004
- Published by Wolters Kluwer Health in Journal of Endodontics
- Vol. 30 (8) , 582-584
Coronal Microleakage of Three Temporary Restorative Materials: An In Vitro Study
The sealing properties of three temporary restorative materials, Cavit, IRM, and a polycarboxylate-based cement, Ultratemp Firm, were investigated in vitro. Standardized access cavities were prepared in 45, intact, extracted, human molars. The teeth were randomly assigned to three groups and the access openings filled with one of three temporary filling materials. In five teeth (negative control), no restorative material was placed but the preparations were coated entirely with sticky wax. The five teeth of the positive control group had no restorative material and no sticky wax applied. After thermocycling for 500 cycles (5–55°C), the experimental teeth were dipped in molten sticky wax to the CEJ. The coronal enamel was subsequently coated with two layers of nail varnish, leaving an area of 1 mm around the filling material uncovered. The samples were then immersed in 2% methylene blue dye solution for leakage assessment. The teeth were sectioned and the greatest depth of dye penetration was recorded. Positive control sections exhibited complete dye penetration, whereas negative controls had none. There was no statistically significant difference in marginal leakage between Cavit, IRM, and Ultratemp Firm (p > 0.05). All materials leaked at the interface material-dentin, whereas some IRM specimens absorbed the dye into the bulk of the material.
- 1 May 2004
- Published by Wolters Kluwer Health in Journal of Endodontics
- Vol. 30 (5) , 348-351
Tissue Response to a New Methacrylate-Based Root Canal Sealer: Preliminary Observations in the Subcutaneous Connective Tissue of Rats
Silicone tubes filled with EndoRez, a methacrylate-based root canal sealer, were implanted in the subcutaneous connective tissue of the rat. Solid, silicone rods of the same size as the tubes also were implanted and used as negative controls. The tissue reaction to test and control materials was histologically studied and analyzed by elemental electron-microprobe analysis. After 10, 30, 90, and 120 days of implantation, different grades of tissue reaction to the tested materials were recorded. A granulomatous tissue containing numerous polymorphonuclear leukocytes, lymphocytes, and plasmocytes, as well as macrophages and foreign-body giant cells with engulfed material in their cytoplasm, was initially observed in contact with EndoRez. Fibroblasts and newly formed vessels also were observed. This cellular profile persisted after 30 days. The severity of the reaction decreased with time, and connective tissue healing was observed at the 120-day observation period, even though some specimens exhibited a slight, persistent, inflammatory cell infiltration. The electron-microprobe analysis of the tissues revealed the presence of heavy components of EndoRez in all observation periods. In contact with the controls, there was an initially slight concentration of inflammatory cells. This reaction rapidly subsided after 30 days, and a fibrous connective tissue encapsulation, free of inflammatory cells, could be observed at the 90- and 120-day observation periods.
- 1 May 2004
- Published by Wolters Kluwer Health in Journal of Endodontics
- Vol. 30 (5) , 348-351
Tissue Response to a New Methacrylate-Based Root Canal Sealer: Preliminary Observations in the Subcutaneous Connective Tissue of Rats
Silicone tubes filled with EndoRez, a methacrylate-based root canal sealer, were implanted in the subcutaneous connective tissue of the rat. Solid, silicone rods of the same size as the tubes also were implanted and used as negative controls. The tissue reaction to test and control materials was histologically studied and analyzed by elemental electron-microprobe analysis. After 10, 30, 90, and 120 days of implantation, different grades of tissue reaction to the tested materials were recorded. A granulomatous tissue containing numerous polymorphonuclear leukocytes, lymphocytes, and plasmocytes, as well as macrophages and foreign-body giant cells with engulfed material in their cytoplasm, was initially observed in contact with EndoRez. Fibroblasts and newly formed vessels also were observed. This cellular profile persisted after 30 days. The severity of the reaction decreased with time, and connective tissue healing was observed at the 120-day observation period, even though some specimens exhibited a slight, persistent, inflammatory cell infiltration. The electron-microprobe analysis of the tissues revealed the presence of heavy components of EndoRez in all observation periods. In contact with the controls, there was an initially slight concentration of inflammatory cells. This reaction rapidly subsided after 30 days, and a fibrous connective tissue encapsulation, free of inflammatory cells, could be observed at the 90- and 120-day observation periods.
- 1 July 2002
- Published by Wiley in International Endodontic Journal
- Vol. 35 (7) , 590-593
In vivo determination of root canal length: a preliminary report using the Tri Auto ZX apex‐locating handpiece
Aim The aim of this study was to assess the clinical perfomance of a cordless handpiece with a built‐in apex locator – the Tri Auto ZX – designed for root canal preparation with nickel‐titanium rotary files. Methodology Twenty‐five human maxillary incisor and canine teeth scheduled for extraction with mature apices were selected for the study. Informed written consent was obtained from each patient before treatment. After administration of local anaesthesia, the teeth were isolated and the pulp cavities accessed. The Tri Auto ZX along with a size 15 K‐file was used in its electronic apex locating function based on the manufacturer's recommendations. A periapical radiograph with the file at the electronically determined constriction was taken, the file removed and the measurement registered as the electronic length (EL). To test the auto reverse function, a size 20 ProFile .04 taper NiTi rotary instrument was mounted in the handpiece. The point for the auto apical reverse function was preset on the panel at the 0.5 mm level. After the file was introduced into the canal and reached the predetermined level, the file automatically stopped and rotated in the opposite direction. A reference point was marked and this measurement was registered as the auto reverse length (ARL). All measurements were made twice by two different investigators. Teeth were then extracted and immersed in a 20% formalin solution for 48 h. After fixation, a size 15 file was inserted into the canal to measure the actual root canal length from the same reference point obtained with the Tri Auto ZX to the apical foramen, as seen in the stereo microscope. When the file tip was visible at the anatomical end of the canal it was withdrawn 0.5 mm and this measurement was registered as the actual length (AL). All measurements were expressed in mm and the measuring accuracy was set to 0.5 mm. The significance of the mean differences between EL and ARL and between EL and AL measurements at the 5% confidence level was evaluated. Results EL measurements were coincident to ARL in all instances. EL and ARL were coincident to AL in 10 (40%) canals, in the remaining 15 canals (60%) the AL measurements were longer than EL and ARL (+0.5 mm) in 14 instances and shorter (–0.5 mm) in one case. Overall, the AL was longer than the EL or ARL, the mean difference being –0.23 mm ± 0.32 (P < 0.05). Conclusions It was concluded that the Tri Auto ZX was useful and reliable. The Tri Auto ZX measurements protected against overpreparation.
- 1 July 2002
- Published by Wiley in International Endodontic Journal
- Vol. 35 (7) , 590-593
In vivo determination of root canal length: a preliminary report using the Tri Auto ZX apex‐locating handpiece
Aim The aim of this study was to assess the clinical perfomance of a cordless handpiece with a built‐in apex locator – the Tri Auto ZX – designed for root canal preparation with nickel‐titanium rotary files. Methodology Twenty‐five human maxillary incisor and canine teeth scheduled for extraction with mature apices were selected for the study. Informed written consent was obtained from each patient before treatment. After administration of local anaesthesia, the teeth were isolated and the pulp cavities accessed. The Tri Auto ZX along with a size 15 K‐file was used in its electronic apex locating function based on the manufacturer's recommendations. A periapical radiograph with the file at the electronically determined constriction was taken, the file removed and the measurement registered as the electronic length (EL). To test the auto reverse function, a size 20 ProFile .04 taper NiTi rotary instrument was mounted in the handpiece. The point for the auto apical reverse function was preset on the panel at the 0.5 mm level. After the file was introduced into the canal and reached the predetermined level, the file automatically stopped and rotated in the opposite direction. A reference point was marked and this measurement was registered as the auto reverse length (ARL). All measurements were made twice by two different investigators. Teeth were then extracted and immersed in a 20% formalin solution for 48 h. After fixation, a size 15 file was inserted into the canal to measure the actual root canal length from the same reference point obtained with the Tri Auto ZX to the apical foramen, as seen in the stereo microscope. When the file tip was visible at the anatomical end of the canal it was withdrawn 0.5 mm and this measurement was registered as the actual length (AL). All measurements were expressed in mm and the measuring accuracy was set to 0.5 mm. The significance of the mean differences between EL and ARL and between EL and AL measurements at the 5% confidence level was evaluated. Results EL measurements were coincident to ARL in all instances. EL and ARL were coincident to AL in 10 (40%) canals, in the remaining 15 canals (60%) the AL measurements were longer than EL and ARL (+0.5 mm) in 14 instances and shorter (–0.5 mm) in one case. Overall, the AL was longer than the EL or ARL, the mean difference being –0.23 mm ± 0.32 (P < 0.05). Conclusions It was concluded that the Tri Auto ZX was useful and reliable. The Tri Auto ZX measurements protected against overpreparation.