Interchangeability, accuracy, and precision of a handheld blood lactate analyzer across low to high exercise intensities
Open Access
- 5 January 2026
- journal article
- research article
- Published by Springer Nature in Sport Sciences for Health
- Vol. 22 (1) , 34
Abstract
Purpose: To assess: (1) within-brand differences and interchangeability of the TaiDoc TD-4289 analyzer, by evaluating the measured blood lactate concentrations across ten units of this analyzer; (2) the accuracy and precision of the analyzer using newly developed strips that present lactate concentrations on a different scale. Methods: Venous blood samples were taken at relevant exercise intensities. The blood lactate concentration was measured simultaneously with different units of TaiDoc TD-4289. In the first test, 400 measurements of blood lactate using original strips of code 546 were performed (four intensities times 10 measurement series times 10 units). The within-brand analysis used a modified mean excluding the minimum, maximum, and considered value in each measurement series as reference. In the second test, 64 measurements of blood lactate using newly developed strips of code 335 were performed (eight measurements series times eight units). The measurements were compared to a reference analyzer (YSI Sport 1500) to determine the accuracy and precision when using the code 335 strips. Results: Within-brand differences were non-significant; all 10 units were within an absolute mean relative difference to the modified mean of 1.8%. When using code 335 strips, the mean relative difference to the reference analyzer was 45% and the residual standard error was 0.097 mM. Conclusion: The TaiDoc TD-4289 analyzer demonstrated high degree of within-brand interchangeability. Using the new code 335 strips, its accuracy was comparable to other established analyzers, while the precision was considerably better than what we have previously found with other commonly used handheld lactate analyzers.Keywords
Funding Information
- Norwegian School Of Sport Sciences - The Library
This publication has 12 references indexed in Scilit:
- Comparison of lactate measurements from earlobe and fingertip capillary blood using Biosen S-Line and lactate scout analyzersEuropean Journal of Applied Physiology, 2024
- Precision and accuracy of four handheld blood lactate analyzers across low to high exercise intensitiesEuropean Journal of Applied Physiology, 2024
- Training Session Models in Endurance Sports: A Norwegian Perspective on Best Practice RecommendationsSports Medicine, 2024
- Three Norwegian brothers all European 1500 m champions: What is the secret?International Journal of Sports Science & Coaching, 2019
- Manipulating graded exercise test variables affects the validity of the lactate threshold and V˙O2peakPLOS ONE, 2018
- Effects of Varying the Step Duration on the Determination of Lactate Thresholds in Elite RowersInternational Journal of Sports Physiology and Performance, 2018
- Biological Variation in Variables Associated with Exercise TrainingInternational Journal of Sports Medicine, 2003
- Effects of time, temperature and blood cell counts on levels of lactate in heparinized whole blood gas samplesScandinavian Journal of Clinical and Laboratory Investigation, 2003
- Lactate concentration differences in plasma, whole blood, capillary finger blood and erythrocytes during submaximal graded exercise in humansEuropean Journal of Applied Physiology, 1990
- Lactate determination with the lactate analyser LA 640: a critical studyScandinavian Journal of Clinical and Laboratory Investigation, 1985