Thomas Losnegard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas Losnegard has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Bjarne Rud
Department of Physical Performance, The Norwegian School of Sport Sciences, Oslo, Norway
6 shared publicationsMagne Lund-Hansen
Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
6 shared publicationsHåvard Myklebust
Department of Physical Performance, Norwegian School of Sport Sciences, Ullevål Stadion, Post Box 4014, 0806, Oslo, Norway
5 shared publications- Fredrik Mentzoni
The Norwegian Olympic Sports Center, The Norwegian Olympic and Paralympic Committee and Confederation of Sports, Oslo, Norway
4 shared publications Jan Kocbach
Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Sciences, Center for Elite Sports Research, Norwegian University of Science and Technology, Trondheim, Norway
4 shared publicationsJostein Hallén
A Department of Physical Performance , Norwegian School of Sport Sciences , Oslo , Norway
4 shared publications
Latest Publications
- Open Access
- 11 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Agreement between official race data and a high-end sports tracker for a Paralympic rower
Race data containing speed and stroke rate per 50m, provided by World Rowing, were compared with measurements using an ASI AdMos sensor, which is a high-end sports tracker, to assess the agreement between the two measurement systems. Twelve races in 2022, 2023, and 2024 were considered. All measurements were of the same rower competing in the Paralympic PR1 W1x class. The race data speed was compared with speed calculated from the GNSS data of the AdMos sensor, while stroke rate was compared with the stroke rate calculated from the surge acceleration of the IMU data of the AdMos sensor. Comparisons were made for each 50m segment. Additionally, official 500m split times were used to assess the accuracy of both the race data and the AdMos measurements. The absolute difference between the race data and the AdMos measurements was within rounding tolerance in 312 of 480 segments (65%) for speed and 410 of 480 segments (85%) for stroke rate. The comparison of mean speed per 50m segment revealed a mean absolute difference (MAD) of 0.05ms $$^{-1}$$ (mean absolute relative difference: 1.6%). The speed difference was largest in the first 50m of the race, with a MAD equal to 0.39ms $$^{-1}$$ (12%). If comparing the race data with the AdMos speed of the last stroke before each segment end, the difference in the first 50m reduced to 0.12ms $$^{-1}$$ (3.3%). The MAD in stroke rate was 0.3 strokes per minute (1.0%). Compared to the official 500m split times, the MAD of the AdMos was 0.3s (0.2%), whereas calculation of the 500m splits from the race data yielded a MAD equal to 1.0s (0.7%). World Rowing’s official 50m race data showed good agreement with the high-end sports tracker in most segments, but the systems diverged considerably for speed in the first segment. Practitioners should verify data characteristics before using official race data for high-precision biomechanical or pacing analyses.- 11 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessAgreement between official race data and a high-end sports tracker for a Paralympic rower
Race data containing speed and stroke rate per 50m, provided by World Rowing, were compared with measurements using an ASI AdMos sensor, which is a high-end sports tracker, to assess the agreement between the two measurement systems. Twelve races in 2022, 2023, and 2024 were considered. All measurements were of the same rower competing in the Paralympic PR1 W1x class. The race data speed was compared with speed calculated from the GNSS data of the AdMos sensor, while stroke rate was compared with the stroke rate calculated from the surge acceleration of the IMU data of the AdMos sensor. Comparisons were made for each 50m segment. Additionally, official 500m split times were used to assess the accuracy of both the race data and the AdMos measurements. The absolute difference between the race data and the AdMos measurements was within rounding tolerance in 312 of 480 segments (65%) for speed and 410 of 480 segments (85%) for stroke rate. The comparison of mean speed per 50m segment revealed a mean absolute difference (MAD) of 0.05ms $$^{-1}$$ (mean absolute relative difference: 1.6%). The speed difference was largest in the first 50m of the race, with a MAD equal to 0.39ms $$^{-1}$$ (12%). If comparing the race data with the AdMos speed of the last stroke before each segment end, the difference in the first 50m reduced to 0.12ms $$^{-1}$$ (3.3%). The MAD in stroke rate was 0.3 strokes per minute (1.0%). Compared to the official 500m split times, the MAD of the AdMos was 0.3s (0.2%), whereas calculation of the 500m splits from the race data yielded a MAD equal to 1.0s (0.7%). World Rowing’s official 50m race data showed good agreement with the high-end sports tracker in most segments, but the systems diverged considerably for speed in the first segment. Practitioners should verify data characteristics before using official race data for high-precision biomechanical or pacing analyses. - Open Access
- 30 March 2026
- Published by Springer Nature in Sport Sciences for Health
- Vol. 22 (2)
The influence of competition-specific endurance priming on sprint time-trial performance in cross-country skiing
Purpose: This study investigated the influence of including a competition-specific high-intensity endurance priming bout during warm-up on sprint time-trial (TT) performance in roller-ski skating among cross-country (XC) skiers. Methods: Twelve national-level XC skiers (2 women) completed two different warm-up protocols in counterbalanced order on two consecutive days. At each test day, the warm-ups were followed by two 1.2-km sprint TTs (TT1 and TT2) separated by 30 min of active recovery. Both warm-up protocols consisted of five laps at low to moderate intensities followed by a final lap including either a ~ 2-min high-intensity competition-specific priming (PRIM) or low-intensity exercise (TRAD). Speed and heart rate (HR) were measured continuously while rating of perceived exertion (RPE; Borg 6–20), perceived readiness and technical quality (scale 1–10) were assessed after warm-ups and TTs. After day two, participants rated how they perceived each warm-up in preparing them for performance. Results: Performance did not differ between TRAD and PRIM in TT1 (169.8 ± 18.4 vs. 169.6 ± 17.2 s, P = .885) or TT2 (166.6 ± 16.1 vs. 168.9 ± 16.8 s, P = .105). Within TRAD, performance improved in TT2 vs. TT1 (166.6 ± 16.1 vs. 169.8 ± 18.4 s, P = .008), accompanied with higher HR (175 ± 6 vs. 173 ± 6 beats·min⁻ 1 , P = .005), RPE (18.7 ± 0.9 vs. 18.0 ± 0.9, P = .033) and perceived technical quality (7.7 ± 1.0 vs. 6.8 ± 1.4, P = .031). No differences between TTs were observed within PRIM. Athletes perceived PRIM as more beneficial in preparing them to perform than TRAD (8.0 ± 1.5 vs. 4.6 ± 1.6, P = .003). Conclusion: Including a competition-specific high-intensity priming bout during warm-up did not enhance sprint TT performance compared to a traditional warm-up but was perceived as more beneficial in preparing the skiers to perform.
- 30 March 2026
- Published by Springer Nature in Sport Sciences for Health
- Vol. 22 (2)
Open AccessThe influence of competition-specific endurance priming on sprint time-trial performance in cross-country skiing
Purpose: This study investigated the influence of including a competition-specific high-intensity endurance priming bout during warm-up on sprint time-trial (TT) performance in roller-ski skating among cross-country (XC) skiers. Methods: Twelve national-level XC skiers (2 women) completed two different warm-up protocols in counterbalanced order on two consecutive days. At each test day, the warm-ups were followed by two 1.2-km sprint TTs (TT1 and TT2) separated by 30 min of active recovery. Both warm-up protocols consisted of five laps at low to moderate intensities followed by a final lap including either a ~ 2-min high-intensity competition-specific priming (PRIM) or low-intensity exercise (TRAD). Speed and heart rate (HR) were measured continuously while rating of perceived exertion (RPE; Borg 6–20), perceived readiness and technical quality (scale 1–10) were assessed after warm-ups and TTs. After day two, participants rated how they perceived each warm-up in preparing them for performance. Results: Performance did not differ between TRAD and PRIM in TT1 (169.8 ± 18.4 vs. 169.6 ± 17.2 s, P = .885) or TT2 (166.6 ± 16.1 vs. 168.9 ± 16.8 s, P = .105). Within TRAD, performance improved in TT2 vs. TT1 (166.6 ± 16.1 vs. 169.8 ± 18.4 s, P = .008), accompanied with higher HR (175 ± 6 vs. 173 ± 6 beats·min⁻ 1 , P = .005), RPE (18.7 ± 0.9 vs. 18.0 ± 0.9, P = .033) and perceived technical quality (7.7 ± 1.0 vs. 6.8 ± 1.4, P = .031). No differences between TTs were observed within PRIM. Athletes perceived PRIM as more beneficial in preparing them to perform than TRAD (8.0 ± 1.5 vs. 4.6 ± 1.6, P = .003). Conclusion: Including a competition-specific high-intensity priming bout during warm-up did not enhance sprint TT performance compared to a traditional warm-up but was perceived as more beneficial in preparing the skiers to perform.
- Open Access
- 5 January 2026
- Published by Springer Nature in Sport Sciences for Health
- Vol. 22 (1) , 34
Interchangeability, accuracy, and precision of a handheld blood lactate analyzer across low to high exercise intensities
Purpose: To assess: (1) within-brand differences and interchangeability of the TaiDoc TD-4289 analyzer, by evaluating the measured blood lactate concentrations across ten units of this analyzer; (2) the accuracy and precision of the analyzer using newly developed strips that present lactate concentrations on a different scale. Methods: Venous blood samples were taken at relevant exercise intensities. The blood lactate concentration was measured simultaneously with different units of TaiDoc TD-4289. In the first test, 400 measurements of blood lactate using original strips of code 546 were performed (four intensities times 10 measurement series times 10 units). The within-brand analysis used a modified mean excluding the minimum, maximum, and considered value in each measurement series as reference. In the second test, 64 measurements of blood lactate using newly developed strips of code 335 were performed (eight measurements series times eight units). The measurements were compared to a reference analyzer (YSI Sport 1500) to determine the accuracy and precision when using the code 335 strips. Results: Within-brand differences were non-significant; all 10 units were within an absolute mean relative difference to the modified mean of 1.8%. When using code 335 strips, the mean relative difference to the reference analyzer was 45% and the residual standard error was 0.097 mM. Conclusion: The TaiDoc TD-4289 analyzer demonstrated high degree of within-brand interchangeability. Using the new code 335 strips, its accuracy was comparable to other established analyzers, while the precision was considerably better than what we have previously found with other commonly used handheld lactate analyzers.
- 5 January 2026
- Published by Springer Nature in Sport Sciences for Health
- Vol. 22 (1) , 34
Open AccessInterchangeability, accuracy, and precision of a handheld blood lactate analyzer across low to high exercise intensities
Purpose: To assess: (1) within-brand differences and interchangeability of the TaiDoc TD-4289 analyzer, by evaluating the measured blood lactate concentrations across ten units of this analyzer; (2) the accuracy and precision of the analyzer using newly developed strips that present lactate concentrations on a different scale. Methods: Venous blood samples were taken at relevant exercise intensities. The blood lactate concentration was measured simultaneously with different units of TaiDoc TD-4289. In the first test, 400 measurements of blood lactate using original strips of code 546 were performed (four intensities times 10 measurement series times 10 units). The within-brand analysis used a modified mean excluding the minimum, maximum, and considered value in each measurement series as reference. In the second test, 64 measurements of blood lactate using newly developed strips of code 335 were performed (eight measurements series times eight units). The measurements were compared to a reference analyzer (YSI Sport 1500) to determine the accuracy and precision when using the code 335 strips. Results: Within-brand differences were non-significant; all 10 units were within an absolute mean relative difference to the modified mean of 1.8%. When using code 335 strips, the mean relative difference to the reference analyzer was 45% and the residual standard error was 0.097 mM. Conclusion: The TaiDoc TD-4289 analyzer demonstrated high degree of within-brand interchangeability. Using the new code 335 strips, its accuracy was comparable to other established analyzers, while the precision was considerably better than what we have previously found with other commonly used handheld lactate analyzers.
- Open Access
- 5 January 2026
- Published by Springer Nature in Sport Sciences for Health
- Vol. 22 (1) , 25
Self-regulated pacing in biathlon: how shooting impacts skiing strategy compared to cross-country skiing
Purpose: Biathlon, a unique combination of cross-country skiing and precision rifle shooting, offers an intriguing subject for the study of pacing behavior. We examined the impact of shooting on pacing behavior in highly trained biathletes. Methods: Twenty senior biathletes completed one biathlon and one cross-country skiing trial on separate days in a randomized order. Both trials covered a distance of 7.5 km (3 × 2.5 km for women) or 10 km (3 × 3.3 km for men) on rollerskies. During biathlon, shooting after lap 1 (prone) and lap 2 (standing) was conducted. Time, speed profiles, heart rate (HR), ratings of perceived exertion (RPE), and pre and post pacing questionnaires (4- and 6-point scales) were compared between conditions. Results: During cross-country skiing, athletes were faster overall (mean ± 95%CI; −6.5 ± 1.2% and -1.5 ± 1.0%, including and excluding shooting, respectively), which was attributed to a reduction in speed in the last ~ 60 s prior to shooting. No significant differences were found in HR or RPE, except after shooting. The athletes recognized the importance of shooting in their race strategy (Mdn = 5, IQR = 1.1) and reported an intentional reduction in exercise intensity before prone and standing shooting. Conclusions: The act of shooting influences the pacing behavior in biathlon as evidenced by decrease in speed ⁓60 s prior to shooting, while maintaining similar pacing elsewhere. Moreover, the pacing behavior align better with pre-trial goals compared to cross-country skiing. No significant differences were observed in HR or RPE during the race, suggesting that the overall effort did not differ between disciplines.
- 5 January 2026
- Published by Springer Nature in Sport Sciences for Health
- Vol. 22 (1) , 25
Open AccessSelf-regulated pacing in biathlon: how shooting impacts skiing strategy compared to cross-country skiing
Purpose: Biathlon, a unique combination of cross-country skiing and precision rifle shooting, offers an intriguing subject for the study of pacing behavior. We examined the impact of shooting on pacing behavior in highly trained biathletes. Methods: Twenty senior biathletes completed one biathlon and one cross-country skiing trial on separate days in a randomized order. Both trials covered a distance of 7.5 km (3 × 2.5 km for women) or 10 km (3 × 3.3 km for men) on rollerskies. During biathlon, shooting after lap 1 (prone) and lap 2 (standing) was conducted. Time, speed profiles, heart rate (HR), ratings of perceived exertion (RPE), and pre and post pacing questionnaires (4- and 6-point scales) were compared between conditions. Results: During cross-country skiing, athletes were faster overall (mean ± 95%CI; −6.5 ± 1.2% and -1.5 ± 1.0%, including and excluding shooting, respectively), which was attributed to a reduction in speed in the last ~ 60 s prior to shooting. No significant differences were found in HR or RPE, except after shooting. The athletes recognized the importance of shooting in their race strategy (Mdn = 5, IQR = 1.1) and reported an intentional reduction in exercise intensity before prone and standing shooting. Conclusions: The act of shooting influences the pacing behavior in biathlon as evidenced by decrease in speed ⁓60 s prior to shooting, while maintaining similar pacing elsewhere. Moreover, the pacing behavior align better with pre-trial goals compared to cross-country skiing. No significant differences were observed in HR or RPE during the race, suggesting that the overall effort did not differ between disciplines.
- Open Access
- 4 June 2025
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 125 (7) , 2023-2026
Correction: Test–retest reliability of performance variables during treadmill rollerski skating
- 4 June 2025
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 125 (7) , 2023-2026
Open AccessCorrection: Test–retest reliability of performance variables during treadmill rollerski skating
- Open Access
- 24 May 2025
- Published by Springer Nature in Sport Sciences for Health
- p. 1-13
Sex differences in classical and skating cross-country skiing time-trial competitions
Purpose: To compare differences in speed, sub-technique selection, and kinematics between male and female cross-country skiers during 10-km time-trial competitions. Methods: Elite- to world-class skiers performed FIS-regulated 3 × 3.3-km classical (12 women, 22 men) and skating (15 women, 32 men) competitions. A combined GNSS and IMU unit were used to determine speed, sub-technique selection, and kinematics. Results: Average speeds for men were 12% higher than for women in both styles (both P < .001), with no differences between laps, indicating similar lap-to-lap pacing. Men demonstrated 18, 10, and 5% higher speeds in uphill, flat, and downhill terrains, respectively, for classical and 17, 6, and 5% for skating (all P < .05). Further, men spent 3%-point less of their relative time in uphill and correspondingly more time in flat and downhill terrain (all P < .001). In classical, men spent ⁓10%-point more of their total time in double poling and corresponding ⁓9%-point less time in diagonal than women (both P < .001). In skating, men spent ⁓9%-point more of their total time in the Gear-3 and ⁓12%-point less time in the Gear-2 sub-technique (all P < .001). This was accompanied by ⁓7–19% longer cycle lengths in both styles for men compared to women (all P < .05). Conclusion: Average performance differences between sexes in classical and skating cross-country skiing time trials are around 12% but highly terrain dependent, with the largest sex differences in uphill terrain. These distinct competitive demands between sexes, including more time spent in uphill terrain and more use of “low-speed gears” in women, highlight a potential need for sex-specific training strategies.
- 24 May 2025
- Published by Springer Nature in Sport Sciences for Health
- p. 1-13
Open AccessSex differences in classical and skating cross-country skiing time-trial competitions
Purpose: To compare differences in speed, sub-technique selection, and kinematics between male and female cross-country skiers during 10-km time-trial competitions. Methods: Elite- to world-class skiers performed FIS-regulated 3 × 3.3-km classical (12 women, 22 men) and skating (15 women, 32 men) competitions. A combined GNSS and IMU unit were used to determine speed, sub-technique selection, and kinematics. Results: Average speeds for men were 12% higher than for women in both styles (both P < .001), with no differences between laps, indicating similar lap-to-lap pacing. Men demonstrated 18, 10, and 5% higher speeds in uphill, flat, and downhill terrains, respectively, for classical and 17, 6, and 5% for skating (all P < .05). Further, men spent 3%-point less of their relative time in uphill and correspondingly more time in flat and downhill terrain (all P < .001). In classical, men spent ⁓10%-point more of their total time in double poling and corresponding ⁓9%-point less time in diagonal than women (both P < .001). In skating, men spent ⁓9%-point more of their total time in the Gear-3 and ⁓12%-point less time in the Gear-2 sub-technique (all P < .001). This was accompanied by ⁓7–19% longer cycle lengths in both styles for men compared to women (all P < .05). Conclusion: Average performance differences between sexes in classical and skating cross-country skiing time trials are around 12% but highly terrain dependent, with the largest sex differences in uphill terrain. These distinct competitive demands between sexes, including more time spent in uphill terrain and more use of “low-speed gears” in women, highlight a potential need for sex-specific training strategies.
- Open Access
- 27 March 2025
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 125 (7) , 2015-2021
Test–retest reliability of performance variables during treadmill rollerski skating
Purpose: We examined the test–retest reliability of rollerski testing across a familiarization trial followed by three separate test trials (T1–T3) conducted within a 14-day period. Methods: Ten competitive cross-country skiers performed three sub-maximal tests (5%, speed range 10–16 km h−1) and a maximal speed test until failure (MTF; ~ 5–8 min, 7%, > 10 km h−1) on a rollerski treadmill using the Gear 3 ski skating sub-technique. Reliability was assessed as within-subject typical error, expressed as a coefficient of variation (CV%, [confidence limits]) intraclass correlation (ICC, [confidence limits]), and changes in mean (%). Results: The speed at MTF demonstrated a mean CV (T1–T3) of 1.5% [1.1, 2.6] and an ICC of 0.96 [0.87, 0.99], but a systematic familiarization bias from T1 to T2 (1.2% [0.1, 2.3]) and T2 to T3 (2.2% [0.1, 4.3]). Peak oxygen uptake exhibited a mean CV of 2.2% [1.6, 3.8] and an ICC of 0.93 [0.78, 0.98], with no systematic changes from T1 to T2 (− 0.2% [− 2.0, 1.6]) and T2 to T3 (1.8% [− 1.1, 4.7]). VO2 at submaximal load showed a mean CV of 2.1% [1.5, 3.3] and an ICC of 0.94 [0.84,0.99], with no systematic changes from T1 to T2 (− 0.7% [− 2.4, 1.1]) and T2 to T3 (− 0.1% [− 2.4, 2.3]). Conclusion: The relatively low CV and high ICC for most measures suggest a high degree of test–retest reliability. However, the systematic mean changes in MTF indicate that familiarization trials are essential to provide valuable information about individual changes. Overall, these reliability measures can be used as a framework by practitioners to discern true changes when testing on a rollerski treadmill.
- 27 March 2025
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 125 (7) , 2015-2021
Open AccessTest–retest reliability of performance variables during treadmill rollerski skating
Purpose: We examined the test–retest reliability of rollerski testing across a familiarization trial followed by three separate test trials (T1–T3) conducted within a 14-day period. Methods: Ten competitive cross-country skiers performed three sub-maximal tests (5%, speed range 10–16 km h−1) and a maximal speed test until failure (MTF; ~ 5–8 min, 7%, > 10 km h−1) on a rollerski treadmill using the Gear 3 ski skating sub-technique. Reliability was assessed as within-subject typical error, expressed as a coefficient of variation (CV%, [confidence limits]) intraclass correlation (ICC, [confidence limits]), and changes in mean (%). Results: The speed at MTF demonstrated a mean CV (T1–T3) of 1.5% [1.1, 2.6] and an ICC of 0.96 [0.87, 0.99], but a systematic familiarization bias from T1 to T2 (1.2% [0.1, 2.3]) and T2 to T3 (2.2% [0.1, 4.3]). Peak oxygen uptake exhibited a mean CV of 2.2% [1.6, 3.8] and an ICC of 0.93 [0.78, 0.98], with no systematic changes from T1 to T2 (− 0.2% [− 2.0, 1.6]) and T2 to T3 (1.8% [− 1.1, 4.7]). VO2 at submaximal load showed a mean CV of 2.1% [1.5, 3.3] and an ICC of 0.94 [0.84,0.99], with no systematic changes from T1 to T2 (− 0.7% [− 2.4, 1.1]) and T2 to T3 (− 0.1% [− 2.4, 2.3]). Conclusion: The relatively low CV and high ICC for most measures suggest a high degree of test–retest reliability. However, the systematic mean changes in MTF indicate that familiarization trials are essential to provide valuable information about individual changes. Overall, these reliability measures can be used as a framework by practitioners to discern true changes when testing on a rollerski treadmill.
- 1 January 2025
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- Vol. 20 (1) , 4-16
Pacing Demands in Competitive Nordic Skiing
Background and Purpose: Cross-country skiing, biathlon, and Nordic combined are Winter Olympics sports that involve cross-country skiing in undulating terrain, characterized by various subtechniques and repeated intensity fluctuations. The stochastic interval profile of these sports necessitates the continuous regulation of work and energy expenditure throughout training sessions and competitions, a concept known as pacing. With the advent of technological advancements that allow for the measurement of these features during training and competitions, scientific studies have broadened our understanding of the associated racing and pacing demands. We provide the current scientific overview of pacing demands in competitive cross-country skiing, biathlon, and Nordic combined and propose guidelines for how performance can be enhanced by adjusting pacing behavior. Conclusions and Practical Applications: The study of pacing in skiing has evolved from basic lap-to-lap, or segment, analyses to detailed insights into micropacing strategies. This includes analysis of speed, internal and external power, subtechnique distribution, and associated temporal patterns, combined with subjective ratings of effort. While several objective tools such as heart rate, blood lactate concentration, and speed measurements are widely used in practice, current understanding suggests that these measures should supplement, rather than replace, the use of perceived effort (eg, rating of perceived exertion) to regulate intensity during training and competition in undulating terrain. Therefore, the ability to self-regulate effort appears to be an important performance characteristic and should be developed in adolescents and systematically used to optimize and evaluate the training process and race performance throughout athletes’ careers.
- 1 January 2025
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- Vol. 20 (1) , 4-16
Pacing Demands in Competitive Nordic Skiing
Background and Purpose: Cross-country skiing, biathlon, and Nordic combined are Winter Olympics sports that involve cross-country skiing in undulating terrain, characterized by various subtechniques and repeated intensity fluctuations. The stochastic interval profile of these sports necessitates the continuous regulation of work and energy expenditure throughout training sessions and competitions, a concept known as pacing. With the advent of technological advancements that allow for the measurement of these features during training and competitions, scientific studies have broadened our understanding of the associated racing and pacing demands. We provide the current scientific overview of pacing demands in competitive cross-country skiing, biathlon, and Nordic combined and propose guidelines for how performance can be enhanced by adjusting pacing behavior. Conclusions and Practical Applications: The study of pacing in skiing has evolved from basic lap-to-lap, or segment, analyses to detailed insights into micropacing strategies. This includes analysis of speed, internal and external power, subtechnique distribution, and associated temporal patterns, combined with subjective ratings of effort. While several objective tools such as heart rate, blood lactate concentration, and speed measurements are widely used in practice, current understanding suggests that these measures should supplement, rather than replace, the use of perceived effort (eg, rating of perceived exertion) to regulate intensity during training and competition in undulating terrain. Therefore, the ability to self-regulate effort appears to be an important performance characteristic and should be developed in adolescents and systematically used to optimize and evaluate the training process and race performance throughout athletes’ careers.
- Open Access
- 19 August 2024
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 124 (12) , 3781-3788
Precision and accuracy of four handheld blood lactate analyzers across low to high exercise intensities
Purpose: To evaluate the precision and accuracy in measured blood lactate concentrations among four commonly used handheld lactate analyzers compared to two stationary analyzers. Methods: Venous blood samples were taken at exercise intensities ranging from low to high. The blood lactate concentration was measured simultaneously with four pairs of handheld lactate analyzers (two new units of each brand: Lactate Plus, Lactate Pro2, Lactate Scout 4, and TaiDoc TD-4289), and compared with two stationary analyzers (Biosen C-Line and YSI Sport 1500). Measurements were repeated for a range of blood lactate concentrations (measured with Biosen) from 0.88 to 4.89 mM with a median difference between measurements of 0.10 mM. Results: The mean relative differences to the Biosen analyzer were $$-$$ 7% (Plus), 7% (Pro), $$-$$ 10% (Scout), 42% (Tai), and $$-$$ 32% (Ysi). The residual standard errors after linear regression against Biosen were 0.18 mM (Plus), 0.20 mM (Pro), 0.22 mM (Scout), 0.15 mM (Tai), and 0.06 mM (Ysi). Accordingly, a blood lactate concentration of 3 mM measured with Biosen yielded 95% prediction intervals that were 0.72 mM (Plus), 0.80 mM (Pro), 0.87 mM (Scout), 0.60 mM (Tai), and 0.23 mM (Ysi) wide. Conclusion: Compared to our two stationary analyzers, the precision of the four handheld lactate analyzers evaluated in this study was poor. Among the four, Tai was the most precise; however, this analyzer had low accuracy with a substantial mean difference to the reference analyzer.- 19 August 2024
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 124 (12) , 3781-3788
Open AccessPrecision and accuracy of four handheld blood lactate analyzers across low to high exercise intensities
Purpose: To evaluate the precision and accuracy in measured blood lactate concentrations among four commonly used handheld lactate analyzers compared to two stationary analyzers. Methods: Venous blood samples were taken at exercise intensities ranging from low to high. The blood lactate concentration was measured simultaneously with four pairs of handheld lactate analyzers (two new units of each brand: Lactate Plus, Lactate Pro2, Lactate Scout 4, and TaiDoc TD-4289), and compared with two stationary analyzers (Biosen C-Line and YSI Sport 1500). Measurements were repeated for a range of blood lactate concentrations (measured with Biosen) from 0.88 to 4.89 mM with a median difference between measurements of 0.10 mM. Results: The mean relative differences to the Biosen analyzer were $$-$$ 7% (Plus), 7% (Pro), $$-$$ 10% (Scout), 42% (Tai), and $$-$$ 32% (Ysi). The residual standard errors after linear regression against Biosen were 0.18 mM (Plus), 0.20 mM (Pro), 0.22 mM (Scout), 0.15 mM (Tai), and 0.06 mM (Ysi). Accordingly, a blood lactate concentration of 3 mM measured with Biosen yielded 95% prediction intervals that were 0.72 mM (Plus), 0.80 mM (Pro), 0.87 mM (Scout), 0.60 mM (Tai), and 0.23 mM (Ysi) wide. Conclusion: Compared to our two stationary analyzers, the precision of the four handheld lactate analyzers evaluated in this study was poor. Among the four, Tai was the most precise; however, this analyzer had low accuracy with a substantial mean difference to the reference analyzer. - Open Access
- 25 June 2024
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 124 (11) , 3337-3349
The influence of race duration on oxygen demand, uptake and deficit in competitive cross-country skiers
Purpose: To measure oxygen demand, uptake, and deficits in competitive cross-country skiers during outdoor roller skiing at different competition durations, ranging from the endurance domain to the sprint domain. Methods: Ten competitive cross-country skiers (6 males; $$\dot{\text{V}}$$ O2max 78 ± 3 and 4 females; $$\dot{\text{V}}$$ O2max 62 ± 3 mL∙kg−1∙min−1) raced time trials consisting of 1, 2, and 4 laps in a 1.6 km racecourse in a randomized order with 35 min recovery in-between. Oxygen uptake was measured using a wearable metabolic system while oxygen demand was estimated from kinematic data (GPS and IMU) and an athlete-specific model of skiing economy. Skiing economy and $$\dot{\text{V}}$$ O2max was established on a separate test day using six submaximal constant-load trials at different speeds and inclines, and one maximal-effort trial on a roller-skiing treadmill. Results: Average oxygen demand was 112 ± 8%, 103 ± 7% and 98 ± 7% of $$\dot{\text{V}}$$ O2max during the 1 (3:37 ± 0:20 m:ss), 2 (7:36 ± 0:38 m:ss) and 4 (15:43 ± 1:26 m:ss) lap time trials, respectively, and appeared to follow an inverse relationship with time-trial duration. Average oxygen uptake was unaffected by race length (86 ± 5%, 86 ± 5%, and 86 ± 7% of $$\dot{\text{V}}$$ O2max, respectively). Accumulated oxygen deficit at the end of each time trial was 85 ± 13, 106 ± 32 and 158 ± 62 mL∙kg−1, while oxygen deficits per work bout was 23 ± 3, 18 ± 3 and 16 ± 3 mL∙kg−1 for the 1, 2, and 4-lap time trials, respectively. Conclusion: Elite cross-country skiers adjust their pacing strategies from attaining relatively small oxygen deficits per work bout in the endurance domain, to larger deficits in the sprint domain. This indicates a shift in strategy from prioritizing stable work-economy and rate-of-recovery in the endurance domain, to maximizing power output in the sprint domain.- 25 June 2024
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 124 (11) , 3337-3349
Open AccessThe influence of race duration on oxygen demand, uptake and deficit in competitive cross-country skiers
Purpose: To measure oxygen demand, uptake, and deficits in competitive cross-country skiers during outdoor roller skiing at different competition durations, ranging from the endurance domain to the sprint domain. Methods: Ten competitive cross-country skiers (6 males; $$\dot{\text{V}}$$ O2max 78 ± 3 and 4 females; $$\dot{\text{V}}$$ O2max 62 ± 3 mL∙kg−1∙min−1) raced time trials consisting of 1, 2, and 4 laps in a 1.6 km racecourse in a randomized order with 35 min recovery in-between. Oxygen uptake was measured using a wearable metabolic system while oxygen demand was estimated from kinematic data (GPS and IMU) and an athlete-specific model of skiing economy. Skiing economy and $$\dot{\text{V}}$$ O2max was established on a separate test day using six submaximal constant-load trials at different speeds and inclines, and one maximal-effort trial on a roller-skiing treadmill. Results: Average oxygen demand was 112 ± 8%, 103 ± 7% and 98 ± 7% of $$\dot{\text{V}}$$ O2max during the 1 (3:37 ± 0:20 m:ss), 2 (7:36 ± 0:38 m:ss) and 4 (15:43 ± 1:26 m:ss) lap time trials, respectively, and appeared to follow an inverse relationship with time-trial duration. Average oxygen uptake was unaffected by race length (86 ± 5%, 86 ± 5%, and 86 ± 7% of $$\dot{\text{V}}$$ O2max, respectively). Accumulated oxygen deficit at the end of each time trial was 85 ± 13, 106 ± 32 and 158 ± 62 mL∙kg−1, while oxygen deficits per work bout was 23 ± 3, 18 ± 3 and 16 ± 3 mL∙kg−1 for the 1, 2, and 4-lap time trials, respectively. Conclusion: Elite cross-country skiers adjust their pacing strategies from attaining relatively small oxygen deficits per work bout in the endurance domain, to larger deficits in the sprint domain. This indicates a shift in strategy from prioritizing stable work-economy and rate-of-recovery in the endurance domain, to maximizing power output in the sprint domain.