Indoor air quality analysis in naturally ventilated university training laboratories: a health risk assessment
Authors:
- Susana SeseñaSSSusana Seseña
- RodríguezRORodríguez
- Ana M.AMAna M.
- M. Llanos PalopMPM. Llanos Palop
Open Access
- 9 July 2022
- journal article
- research article
- Published by Springer Nature in Air Quality, Atmosphere & Health
- Vol. 15 (10) , 1817-1837
Abstract
The indoor air quality (IAQ) of eleven naturally ventilated training laboratories was analysed to evaluate the health risk to occupants. IAQ evaluation included analysis of physical (temperature (T) and relative humidity (RH)), chemical (CO2, CO, O3, total volatile organic compounds (TVOC), and particulate matter (PM)) and microbiological (fungi and bacteria) pollutants. Monitoring was carried out in labs used for teaching different academic disciplines (biology, chemical, ecology, and computers) during two periods of the academic year. Ventilation rates (VR), air change per hour (ACH) in every lab, and the hazard quotients for each of the chemical pollutants and the accumulated (HQ and HI) were calculated. Environmental comfort was not fully satisfactory considering the RH and CO2 values, especially during hours with higher occupancy. Coarse particles and bacteria were generated indoor related to human activity. At chemical and biological laboratories, TVOC concentrations were sometimes above the recommended value, and all the labs presented VR below the European guideline’s recommendations. Results from this study show natural ventilation is not enough to get an adequate IAQ, although no significant non-carcinogenic risk was estimated. However, installation of complementary ventilation systems would be advisable to avoid health risk by acute short-term exposure. Graphical abstractKeywords
Funding Information
- Universidad de Castilla-La Mancha (GRIN-31098)
- Universidad de Castilla la Mancha
This publication has 73 references indexed in Scilit:
- Quantitative relationships between occupant satisfaction and satisfaction aspects of indoor environmental quality and building designIndoor Air, 2011
- Indoor air pollution and childhood asthma: variations between urban and rural areasIndoor Air, 2010
- Indoor air quality in university environmentsEnvironmental Monitoring and Assessment, 2009
- Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC systemEnvironmental Monitoring and Assessment, 2009
- Survey of Airborne Bacterial Genus at a University CampusIndoor and Built Environment, 2008
- Indoor Air Quality Measurements in the Chemistry Department Building of the University of AthensIndoor and Built Environment, 2006
- Atmospheric Aerosols: Composition, Transformation, Climate and Health EffectsAngewandte Chemie International Edition, 2005
- Size-selective assessment of airborne particles in swine confinement building with the UVAPSAtmospheric Environment, 2004
- Characterization of Particulate Emissions from Occupant Activities in OfficesIndoor Air, 2001
- Determination of Selected Pollutants and Measurement of Physical Parameters for the Evaluation of Indoor Air Quality in School Buildings in Athens, GreeceIndoor and Built Environment, 2001