Imaging electrical excitation inside the myocardial wall
Open Access
- 16 February 2011
- journal article
- research article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 2 (3) , 620-633
Abstract
Cardiac arrhythmias are often triggered by ectopic membrane depolarization originating deep inside the myocardial wall. Here we propose a new method utilizing a novel near-infrared voltage-sensitive fluorescent dye DI-4-ANBDQBS to determine the three-dimensional (3D) coordinates of the sources of such depolarization. We tested the method in live preparations of pig left and right ventricular myocardium (thickness 8-18 mm) and phantoms imitating the optical properties of myocardial tissue. The method utilizes an alternating transillumination approach that involves comparing pairs of simultaneously recorded broad-field epifluorescence and transillumination images produced at two alternating directions of illumination. Recordings were taken simultaneously by two CCD cameras facing the endocardial and epicardial surfaces of the heart at a frame rate up to 3 KHz. In live preparations, we were able to localize the origin of the depolarization wave with a precision of ±1.3mm in the transmural direction and 3 mm in the image plane. The accuracy of detection was independent of the depth of the source inside ventricular wall.Keywords
This publication has 25 references indexed in Scilit:
- Complex structure of electrophysiological gradients emerging during long-duration ventricular fibrillation in the canine heartAmerican Journal of Physiology-Heart and Circulatory Physiology, 2010
- Intramural Foci During Long Duration Fibrillation in the Pig VentricleCirculation Research, 2008
- Near-infrared voltage-sensitive fluorescent dyes optimized for optical mapping in blood-perfused myocardiumHeart Rhythm, 2007
- Optical measurements of intramural action potentials in isolated porcine hearts using optrodesHeart Rhythm, 2007
- New near-infrared optical probes of cardiac electrical activityAmerican Journal of Physiology-Heart and Circulatory Physiology, 2006
- Method for the three-dimensional localization of intramyocardial excitation centers using optical imagingJournal of Biomedical Optics, 2006
- Effect of plunge electrodes in active cardiac tissue with curving fibersHeart Rhythm, 2004
- Fiberglass needle electrodes for transmural cardiac mappingIEEE Transactions on Biomedical Engineering, 2002
- Evidence for a charge-shift electrochromic mechanism in a probe of membrane potentialNature, 1979
- Subendocardial origin of ventricular arrhythmias in 24-hour-old experimental myocardial infarction.Circulation, 1976