Bryan J. Caldwell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Bryan J. Caldwell has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Bruce H. Smaill
The University of Auckland
9 shared publications- Gregory B. Sands
Auckland Bioengineering Institute University of Auckland Auckland New Zealand
7 shared publications Ian J. LeGrice
The University of Auckland
6 shared publications- Mark L. Trew
Auckland Bioengineering Institute University of Auckland Auckland New Zealand
6 shared publications Darren A. Hooks
From the Auckland Bioengineering Institute (B.J.C., M.L.T., G.B.S., D.A.H., I.J.L., B.H.S.) and the Department of Physiology (I.J.L., B.H.S.), Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
4 shared publicationsAndrew J. Pullan
Department of Engineering Science
3 shared publications
Latest Publications
- 5 January 2022
- Published by Elsevier in Planetary and Space Science
- Vol. 212, 105409
Geological tasks during HI-SEAS planetary analog mission simulations, Mauna Loa, Hawai'i
- 5 January 2022
- Published by Elsevier in Planetary and Space Science
- Vol. 212, 105409
Geological tasks during HI-SEAS planetary analog mission simulations, Mauna Loa, Hawai'i
- 1 June 2015
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 8 (3) , 685-693
Cardiac Response to Low-Energy Field Pacing Challenges the Standard Theory of Defibrillation
Background—: The electric response of myocardial tissue to periodic field stimuli has attracted significant attention as the basis for low-energy antifibrillation pacing, potentially more effective than traditional single high-energy shocks. In conventional models, an electric field produces a highly nonuniform response of the myocardial wall, with discrete excitations, or hot spots (HS), occurring at cathodal tissue surfaces or large coronary vessels. We test this prediction using novel 3-dimensional tomographic optical imaging. Methods and Results—: Experiments were performed in isolated coronary perfused pig ventricular wall preparations stained with near-infrared voltage-sensitive fluorescent dye DI-4-ANBDQBS. The 3-dimensional coordinates of HS were determined using alternating transillumination. To relate HS formation with myocardial structures, we used ultradeep confocal imaging (interrogation depths, >4 mm). The peak HS distribution is located deep inside the heart wall, and the depth is not significantly affected by field polarity. We did not observe the strong colocalization of HS with major coronary vessels anticipated from theory. Yet, we observed considerable lateral displacement of HS with field polarity reversal. Models that de-emphasized lateral intracellular coupling and accounted for resistive heterogeneity in the extracellular space showed similar HS distributions to the experimental observations. Conclusions—: The HS distributions within the myocardial wall and the significant lateral displacements with field polarity reversal are inconsistent with standard theories of defibrillation. Extended theories based on enhanced descriptions of cellular scale electric mechanisms may be necessary. The considerable lateral displacement of HS with field polarity reversal supports the hypothesis of biphasic stimuli in low-energy antifibrillation pacing being advantageous.
- 1 June 2015
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 8 (3) , 685-693
Cardiac Response to Low-Energy Field Pacing Challenges the Standard Theory of Defibrillation
Background—: The electric response of myocardial tissue to periodic field stimuli has attracted significant attention as the basis for low-energy antifibrillation pacing, potentially more effective than traditional single high-energy shocks. In conventional models, an electric field produces a highly nonuniform response of the myocardial wall, with discrete excitations, or hot spots (HS), occurring at cathodal tissue surfaces or large coronary vessels. We test this prediction using novel 3-dimensional tomographic optical imaging. Methods and Results—: Experiments were performed in isolated coronary perfused pig ventricular wall preparations stained with near-infrared voltage-sensitive fluorescent dye DI-4-ANBDQBS. The 3-dimensional coordinates of HS were determined using alternating transillumination. To relate HS formation with myocardial structures, we used ultradeep confocal imaging (interrogation depths, >4 mm). The peak HS distribution is located deep inside the heart wall, and the depth is not significantly affected by field polarity. We did not observe the strong colocalization of HS with major coronary vessels anticipated from theory. Yet, we observed considerable lateral displacement of HS with field polarity reversal. Models that de-emphasized lateral intracellular coupling and accounted for resistive heterogeneity in the extracellular space showed similar HS distributions to the experimental observations. Conclusions—: The HS distributions within the myocardial wall and the significant lateral displacements with field polarity reversal are inconsistent with standard theories of defibrillation. Extended theories based on enhanced descriptions of cellular scale electric mechanisms may be necessary. The considerable lateral displacement of HS with field polarity reversal supports the hypothesis of biphasic stimuli in low-energy antifibrillation pacing being advantageous.
- Open Access
- 16 February 2011
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 2 (3) , 620-633
Imaging electrical excitation inside the myocardial wall
Cardiac arrhythmias are often triggered by ectopic membrane depolarization originating deep inside the myocardial wall. Here we propose a new method utilizing a novel near-infrared voltage-sensitive fluorescent dye DI-4-ANBDQBS to determine the three-dimensional (3D) coordinates of the sources of such depolarization. We tested the method in live preparations of pig left and right ventricular myocardium (thickness 8-18 mm) and phantoms imitating the optical properties of myocardial tissue. The method utilizes an alternating transillumination approach that involves comparing pairs of simultaneously recorded broad-field epifluorescence and transillumination images produced at two alternating directions of illumination. Recordings were taken simultaneously by two CCD cameras facing the endocardial and epicardial surfaces of the heart at a frame rate up to 3 KHz. In live preparations, we were able to localize the origin of the depolarization wave with a precision of ±1.3mm in the transmural direction and 3 mm in the image plane. The accuracy of detection was independent of the depth of the source inside ventricular wall.
- 16 February 2011
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 2 (3) , 620-633
Open AccessImaging electrical excitation inside the myocardial wall
Cardiac arrhythmias are often triggered by ectopic membrane depolarization originating deep inside the myocardial wall. Here we propose a new method utilizing a novel near-infrared voltage-sensitive fluorescent dye DI-4-ANBDQBS to determine the three-dimensional (3D) coordinates of the sources of such depolarization. We tested the method in live preparations of pig left and right ventricular myocardium (thickness 8-18 mm) and phantoms imitating the optical properties of myocardial tissue. The method utilizes an alternating transillumination approach that involves comparing pairs of simultaneously recorded broad-field epifluorescence and transillumination images produced at two alternating directions of illumination. Recordings were taken simultaneously by two CCD cameras facing the endocardial and epicardial surfaces of the heart at a frame rate up to 3 KHz. In live preparations, we were able to localize the origin of the depolarization wave with a precision of ±1.3mm in the transmural direction and 3 mm in the image plane. The accuracy of detection was independent of the depth of the source inside ventricular wall.
- 1 October 2010
- Published by Elsevier in Biophysical Journal
- Vol. 99 (7) , 2058-2066
Probing Field-Induced Tissue Polarization Using Transillumination Fluorescent Imaging
- 1 October 2010
- Published by Elsevier in Biophysical Journal
- Vol. 99 (7) , 2058-2066
Probing Field-Induced Tissue Polarization Using Transillumination Fluorescent Imaging
- 18 September 2010
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 39 (1) , 235-248
Three-Dimensional Cardiac Tissue Image Registration for Analysis of In Vivo Electrical Mapping
A method is presented for registering 3D cardiac tissue images to reference data, for the purpose of analyzing recorded electrical activity. Following left-ventricular in vivo electrical mapping studies in pig hearts, MRI is used to define a reference geometry in the tissue segment around the recording electrodes. The segment is then imaged in 3D using a high-resolution serial imaging microscopy technique. The tissue processing required for this introduces segment-wide distortion. Piecewise-smooth maps are used to correct the tissue distortion and register the 3D images with the reference MRI data. The methods are validated and techniques for identifying the preferred maps are proposed. Recorded electrical activation is shown to map reliably onto cardiac tissue structure using this registration method.
- 18 September 2010
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 39 (1) , 235-248
Three-Dimensional Cardiac Tissue Image Registration for Analysis of In Vivo Electrical Mapping
A method is presented for registering 3D cardiac tissue images to reference data, for the purpose of analyzing recorded electrical activity. Following left-ventricular in vivo electrical mapping studies in pig hearts, MRI is used to define a reference geometry in the tissue segment around the recording electrodes. The segment is then imaged in 3D using a high-resolution serial imaging microscopy technique. The tissue processing required for this introduces segment-wide distortion. Piecewise-smooth maps are used to correct the tissue distortion and register the 3D images with the reference MRI data. The methods are validated and techniques for identifying the preferred maps are proposed. Recorded electrical activation is shown to map reliably onto cardiac tissue structure using this registration method.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (1094687X) , 3948-3951
Shock induced electrical activation in structurally detailed models of pig left-ventricular tissue
Detailed models of sample specific structures in pig left-ventricular tissue have been constructed. These models include epicardial and endocardial surfaces, fiber and sheet orientations, vessels and cleavage planes with significant dimensions. This work shows that it is possible to extract from 3D tissue images reduced dimension descriptions of cleavage planes in the heart wall. These descriptions are used to analyze the response of tissue to electrical shocks of varying strengths. The presence of explicit discontinuities in the heart significantly reduces the time required for transmural activation and provides a basis for understanding successful defibrillation.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (1094687X) , 3948-3951
Shock induced electrical activation in structurally detailed models of pig left-ventricular tissue
Detailed models of sample specific structures in pig left-ventricular tissue have been constructed. These models include epicardial and endocardial surfaces, fiber and sheet orientations, vessels and cleavage planes with significant dimensions. This work shows that it is possible to extract from 3D tissue images reduced dimension descriptions of cleavage planes in the heart wall. These descriptions are used to analyze the response of tissue to electrical shocks of varying strengths. The presence of explicit discontinuities in the heart significantly reduces the time required for transmural activation and provides a basis for understanding successful defibrillation.
- 1 August 2009
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 2 (4) , 433-440
Three Distinct Directions of Intramural Activation Reveal Nonuniform Side-to-Side Electrical Coupling of Ventricular Myocytes
The anisotropy of cardiac tissue is a key determinant of 3D electric propagation and the stability of activation wave fronts in the heart. The electric properties of ventricular myocardium are widely assumed to be axially anisotropic, with activation propagating most rapidly in the myofiber direction and at uniform velocity transverse to this. We present new experimental evidence that contradicts this view. For the first time, high-density intramural electric mapping (325 electrodes at approximately 4x4x1-mm spacing) from pig left ventricular tissue was used to reconstruct 3D paced activation surfaces projected directly onto 3D tissue structure imaged throughout the same left ventricular volume. These data from 5 hearts demonstrate that ventricular tissue is electrically orthotropic with 3 distinct propagation directions that coincide with local microstructural axes defined by the laminar arrangement of ventricular myocytes. The maximum conduction velocity of 0.67+/-0.019 ms(-1) was aligned with the myofiber axis. However, transverse to this, the maximum conduction velocity was 0.30+/-0.010 ms(-1), parallel to the myocyte layers and 0.17+/-0.004 ms(-1) normal to them. These orthotropic conduction velocities give rise to preferential activation pathways across the left ventricular free wall that are not captured by structurally detailed computer models, which incorporate axially anisotropic electric properties. Our findings suggest that current views on uniform side-to-side electric coupling in the heart need to be revised. In particular, nonuniform laminar myocardial architecture and associated electric orthotropy should be included in future models of initiation and maintenance of ventricular arrhythmia.
- 1 August 2009
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 2 (4) , 433-440
Three Distinct Directions of Intramural Activation Reveal Nonuniform Side-to-Side Electrical Coupling of Ventricular Myocytes
The anisotropy of cardiac tissue is a key determinant of 3D electric propagation and the stability of activation wave fronts in the heart. The electric properties of ventricular myocardium are widely assumed to be axially anisotropic, with activation propagating most rapidly in the myofiber direction and at uniform velocity transverse to this. We present new experimental evidence that contradicts this view. For the first time, high-density intramural electric mapping (325 electrodes at approximately 4x4x1-mm spacing) from pig left ventricular tissue was used to reconstruct 3D paced activation surfaces projected directly onto 3D tissue structure imaged throughout the same left ventricular volume. These data from 5 hearts demonstrate that ventricular tissue is electrically orthotropic with 3 distinct propagation directions that coincide with local microstructural axes defined by the laminar arrangement of ventricular myocytes. The maximum conduction velocity of 0.67+/-0.019 ms(-1) was aligned with the myofiber axis. However, transverse to this, the maximum conduction velocity was 0.30+/-0.010 ms(-1), parallel to the myocyte layers and 0.17+/-0.004 ms(-1) normal to them. These orthotropic conduction velocities give rise to preferential activation pathways across the left ventricular free wall that are not captured by structurally detailed computer models, which incorporate axially anisotropic electric properties. Our findings suggest that current views on uniform side-to-side electric coupling in the heart need to be revised. In particular, nonuniform laminar myocardial architecture and associated electric orthotropy should be included in future models of initiation and maintenance of ventricular arrhythmia.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 137-140
Experiment-specific models of ventricular electrical activation: Construction and application
Experimental intramural recordings of electrical activity at high resolution have been made in the in-vivo pig LV free wall. To analyze features of these recordings experiment-specific 3D computer models of tissue structures and electrical behavior around the recording sites were constructed. The construction of the models used novel tissue image registration, correction and feature extraction methods. Appropriate model conductivity parameters were deduced from measurements and used to replicate features of experimental recordings.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 137-140
Experiment-specific models of ventricular electrical activation: Construction and application
Experimental intramural recordings of electrical activity at high resolution have been made in the in-vivo pig LV free wall. To analyze features of these recordings experiment-specific 3D computer models of tissue structures and electrical behavior around the recording sites were constructed. The construction of the models used novel tissue image registration, correction and feature extraction methods. Appropriate model conductivity parameters were deduced from measurements and used to replicate features of experimental recordings.
- 9 November 2007
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 101 (10) , e103-12
Laminar Arrangement of Ventricular Myocytes Influences Electrical Behavior of the Heart
The response of the heart to electrical shock, electrical propagation in sinus rhythm, and the spatiotemporal dynamics of ventricular fibrillation all depend critically on the electrical anisotropy of cardiac tissue. A long-held view of cardiac electrical anisotropy is that electrical conductivity is greatest along the myocyte axis allowing most rapid propagation of electrical activation in this direction, and that conductivity is isotropic transverse to the myocyte axis supporting a slower uniform spread of activation in this plane. In this context, knowledge of conductivity in two directions, parallel and transverse to the myofiber axis, is sufficient to characterize the electrical action of the heart. Here we present new experimental data that challenge this view. We have used a novel combination of intramural electrical mapping, and experiment-specific computer modeling, to demonstrate that left ventricular myocardium has unique bulk conductivities associated with three microstructurally-defined axes. We show that voltage fields induced by intramural current injection are influenced by not only myofiber direction, but also the transmural arrangement of muscle layers or myolaminae. Computer models of these experiments, in which measured 3D tissue structure was reconstructed in-silico, best matched recorded voltages with conductivities in the myofiber direction, and parallel and normal to myolaminae, set in the ratio 4:2:1, respectively. These findings redefine cardiac tissue as an electrically orthotropic substrate and enhance our understanding of how external shocks may act to successfully reset the fibrillating heart into a uniform electrical state. More generally, the mechanisms governing the destabilization of coordinated electrical propagation into ventricular arrhythmia need to be evaluated in the light of this discovery.
- 9 November 2007
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 101 (10) , e103-12
Laminar Arrangement of Ventricular Myocytes Influences Electrical Behavior of the Heart
The response of the heart to electrical shock, electrical propagation in sinus rhythm, and the spatiotemporal dynamics of ventricular fibrillation all depend critically on the electrical anisotropy of cardiac tissue. A long-held view of cardiac electrical anisotropy is that electrical conductivity is greatest along the myocyte axis allowing most rapid propagation of electrical activation in this direction, and that conductivity is isotropic transverse to the myocyte axis supporting a slower uniform spread of activation in this plane. In this context, knowledge of conductivity in two directions, parallel and transverse to the myofiber axis, is sufficient to characterize the electrical action of the heart. Here we present new experimental data that challenge this view. We have used a novel combination of intramural electrical mapping, and experiment-specific computer modeling, to demonstrate that left ventricular myocardium has unique bulk conductivities associated with three microstructurally-defined axes. We show that voltage fields induced by intramural current injection are influenced by not only myofiber direction, but also the transmural arrangement of muscle layers or myolaminae. Computer models of these experiments, in which measured 3D tissue structure was reconstructed in-silico, best matched recorded voltages with conductivities in the myofiber direction, and parallel and normal to myolaminae, set in the ratio 4:2:1, respectively. These findings redefine cardiac tissue as an electrically orthotropic substrate and enhance our understanding of how external shocks may act to successfully reset the fibrillating heart into a uniform electrical state. More generally, the mechanisms governing the destabilization of coordinated electrical propagation into ventricular arrhythmia need to be evaluated in the light of this discovery.
- 27 July 2007
- Published by Wiley in Microscopy Research and Technique
- Vol. 70 (10) , 886-894
Surface imaging microscopy using an ultramiller for large volume 3D reconstruction of wax‐ and resin‐embedded tissues
Three‐dimensional reconstruction of large tissue volumes using histological thin sections poses difficulties because of registration of sections, section distortion, and the possibility of incomplete data set collection due to section loss. We have constructed an integrated surface imaging system that successfully addresses these problems. Embedded tissue is mounted on a high precision XYZ stage and the upper surface is iteratively: (i) stained to provide an effective optical section, (ii) imaged using a digital camera, and (iii) removed with an ultramiller. This approach provides for the reconstruction of high‐quality 3D images by inherently preserving image registration, eliminates section distortion, thus removing the need for complex realignment and correction, and also ensures full capture of all image planes. The system has the capacity to acquire images of tissue structure with voxel sizes from 0.5 to 50 μm over dimensions ranging from micrometers to tens of millimeters. The ultramiller enables large samples to be imaged by reliably removing tissue over their full extent. The ability to visualize key features of 3D tissue structure across such a range of scale and resolution will facilitate the development of a greater understanding of the relationship between structure and function. This understanding is essential for better analyses of the structural changes associated with different disease states, and the development of structure‐based computer models of biological function. Microsc. Res. Tech., 2007.
- 27 July 2007
- Published by Wiley in Microscopy Research and Technique
- Vol. 70 (10) , 886-894
Surface imaging microscopy using an ultramiller for large volume 3D reconstruction of wax‐ and resin‐embedded tissues
Three‐dimensional reconstruction of large tissue volumes using histological thin sections poses difficulties because of registration of sections, section distortion, and the possibility of incomplete data set collection due to section loss. We have constructed an integrated surface imaging system that successfully addresses these problems. Embedded tissue is mounted on a high precision XYZ stage and the upper surface is iteratively: (i) stained to provide an effective optical section, (ii) imaged using a digital camera, and (iii) removed with an ultramiller. This approach provides for the reconstruction of high‐quality 3D images by inherently preserving image registration, eliminates section distortion, thus removing the need for complex realignment and correction, and also ensures full capture of all image planes. The system has the capacity to acquire images of tissue structure with voxel sizes from 0.5 to 50 μm over dimensions ranging from micrometers to tens of millimeters. The ultramiller enables large samples to be imaged by reliably removing tissue over their full extent. The ability to visualize key features of 3D tissue structure across such a range of scale and resolution will facilitate the development of a greater understanding of the relationship between structure and function. This understanding is essential for better analyses of the structural changes associated with different disease states, and the development of structure‐based computer models of biological function. Microsc. Res. Tech., 2007.