Abstract
As lithium-ion batteries (LIBs) are increasingly used in electric vehicles and grid-scale energy storage, thermal runaway (TR) remains a critical safety concern. TR releases intense heat, flammable vapors, toxic gases, and particulates, posing risks of fire, explosion, and environmental harm. Immersion cooling using dielectric battery thermal management fluids (BTMFs) has emerged as a promising mitigation strategy, yet its effects on TR and gas evolution remain unclear. In this study, 18650 cylindrical NCA cells were driven to TR either in air or fully submerged in non-aqueous BTMFs inside a 600 L environmental chamber equipped with heating, imaging, thermocouples, and in situ FTIR gas analysis. Results show that immersion substantially increases the energy required to initiate TR but does not alter intrinsic venting (115 °C–135 °C) or TR (170 °C–195 °C) temperature thresholds. Under immersion, only a brief (∼0.5 s) localized fire occurred and particulates largely remained in the fluid and later settled. Whereas air-cooled cells eject sustained burning electrolyte and generate widespread particulates. Headspace FTIR measurements indicate that immersion suppresses hydrocarbon release during venting, followed by a single burst upon TR. Overall, immersion cooling increases the TR energy barrier and mitigates hazardous emissions, though burst of volatiles upon runaway must be considered.
Funding Information
  • Lubrizol

This publication has 22 references indexed in Scilit: