Ya-Ting Tseng Liao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ya-Ting Tseng Liao has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Paul V. Ferkul
USRA, Cleveland, OH, USA
8 shared publications - Yanjun Li
Key Laboratory of Aircraft Environment Control and Life Support, MIIT, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
7 shared publications Wohan Cui
6 shared publicationsMichael C. Johnston
4 shared publications- Ankit Sharma
Technological Risk Research and Analysis Group (TRAG), Department of Mechanical and Industrial Engineering, Indian Institute of Technology Roorkee, Roorkee, India
3 shared publications Byoungchul Kwon
Department of Mechanical and Aerospace Engineering, Case Western Reserve University
3 shared publications
Latest Publications
- Open Access
- 21 August 2026
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 42
Numerical study of concurrent flow flame spread over thin solids in normoxic conditions in microgravity
- 21 August 2026
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 42
Open AccessNumerical study of concurrent flow flame spread over thin solids in normoxic conditions in microgravity
- Open Access
- 26 May 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (10) , 100512
Characterization and Off-Gassing Analysis of Lithium-Ion Battery Thermal Runaway Under Immersion Cooling
As lithium-ion batteries (LIBs) are increasingly used in electric vehicles and grid-scale energy storage, thermal runaway (TR) remains a critical safety concern. TR releases intense heat, flammable vapors, toxic gases, and particulates, posing risks of fire, explosion, and environmental harm. Immersion cooling using dielectric battery thermal management fluids (BTMFs) has emerged as a promising mitigation strategy, yet its effects on TR and gas evolution remain unclear. In this study, 18650 cylindrical NCA cells were driven to TR either in air or fully submerged in non-aqueous BTMFs inside a 600 L environmental chamber equipped with heating, imaging, thermocouples, and in situ FTIR gas analysis. Results show that immersion substantially increases the energy required to initiate TR but does not alter intrinsic venting (115 °C–135 °C) or TR (170 °C–195 °C) temperature thresholds. Under immersion, only a brief (∼0.5 s) localized fire occurred and particulates largely remained in the fluid and later settled. Whereas air-cooled cells eject sustained burning electrolyte and generate widespread particulates. Headspace FTIR measurements indicate that immersion suppresses hydrocarbon release during venting, followed by a single burst upon TR. Overall, immersion cooling increases the TR energy barrier and mitigates hazardous emissions, though burst of volatiles upon runaway must be considered.
- 26 May 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (10) , 100512
Open AccessCharacterization and Off-Gassing Analysis of Lithium-Ion Battery Thermal Runaway Under Immersion Cooling
As lithium-ion batteries (LIBs) are increasingly used in electric vehicles and grid-scale energy storage, thermal runaway (TR) remains a critical safety concern. TR releases intense heat, flammable vapors, toxic gases, and particulates, posing risks of fire, explosion, and environmental harm. Immersion cooling using dielectric battery thermal management fluids (BTMFs) has emerged as a promising mitigation strategy, yet its effects on TR and gas evolution remain unclear. In this study, 18650 cylindrical NCA cells were driven to TR either in air or fully submerged in non-aqueous BTMFs inside a 600 L environmental chamber equipped with heating, imaging, thermocouples, and in situ FTIR gas analysis. Results show that immersion substantially increases the energy required to initiate TR but does not alter intrinsic venting (115 °C–135 °C) or TR (170 °C–195 °C) temperature thresholds. Under immersion, only a brief (∼0.5 s) localized fire occurred and particulates largely remained in the fluid and later settled. Whereas air-cooled cells eject sustained burning electrolyte and generate widespread particulates. Headspace FTIR measurements indicate that immersion suppresses hydrocarbon release during venting, followed by a single burst upon TR. Overall, immersion cooling increases the TR energy barrier and mitigates hazardous emissions, though burst of volatiles upon runaway must be considered.
- Open Access
- 20 January 2026
- Published by Elsevier in Combustion and Flame
- Vol. 286
Computational fluid dynamics analysis of flame dynamics in partial gravity environments in a rotating centrifuge
- 20 January 2026
- Published by Elsevier in Combustion and Flame
- Vol. 286
Open AccessComputational fluid dynamics analysis of flame dynamics in partial gravity environments in a rotating centrifuge
- Open Access
- 9 October 2025
- Published by Elsevier in Applications in Energy and Combustion Science
- Vol. 24
Fire scale modeling and effects of buoyant flow on laminar upward flame spread
- 9 October 2025
- Published by Elsevier in Applications in Energy and Combustion Science
- Vol. 24
Open AccessFire scale modeling and effects of buoyant flow on laminar upward flame spread
- Open Access
- 1 April 2024
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 36 (2) , 1-13
Effects of Confinement on Opposed-Flow Flame Spread over Cellulose and Polymeric Solids in Microgravity
Opposed-flow flame spread over solid materials has been investigated in the past few decades owing to its importance in fundamental understanding of fires. These studies provided insights on the behavior of opposed-flow flames in different environmental conditions (e.g., flow speed, oxygen concentration). However, the effect of confinement on opposed-flow flames remains under-explored. It is known that confinement plays a critical role in concurrent-flow flame spread in normal and microgravity conditions. Hence, for a complete understanding it becomes important to understand the effects of confinement for opposed-flow flames. In this study, microgravity experiments are conducted aboard the International Space Station (ISS) to investigate opposed-flow flame spread in different confined conditions. Two materials, cotton-fiberglass blended textile fabric (SIBAL) and 1 mm thick polymethyl methacrylate (PMMA) slab are burned between a pair of parallel flow baffles in a small flow duct. By varying the sample-baffle distance, various levels of confinement are achieved (H = 1–2 cm). Three types of baffles, transparent, black, and reflective, are used to create different radiative boundary conditions. The purely forced flow speed is also varied (between 2.6 and 10.5 cm/s) to investigate its interplay with the confinement level. For both sample materials, it is observed that the flame spread rate decreases when the confinement level increases (i.e., when H decreases). In addition, flame spread rate is shown to have a positive correlation with flow speed, up to an optimal value. The results also indicate that the optimal flow speed for flame spread can decrease in highly confined conditions. Surface radiation on the confinement boundary is shown to play a key role. For SIBAL fabric, stronger flames are observed when using black baffles compared to transparent. For PMMA, reflective baffles yield stronger flames compared to black baffles. When comparing the results to the concurrent-flow case, it is also noticed that opposed-flow flames spread slower and blow off at larger flow speeds but are not as sensitive to the flow speed. This work provides unique long-duration microgravity experimental data that can inform the design of future opposed-flow experiments in microgravity and the development of theory and numerical models.
- 1 April 2024
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 36 (2) , 1-13
Open AccessEffects of Confinement on Opposed-Flow Flame Spread over Cellulose and Polymeric Solids in Microgravity
Opposed-flow flame spread over solid materials has been investigated in the past few decades owing to its importance in fundamental understanding of fires. These studies provided insights on the behavior of opposed-flow flames in different environmental conditions (e.g., flow speed, oxygen concentration). However, the effect of confinement on opposed-flow flames remains under-explored. It is known that confinement plays a critical role in concurrent-flow flame spread in normal and microgravity conditions. Hence, for a complete understanding it becomes important to understand the effects of confinement for opposed-flow flames. In this study, microgravity experiments are conducted aboard the International Space Station (ISS) to investigate opposed-flow flame spread in different confined conditions. Two materials, cotton-fiberglass blended textile fabric (SIBAL) and 1 mm thick polymethyl methacrylate (PMMA) slab are burned between a pair of parallel flow baffles in a small flow duct. By varying the sample-baffle distance, various levels of confinement are achieved (H = 1–2 cm). Three types of baffles, transparent, black, and reflective, are used to create different radiative boundary conditions. The purely forced flow speed is also varied (between 2.6 and 10.5 cm/s) to investigate its interplay with the confinement level. For both sample materials, it is observed that the flame spread rate decreases when the confinement level increases (i.e., when H decreases). In addition, flame spread rate is shown to have a positive correlation with flow speed, up to an optimal value. The results also indicate that the optimal flow speed for flame spread can decrease in highly confined conditions. Surface radiation on the confinement boundary is shown to play a key role. For SIBAL fabric, stronger flames are observed when using black baffles compared to transparent. For PMMA, reflective baffles yield stronger flames compared to black baffles. When comparing the results to the concurrent-flow case, it is also noticed that opposed-flow flames spread slower and blow off at larger flow speeds but are not as sensitive to the flow speed. This work provides unique long-duration microgravity experimental data that can inform the design of future opposed-flow experiments in microgravity and the development of theory and numerical models.
- Open Access
- 17 January 2024
- Published by Elsevier in Combustion and Flame
- Vol. 261
Numerical study of the effects of confinement on large-scale fires in microgravity
- 17 January 2024
- Published by Elsevier in Combustion and Flame
- Vol. 261
Open AccessNumerical study of the effects of confinement on large-scale fires in microgravity
- 31 March 2023
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 193,p. e65051
In Situ Gas Analysis and Fire Characterization of Lithium-Ion Cells During Thermal Runaway Using an Environmental Chamber
An experimental apparatus and a standard operating procedure (SOP) are developed to collect time-resolved data on the gas compositions and fire characteristics during and post-thermal runaway of lithium-ion battery (LIB) cells. A 18650 cylindrical cell is conditioned to a desired state-of-charge (SOC; 30%, 50%, 75%, and 100%) before each experiment. The conditioned cell is forced into a thermal runaway by an electrical heating tape at a constant heating rate (10 °C/min) in an environmental chamber (volume: ~600 L). The chamber is connected to a Fourier transform infrared (FTIR) gas analyzer for real-time concentration measurements. Two camcorders are used to record major events, such as cell venting, thermal runaway, and the subsequent burning process. The conditions of the cell, such as surface temperature, mass loss, and voltage, are also recorded. With the data obtained, cell pseudo-properties, venting gas compositions, and venting mass rate can be deduced as functions of cell temperature and cell SOC. While the test procedure is developed for a single cylindrical cell, it can be readily extended to test different cell formats and study fire propagation between multiple cells. The collected experimental data can also be used for the development of numerical models for LIB fires.
- 31 March 2023
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 193,p. e65051
In Situ Gas Analysis and Fire Characterization of Lithium-Ion Cells During Thermal Runaway Using an Environmental Chamber
An experimental apparatus and a standard operating procedure (SOP) are developed to collect time-resolved data on the gas compositions and fire characteristics during and post-thermal runaway of lithium-ion battery (LIB) cells. A 18650 cylindrical cell is conditioned to a desired state-of-charge (SOC; 30%, 50%, 75%, and 100%) before each experiment. The conditioned cell is forced into a thermal runaway by an electrical heating tape at a constant heating rate (10 °C/min) in an environmental chamber (volume: ~600 L). The chamber is connected to a Fourier transform infrared (FTIR) gas analyzer for real-time concentration measurements. Two camcorders are used to record major events, such as cell venting, thermal runaway, and the subsequent burning process. The conditions of the cell, such as surface temperature, mass loss, and voltage, are also recorded. With the data obtained, cell pseudo-properties, venting gas compositions, and venting mass rate can be deduced as functions of cell temperature and cell SOC. While the test procedure is developed for a single cylindrical cell, it can be readily extended to test different cell formats and study fire propagation between multiple cells. The collected experimental data can also be used for the development of numerical models for LIB fires.
- 10 February 2023
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 41 (1-2) , 32-50
Upward flame spread over discrete thin solids separated by heat-absorbing inert materials
Flame spread over discrete solid fuels has been of key research interest in the past few decades. Most studies considered an array of discrete fuels separated by air gaps or heat-insulating inert materials. The effects of heat loss due to the discrete configuration are not well understood. The present study aims to bridge this knowledge gap. A series of experiments are performed using a vertical array of thin discrete fuels separated by heat-absorbing inert materials of different thicknesses. For comparisons, experiments are also performed using discrete fuels separated by air gaps and using continuous fuel. The flame base spread rate is found to be generally higher in discrete fuel than in continuous fuel configurations, due to a reduced fuel load per unit length. It is also found that the air and inert gaps have opposite effects on the solid burning rates. The air gaps break the no-slip boundary, allowing the laterally entrained buoyancy flow (normal to the sample surface) to push the flame closer to the samples. This leads to an enhanced heat flux on the sample surface and an increased solid burning rate. On the other hand, the inert materials retain the flow boundary profile and act as a heat sink during flame spread, thereby reducing the solid burning rate. As the inert thickness increases, flame spread rate and solid burning rate decrease. Based on these observations, an existing model for flame spread rate is updated by incorporating the heat-absorbing effects of the gaps. The correlation is validated using the experimental data.
- 10 February 2023
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 41 (1-2) , 32-50
Upward flame spread over discrete thin solids separated by heat-absorbing inert materials
Flame spread over discrete solid fuels has been of key research interest in the past few decades. Most studies considered an array of discrete fuels separated by air gaps or heat-insulating inert materials. The effects of heat loss due to the discrete configuration are not well understood. The present study aims to bridge this knowledge gap. A series of experiments are performed using a vertical array of thin discrete fuels separated by heat-absorbing inert materials of different thicknesses. For comparisons, experiments are also performed using discrete fuels separated by air gaps and using continuous fuel. The flame base spread rate is found to be generally higher in discrete fuel than in continuous fuel configurations, due to a reduced fuel load per unit length. It is also found that the air and inert gaps have opposite effects on the solid burning rates. The air gaps break the no-slip boundary, allowing the laterally entrained buoyancy flow (normal to the sample surface) to push the flame closer to the samples. This leads to an enhanced heat flux on the sample surface and an increased solid burning rate. On the other hand, the inert materials retain the flow boundary profile and act as a heat sink during flame spread, thereby reducing the solid burning rate. As the inert thickness increases, flame spread rate and solid burning rate decrease. Based on these observations, an existing model for flame spread rate is updated by incorporating the heat-absorbing effects of the gaps. The correlation is validated using the experimental data.