The effect of femoral prosthesis design on patellofemoral contact stresses in total knee arthroplasty: a case–control study with mid-term follow-up minimum 3-year follow-up
Open Access
- 18 October 2023
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 18 (1) , 1-11
Abstract
Background: To investigate the differences in postoperative patellofemoral pressures and patellar tracking during at least three years of follow-up in patients using three prostheses of different designs in total knee arthroplasty (TKA) without patellar resurfacing. Methods: Radiographic investigations: The study included 401 patients who had a total of 480 knee prostheses implanted without patellar resurfacing. The prostheses used were Genesis II (external rotation design of femoral prosthesis), Triathlon (design with deep trochlear grooves), and Gemini MK II (deepening of trochlear groove and lateral condylar protrusion that closely follows the anatomical shape). The patients' patellar tracking was assessed by measuring patellar tilt and displacement during postoperative follow-up. Furthermore, postoperative knee function and pain were evaluated through range of motion, Knee Society scores (KSS), and Forgotten Joint Score (FJS) to compare the different groups. Finite element analysis: Constructing a finite element model of the knee joint of a normal volunteer after total knee arthroplasty using different prostheses for nonpatellar replacement. The three models' von Mises stress distribution heat map, peak contact pressure, and patellar transverse displacement were compared at 30°, 60°, and 90°, respectively. Results: Radiographic investigations: A total of 456 knees of 384 patients were investigated at a 3-year follow-up after TKA without patellar resurfacing. There were no significant differences in patellar tracking between the three groups. Patients with all three prostheses demonstrated favorable clinical outcomes at 3 years postoperatively, with no statistically significant differences in knee scores (91.9 vs 92.3 vs 91.8) or range of motion (127.9° vs 128.5° vs 127.7°) between the groups. However, there was a significant difference between Genesis II and Gemini MK II in the Forgotten Joint Score (59.7 vs 62.4). Patients with persistent postoperative anterior knee pain were present in all three groups (16 vs 12 vs 10), but the incidence was not significantly different. Finite element analysis: The von Mises stress distribution heat map showed that during flexion, the patellofemoral stresses were mainly concentrated on the lateral side of the prosthesis side, and the contact site gradually shifted downward with increasing flexion angle. At the same time, the peak contact stress of the patellofemoral joint increased with the gradual increase in the flexion angle. Genesis II, with a wider and shallower trochlear groove, showed greater patellofemoral stresses and lateral patellar displacement after TKA without patellar resurfacing. The Gemini MK II with a deeper trochlear groove and slightly protruding lateral condyle is more in line with anatomical design, with smaller patellofemoral joint pressure and better patellar tracking. Conclusions: In TKA without patellar resurfacing, a prosthesis with a deeper trochlear groove, a slightly higher lateral femoral condyle, and a more anatomically designed knee that better matches the patellar morphology should be a better choice.Keywords
This publication has 32 references indexed in Scilit:
- Patellar Resurfacing in Total Knee Arthroplasty: Does Design Matter?Journal of Bone and Joint Surgery, 2011
- Computationally Efficient Finite Element Evaluation of Natural Patellofemoral MechanicsJournal of Biomechanical Engineering, 2010
- Patella in total knee arthroplasty: to resurface or not to—a cohort study of staged bilateral total knee arthroplastyInternational Orthopaedics, 2010
- The effect of the design of the femoral component on the conformity of the patellofemoral joint in total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2007
- Patellar Resurfacing in Total Knee ArthroplastyA Meta-AnalysisJournal of Bone and Joint Surgery, 2005
- Effect of Femoral Component Design on Unresurfaced Patellas in Knee ArthroplastyClinical Orthopaedics and Related Research, 2003
- Patellofemoral ImagingClinical Orthopaedics and Related Research, 2001
- Kinematic total knee arthroplastyThe Journal of Arthroplasty, 1999
- Patellar Prosthesis Positioning in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1988
- Patellar Pain and IncongruenceClinical Orthopaedics and Related Research, 1983