Early and Midterm Outcomes of Transcatheter Aortic-Valve Replacement with Balloon-Expandable Versus Self-Expanding Valves: A Systematic Review and Meta-Analysis
Preprint
Abstract
Background: The comparative performances of transcatheter aortic-valve replacement (TAVR) with balloon-expandable valves (BEV) and self-expanding valves (SEV) in severe aortic stenosis remain unclear. Purpose: To compare the early (30-day) and midterm (1-year) mortality and cardiovascular outcomes of BEV with SEV. Data Sources: PubMed, EMBASE, and the Cochrane Library from inception until February 13, 2020. Study Selection: 3 randomized controlled trials (RCTs) and 12 propensity-score matched (PSM) studies, with 37,958 patients. Data Extraction: 2 reviewers independently extracted study data and rated study quality. Data Synthesis: Compared with SEV, BEV was associated with significantly lower mortality at 30 days (OR 0.77, 95% CI 0.71–0.83, P< 0.00001, I 2 =0) and a trend toward lower mortality at 1 year (OR 0.88, 95% CI 0.78–1.00, P= 0.05, I 2 =15.8%), mainly driven from PSM studies, but regardless of valve generations and SEV types. 30-day and 1-year cardiovascular mortality, 30-day incidences of moderate to severe paravavular leak, procedural contrast agent volume and procedure time were lower, but transvalvular pressure gradient was higher in BEV than SEV. 30-day incidences of permanent pacemaker implantation (PPI), acute kidney injury, stroke, major bleeding, major vascular complications and rehospitalization were not statistically different between BEV and SEV. Early-generation SEV was associated with a higher 30-day PPI risk than corresponding BEV comparators. PPI risk was lower in ACURATE neo but higher in Evolut R SEV, both compared with SAPIEN 3 BEV. Limitations: Study-level but not patient-level data; residual confounders in PSM studies; study designs and patient characteristics were heterogeneous. Conclusions: Compared with SEV, BEV might be associated with lower early and midterm mortality. Results from adequately powered RCTs with long-term follow-up are critically needed to confirm these findings. Registration: PROSPERO (CRD42020172889). Funding Source: National Natural Science Foundation of China (NO. 81600312).Keywords
All Related Versions
- Published version: Journal of Cardiology, 80 (3), 204.
This publication has 32 references indexed in Scilit:
- Propensity‐matched comparison between Direct Flow Medical, Medtronic Corevalve, and Edwards Sapien XT prostheses: Device success, thirty‐day safety, and mortalityCatheterization and Cardiovascular Interventions, 2015
- Comparison of Balloon-Expandable vs Self-expandable Valves in Patients Undergoing Transcatheter Aortic Valve ReplacementJAMA, 2014
- The Hartung-Knapp-Sidik-Jonkman method for random effects meta-analysis is straightforward and considerably outperforms the standard DerSimonian-Laird methodBMC Medical Research Methodology, 2014
- Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve ReplacementJACC, 2013
- Transcatheter Aortic Valve Implantation With the Edwards SAPIEN Versus the Medtronic CoreValve Revalving System DevicesJACC, 2013
- An Introduction to Propensity Score Methods for Reducing the Effects of Confounding in Observational StudiesMultivariate Behavioral Research, 2011
- Systematic differences in treatment effect estimates between propensity score methods and logistic regressionInternational Journal of Epidemiology, 2008
- A critical appraisal of propensity‐score matching in the medical literature between 1996 and 2003Statistics in Medicine, 2007
- Comparison of Logistic Regression versus Propensity Score When the Number of Events Is Low and There Are Multiple ConfoundersAmerican Journal of Epidemiology, 2003
- Estimating Causal Effects from Large Data Sets Using Propensity ScoresAnnals of Internal Medicine, 1997