Rong Fang Lan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rong Fang Lan has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Wei Xu
Department of Cardiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
2 shared publications - Xinlin Zhang
Department of Cardiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
2 shared publications Biao Xu
1 shared publication- Biao Xu
Department of Cardiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, No. 321 Zhongshan Road, Nanjing 210008, China
1 shared publication - Hongsong Yu
Department of Cardiology, Nanjing University Medical School Affiliated Nanjing Drum Tower Hospital, Zhongshan Road No.321, Nanjing, 210000, China
1 shared publication - Jianzhou Chen
Department of Cardiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China
1 shared publication
Latest Publications
- Open Access
Early and Midterm Outcomes of Transcatheter Aortic-Valve Replacement with Balloon-Expandable Versus Self-Expanding Valves: A Systematic Review and Meta-Analysis
Background: The comparative performances of transcatheter aortic-valve replacement (TAVR) with balloon-expandable valves (BEV) and self-expanding valves (SEV) in severe aortic stenosis remain unclear. Purpose: To compare the early (30-day) and midterm (1-year) mortality and cardiovascular outcomes of BEV with SEV. Data Sources: PubMed, EMBASE, and the Cochrane Library from inception until February 13, 2020. Study Selection: 3 randomized controlled trials (RCTs) and 12 propensity-score matched (PSM) studies, with 37,958 patients. Data Extraction: 2 reviewers independently extracted study data and rated study quality. Data Synthesis: Compared with SEV, BEV was associated with significantly lower mortality at 30 days (OR 0.77, 95% CI 0.71–0.83, P< 0.00001, I 2 =0) and a trend toward lower mortality at 1 year (OR 0.88, 95% CI 0.78–1.00, P= 0.05, I 2 =15.8%), mainly driven from PSM studies, but regardless of valve generations and SEV types. 30-day and 1-year cardiovascular mortality, 30-day incidences of moderate to severe paravavular leak, procedural contrast agent volume and procedure time were lower, but transvalvular pressure gradient was higher in BEV than SEV. 30-day incidences of permanent pacemaker implantation (PPI), acute kidney injury, stroke, major bleeding, major vascular complications and rehospitalization were not statistically different between BEV and SEV. Early-generation SEV was associated with a higher 30-day PPI risk than corresponding BEV comparators. PPI risk was lower in ACURATE neo but higher in Evolut R SEV, both compared with SAPIEN 3 BEV. Limitations: Study-level but not patient-level data; residual confounders in PSM studies; study designs and patient characteristics were heterogeneous. Conclusions: Compared with SEV, BEV might be associated with lower early and midterm mortality. Results from adequately powered RCTs with long-term follow-up are critically needed to confirm these findings. Registration: PROSPERO (CRD42020172889). Funding Source: National Natural Science Foundation of China (NO. 81600312).
Open AccessEarly and Midterm Outcomes of Transcatheter Aortic-Valve Replacement with Balloon-Expandable Versus Self-Expanding Valves: A Systematic Review and Meta-Analysis
Background: The comparative performances of transcatheter aortic-valve replacement (TAVR) with balloon-expandable valves (BEV) and self-expanding valves (SEV) in severe aortic stenosis remain unclear. Purpose: To compare the early (30-day) and midterm (1-year) mortality and cardiovascular outcomes of BEV with SEV. Data Sources: PubMed, EMBASE, and the Cochrane Library from inception until February 13, 2020. Study Selection: 3 randomized controlled trials (RCTs) and 12 propensity-score matched (PSM) studies, with 37,958 patients. Data Extraction: 2 reviewers independently extracted study data and rated study quality. Data Synthesis: Compared with SEV, BEV was associated with significantly lower mortality at 30 days (OR 0.77, 95% CI 0.71–0.83, P< 0.00001, I 2 =0) and a trend toward lower mortality at 1 year (OR 0.88, 95% CI 0.78–1.00, P= 0.05, I 2 =15.8%), mainly driven from PSM studies, but regardless of valve generations and SEV types. 30-day and 1-year cardiovascular mortality, 30-day incidences of moderate to severe paravavular leak, procedural contrast agent volume and procedure time were lower, but transvalvular pressure gradient was higher in BEV than SEV. 30-day incidences of permanent pacemaker implantation (PPI), acute kidney injury, stroke, major bleeding, major vascular complications and rehospitalization were not statistically different between BEV and SEV. Early-generation SEV was associated with a higher 30-day PPI risk than corresponding BEV comparators. PPI risk was lower in ACURATE neo but higher in Evolut R SEV, both compared with SAPIEN 3 BEV. Limitations: Study-level but not patient-level data; residual confounders in PSM studies; study designs and patient characteristics were heterogeneous. Conclusions: Compared with SEV, BEV might be associated with lower early and midterm mortality. Results from adequately powered RCTs with long-term follow-up are critically needed to confirm these findings. Registration: PROSPERO (CRD42020172889). Funding Source: National Natural Science Foundation of China (NO. 81600312).
- Open Access
- 10 June 2019
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 19 (1) , 1-10
Residual flow may increase the risk of adverse events in patients received combined catheter ablation and transcatheter left atrial appendage closure for nonvalvular atrial fibrillation: a meta-analysis
Catheter ablation (CA) and left atrial appendage closure (LAAC) have been combined into a novel one-stop procedure for patients with atrial fibrillation (AF). However, postoperative complications are relatively common in patients undergoing LAAC; the complications, including residual flow, increase in the risk of bleeding, or other adverse events, are unknown in patients receiving one-stop therapy. Therefore, we tried to evaluate the adverse events of CA and LAAC hybrid therapy in patients with nonvalvular AF. We performed a meta-analysis and computer-based literature search to identify publications listed in the PubMed, Embase, and Cochrane library databases. Studies were included if patients received CA and LAAC hybrid therapy and reported adverse events. Overall 13 studies involving 952 patients were eligible based on the inclusion criteria. In the periprocedural period, the pooled incidence of pericardial effusion was 3.15%. The rates of bleeding events and residual flow were 5.02 and 9.11%, respectively. During follow-up, the rates of all-cause mortality, embolism events, bleeding events, AF recurrence, and residual flow were 2.15, 5.24, 6.95, 32.89, and 15.35%, respectively. The maximum occurrence probability of residual flow events was 21.87%. Bleeding events were more common in patients with a higher procedural residual flow event rate (P = 0.03). A higher AF recurrence rate indicated higher rates of embolism events (P = 0.04) and residual flow (P = 0.03) during follow-up. Bleeding events were more common in patients with a higher procedural residual flow event rate. However, combined CA and LAAC therapy is reasonably safe and efficacious in patients with nonvalvular AF. Further studies on the safety and efficacy of CA or LAAC alone are necessary in future.
- 10 June 2019
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 19 (1) , 1-10
Open AccessResidual flow may increase the risk of adverse events in patients received combined catheter ablation and transcatheter left atrial appendage closure for nonvalvular atrial fibrillation: a meta-analysis
Catheter ablation (CA) and left atrial appendage closure (LAAC) have been combined into a novel one-stop procedure for patients with atrial fibrillation (AF). However, postoperative complications are relatively common in patients undergoing LAAC; the complications, including residual flow, increase in the risk of bleeding, or other adverse events, are unknown in patients receiving one-stop therapy. Therefore, we tried to evaluate the adverse events of CA and LAAC hybrid therapy in patients with nonvalvular AF. We performed a meta-analysis and computer-based literature search to identify publications listed in the PubMed, Embase, and Cochrane library databases. Studies were included if patients received CA and LAAC hybrid therapy and reported adverse events. Overall 13 studies involving 952 patients were eligible based on the inclusion criteria. In the periprocedural period, the pooled incidence of pericardial effusion was 3.15%. The rates of bleeding events and residual flow were 5.02 and 9.11%, respectively. During follow-up, the rates of all-cause mortality, embolism events, bleeding events, AF recurrence, and residual flow were 2.15, 5.24, 6.95, 32.89, and 15.35%, respectively. The maximum occurrence probability of residual flow events was 21.87%. Bleeding events were more common in patients with a higher procedural residual flow event rate (P = 0.03). A higher AF recurrence rate indicated higher rates of embolism events (P = 0.04) and residual flow (P = 0.03) during follow-up. Bleeding events were more common in patients with a higher procedural residual flow event rate. However, combined CA and LAAC therapy is reasonably safe and efficacious in patients with nonvalvular AF. Further studies on the safety and efficacy of CA or LAAC alone are necessary in future.