Analysis of Small Area Metal Surfaces Using Infrared External Reflection Spectroscopy
- 26 August 2025
- journal article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 79 (9) , 1429-1440
Abstract
This paper reports on the application of infrared external reflection spectroscopy (IR-ERS) to the characterization of small surface area addresses prepared on smooth gold surfaces after modification for use as capture substrates in sandwich immunoassays based on surface-enhanced Raman scattering (SERS). Most of the past work with IR-ERS on analyzing coatings formed on highly reflective metals utilized relatively large area samples (e.g., 76 × 25 mm glass microscope slides and ∼51 mm diameter silicon wafers) to accommodate the large size of the elliptical IR beam reflected off the metal surface at grazing angles of incidence. Our interest in employing assay-sized (3 mm diameter) addresses for IR-ERS measurements arises from the need to minimize the consumption, and, thereby, the expense of rare biological reagents like the antibodies under development for immunoassays to detect tuberculosis. The obvious approach to achieving this goal would be to utilize the spatial resolution and sample scanning capabilities of Fourier transform infrared (FT-IR) microscopes. We, however, opted to re-examine the physical optics and geometric layout of the measurement through an analysis of the strength of the mean square electric field at the sample/substrate interface as a function of angle of incidence. These findings suggested that, given the high light throughput and low noise levels of today’s FT-IR spectrometers, it may be possible to perform these measurements simply by collecting spectra at a lower angle of incidence when using the optical layout of a standard IR-ERS experiment. Herein, we report both the theoretical analysis and experimental results that demonstrate it is possible to obtain useful spectra from much smaller samples than those traditionally used, e.g., those employed in our SERS-based immunoassays, simply by decreasing the angle at which the IR beam is incident on the sample surface. We also demonstrate that these types of samples can be analyzed by constructing a small jig that allows for the careful positioning of the sample in the IR beam, rather than by extensively modifying the optics of the IR-ERS accessory.Keywords
Funding Information
- Kerith Foundation
- Immunology, Inflammation, and Infections Disease (3i) Initiative, University of Utah
- National Institute of Environmental Health Sciences (75N93019C00023)
This publication has 47 references indexed in Scilit:
- Reflection Absorption IR Spectroscopy (RAIRS)2011
- Electrochemical and infrared spectroscopy studies of 4-mercaptobenzoic acid SAMs on gold surfacesElectrochimica Acta, 2008
- Infrared spectroscopy of proteinsBiochimica et Biophysica Acta (BBA) - Bioenergetics, 2007
- Infrared Spectroscopy of Proteins2001
- Comments on the Optical Constants of Metals and an Introduction to the Data for Several Metals1997
- Covalent immobilization of native biomolecules onto Au(111) via N-hydroxysuccinimide ester functionalized self-assembled monolayers for scanning probe microscopyBiophysical Journal, 1996
- Formation and structure of a spontaneously adsorbed monolayer of arachidic on silverChemical Physics Letters, 1986
- Plenary Lecture: Transmission and Reflection Spectroscopy, Nature of the Spectra1977
- Possible importance of a “metal-surface selection rule” in the interpretation of the infrared spectra of molecules adsorbed on particulate metals; infrared spectra from ethylene chemisorbed on silica-supported metal catalystsSurface Science, 1976
- Differential reflection spectroscopy of very thin surface filmsSurface Science, 1971