Eamonn Clarke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eamonn Clarke has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Marc D. Porter
Department of Chemistry, University of Utah, Salt Lake City, Utah 84112, USA
5 shared publications - Lars B. Laurentius
Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112, USA
2 shared publications Adam Johan Bergren
Nanotechnology Research Centre National Research Council of Canada Edmonton AB T6G 2M9 Canada Department of Chemistry University of British Columbia Kelowna BC V1V 1V7 Canada
1 shared publication- Bruce K. Gale
Department of Mechanical Engineering, University of Utah, Salt Lake City, UT 84112, USA
1 shared publication - Carol Korzeniewski
Department of Chemistry and Biochemistry Texas Tech University Lubbock Texas USA
1 shared publication Christie A. McDermott
Department of Chemistry University of Alberta Edmonton Alberta T6G 2G2
1 shared publication
Latest Publications
- 26 August 2025
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 79 (9) , 1429-1440
Analysis of Small Area Metal Surfaces Using Infrared External Reflection Spectroscopy
This paper reports on the application of infrared external reflection spectroscopy (IR-ERS) to the characterization of small surface area addresses prepared on smooth gold surfaces after modification for use as capture substrates in sandwich immunoassays based on surface-enhanced Raman scattering (SERS). Most of the past work with IR-ERS on analyzing coatings formed on highly reflective metals utilized relatively large area samples (e.g., 76 × 25 mm glass microscope slides and ∼51 mm diameter silicon wafers) to accommodate the large size of the elliptical IR beam reflected off the metal surface at grazing angles of incidence. Our interest in employing assay-sized (3 mm diameter) addresses for IR-ERS measurements arises from the need to minimize the consumption, and, thereby, the expense of rare biological reagents like the antibodies under development for immunoassays to detect tuberculosis. The obvious approach to achieving this goal would be to utilize the spatial resolution and sample scanning capabilities of Fourier transform infrared (FT-IR) microscopes. We, however, opted to re-examine the physical optics and geometric layout of the measurement through an analysis of the strength of the mean square electric field at the sample/substrate interface as a function of angle of incidence. These findings suggested that, given the high light throughput and low noise levels of today’s FT-IR spectrometers, it may be possible to perform these measurements simply by collecting spectra at a lower angle of incidence when using the optical layout of a standard IR-ERS experiment. Herein, we report both the theoretical analysis and experimental results that demonstrate it is possible to obtain useful spectra from much smaller samples than those traditionally used, e.g., those employed in our SERS-based immunoassays, simply by decreasing the angle at which the IR beam is incident on the sample surface. We also demonstrate that these types of samples can be analyzed by constructing a small jig that allows for the careful positioning of the sample in the IR beam, rather than by extensively modifying the optics of the IR-ERS accessory.
- 26 August 2025
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 79 (9) , 1429-1440
Analysis of Small Area Metal Surfaces Using Infrared External Reflection Spectroscopy
This paper reports on the application of infrared external reflection spectroscopy (IR-ERS) to the characterization of small surface area addresses prepared on smooth gold surfaces after modification for use as capture substrates in sandwich immunoassays based on surface-enhanced Raman scattering (SERS). Most of the past work with IR-ERS on analyzing coatings formed on highly reflective metals utilized relatively large area samples (e.g., 76 × 25 mm glass microscope slides and ∼51 mm diameter silicon wafers) to accommodate the large size of the elliptical IR beam reflected off the metal surface at grazing angles of incidence. Our interest in employing assay-sized (3 mm diameter) addresses for IR-ERS measurements arises from the need to minimize the consumption, and, thereby, the expense of rare biological reagents like the antibodies under development for immunoassays to detect tuberculosis. The obvious approach to achieving this goal would be to utilize the spatial resolution and sample scanning capabilities of Fourier transform infrared (FT-IR) microscopes. We, however, opted to re-examine the physical optics and geometric layout of the measurement through an analysis of the strength of the mean square electric field at the sample/substrate interface as a function of angle of incidence. These findings suggested that, given the high light throughput and low noise levels of today’s FT-IR spectrometers, it may be possible to perform these measurements simply by collecting spectra at a lower angle of incidence when using the optical layout of a standard IR-ERS experiment. Herein, we report both the theoretical analysis and experimental results that demonstrate it is possible to obtain useful spectra from much smaller samples than those traditionally used, e.g., those employed in our SERS-based immunoassays, simply by decreasing the angle at which the IR beam is incident on the sample surface. We also demonstrate that these types of samples can be analyzed by constructing a small jig that allows for the careful positioning of the sample in the IR beam, rather than by extensively modifying the optics of the IR-ERS accessory.
- 23 January 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (8) , 1930-1935
Homebuilt cost-effective nitrogen blowdown evaporator
A nitrogen blowdown evaporator built with widely-available materials and techniques is described, accompanied by plans and detailed instructions for assembly. We show that the apparatus operates without causing contamination or sample loss.
- 23 January 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (8) , 1930-1935
Homebuilt cost-effective nitrogen blowdown evaporator
A nitrogen blowdown evaporator built with widely-available materials and techniques is described, accompanied by plans and detailed instructions for assembly. We show that the apparatus operates without causing contamination or sample loss.
- 17 July 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (31) , 5475-5481
Microfluidic platform for the enzymatic pretreatment of human serum for the detection of the tuberculosis biomarker mannose-capped lipoarabinomannan
Tuberculosis (TB) represents a major public health threat, with millions of new cases reported worldwide each year. A major hurdle to curtailing the spread of this disease is the need for low-cost, point-of-care (PoC) diagnostics. Mannose-capped lipoarabinomannan, a significant component of the Mycobacterium tuberculosis bacillus, has been heavily studied as a biomarker for TB, but with little success due to its complexation with endogenous components of body fluids in a manner that sterically interferes with its detection by ELISA and other immunoassays. Recent work by our group and others has shown that complexation can be disrupted with protein-denaturing protocols. By way of followup, we recently described an enzymatic digestion (Proteinase K) sample pretreatment that enables quantitative recovery of ManLAM spiked into healthy human control serum. Herein, we report on the transfer of our benchtop sample pretreatment methodology to an automated microfluidic platform. We show that this platform can be configured to: (1) carry out the pretreatment process with very little user interaction and, (2) yield recoveries for ManLAm spiked into control serum which are statistically indistinguishable from those achieved by the benchtop process. Plans to integrate this device with a portable sample reader as a possible basis for a PoC TB diagnostic system and analyze patient samples are briefly discussed.
- 17 July 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (31) , 5475-5481
Microfluidic platform for the enzymatic pretreatment of human serum for the detection of the tuberculosis biomarker mannose-capped lipoarabinomannan
Tuberculosis (TB) represents a major public health threat, with millions of new cases reported worldwide each year. A major hurdle to curtailing the spread of this disease is the need for low-cost, point-of-care (PoC) diagnostics. Mannose-capped lipoarabinomannan, a significant component of the Mycobacterium tuberculosis bacillus, has been heavily studied as a biomarker for TB, but with little success due to its complexation with endogenous components of body fluids in a manner that sterically interferes with its detection by ELISA and other immunoassays. Recent work by our group and others has shown that complexation can be disrupted with protein-denaturing protocols. By way of followup, we recently described an enzymatic digestion (Proteinase K) sample pretreatment that enables quantitative recovery of ManLAM spiked into healthy human control serum. Herein, we report on the transfer of our benchtop sample pretreatment methodology to an automated microfluidic platform. We show that this platform can be configured to: (1) carry out the pretreatment process with very little user interaction and, (2) yield recoveries for ManLAm spiked into control serum which are statistically indistinguishable from those achieved by the benchtop process. Plans to integrate this device with a portable sample reader as a possible basis for a PoC TB diagnostic system and analyze patient samples are briefly discussed.
- 5 June 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (24) , 9191-9198
Proteinase K Pretreatment for the Quantitative Recovery and Sensitive Detection of the Tuberculosis Biomarker Mannose-Capped Lipoarabinomannan Spiked into Human Serum
This paper reports on an investigation of an enzymatic pretreatment protocol using proteinase K (ProK) for the analysis of human serum samples spiked with mannose-capped lipoarabinomannan (ManLAM). ManLAM is an antigenic biomarker found in the serum, urine, and other body fluids of individuals infected with tuberculosis (TB). Immunometric measurements of ManLAM are compromised by steric effects due to its complexation with high-molecular-weight components in these matrices that interfere with its capture and/or labeling. Recent work has shown that deproteinization of these types of samples by perchloric acid acidification or ProK digestion releases ManLAM from complexation. Releasing ManLAM greatly improves its detectability and, as a result, its utility as a TB biomarker. The work detailed herein examined how different ProK reaction conditions (e.g., enzyme concentration and digestion time and temperature) affect the recovery and detectability of ManLAM in human serum. As measured by enzyme-linked immunosorbent assay (ELISA), we show that using the optimal set of digestion conditions to free ManLAM, which also yield a small, quantitatively reproducible level of sample concentration, it is possible to achieve a spiked ManLAM recovery of 98 ± 13% and a limit of detection of 10 pg/mL (0.6 pM). Experiments also demonstrated that the ELISA responses measured for a given ManLAM concentration in serum after pretreatment were statistically indistinguishable from those directly determined for the same amounts of ManLAM added to an innocuous buffered solution. Possible adaptations of the digestion protocol for use in point-of-care TB testing are also briefly discussed.
- 5 June 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (24) , 9191-9198
Proteinase K Pretreatment for the Quantitative Recovery and Sensitive Detection of the Tuberculosis Biomarker Mannose-Capped Lipoarabinomannan Spiked into Human Serum
This paper reports on an investigation of an enzymatic pretreatment protocol using proteinase K (ProK) for the analysis of human serum samples spiked with mannose-capped lipoarabinomannan (ManLAM). ManLAM is an antigenic biomarker found in the serum, urine, and other body fluids of individuals infected with tuberculosis (TB). Immunometric measurements of ManLAM are compromised by steric effects due to its complexation with high-molecular-weight components in these matrices that interfere with its capture and/or labeling. Recent work has shown that deproteinization of these types of samples by perchloric acid acidification or ProK digestion releases ManLAM from complexation. Releasing ManLAM greatly improves its detectability and, as a result, its utility as a TB biomarker. The work detailed herein examined how different ProK reaction conditions (e.g., enzyme concentration and digestion time and temperature) affect the recovery and detectability of ManLAM in human serum. As measured by enzyme-linked immunosorbent assay (ELISA), we show that using the optimal set of digestion conditions to free ManLAM, which also yield a small, quantitatively reproducible level of sample concentration, it is possible to achieve a spiked ManLAM recovery of 98 ± 13% and a limit of detection of 10 pg/mL (0.6 pM). Experiments also demonstrated that the ELISA responses measured for a given ManLAM concentration in serum after pretreatment were statistically indistinguishable from those directly determined for the same amounts of ManLAM added to an innocuous buffered solution. Possible adaptations of the digestion protocol for use in point-of-care TB testing are also briefly discussed.
- 6 April 2022
- Published by Wiley in Electroanalysis
- Vol. 34 (12) , 1936-1952
On the Counter‐intuitive Heterogeneous Electron Transfer Barrier Properties of Alkanethiolate Monolayers on Gold: Smooth versus Rough Surfaces
Alkanethiolate monolayers formed on rough gold surfaces can, somewhat surprisingly, act as stronger barriers to heterogeneous electron transfer than those on smooth gold surfaces. This paper presents a possible explanation for this observation by constructing simple geometric models of a “rough” and “smooth” gold surface to examine how microscopic roughness differences can affect the nucleation/growth of the adlayer and size/density of structural defects. Expectedly, the number of defects predicted for adlayers formed on smooth gold is lower than any of those for rough gold. The counter‐intuitive result is that the sizes of a small portion of the defects in the adlayer on the smooth surface are larger than any of those found on the rough surface. The potential implications of these results are discussed.
- 6 April 2022
- Published by Wiley in Electroanalysis
- Vol. 34 (12) , 1936-1952
On the Counter‐intuitive Heterogeneous Electron Transfer Barrier Properties of Alkanethiolate Monolayers on Gold: Smooth versus Rough Surfaces
Alkanethiolate monolayers formed on rough gold surfaces can, somewhat surprisingly, act as stronger barriers to heterogeneous electron transfer than those on smooth gold surfaces. This paper presents a possible explanation for this observation by constructing simple geometric models of a “rough” and “smooth” gold surface to examine how microscopic roughness differences can affect the nucleation/growth of the adlayer and size/density of structural defects. Expectedly, the number of defects predicted for adlayers formed on smooth gold is lower than any of those for rough gold. The counter‐intuitive result is that the sizes of a small portion of the defects in the adlayer on the smooth surface are larger than any of those found on the rough surface. The potential implications of these results are discussed.