Influence of outlet orientation and variable tube length on high temperature zones of U‐tube trisection helical baffle electric heaters
Authors:
- 19 November 2019
- journal article
- research article
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 98 (4) , 1017-1030
Abstract
Numerical simulation was performed to optimize temperature distribution especially at high temperature zones at the rear part of U‐tube bundle electric heaters with unique one‐plus‐two U‐tube layouts. The influences of variable tube lengths and different outlet nozzle orientations on flow and thermal features on axial separation trisection helical baffle schemes in contrast to segmental schemes were investigated. The results show that the variable tube length schemes can effectively ameliorate high temperature zones and obtain more uniform temperature fields. The mean heat transfer coefficient, h.t.c., and tube wall temperature, Tw, of the variable tube length scheme HV15(10)°‐180° are respectively 0.7% higher and 3.1 K lower than those of the normal scheme H15(10)°‐180°. The optimal relative position of the outlet and tube bundle for helical schemes is that the outlet axis is not only tangent to the last straight edge of the baffle but is also on the side near it, while the optimum outlet angle for the segmental scheme is 90° within the research scope. Compared with segmental scheme S200‐90°, the averaged heat transfer coefficients, h.t.c.s, and comprehensive indexes, h · Δp−1/3, of the helical baffle schemes HV15(10)°‐180°/HV15(10)°‐Ax respectively rise by 14.6/11.8% and 16.1/13.8%, while the average Tw declines by 40.7/33.3 K.Keywords
Funding Information
- National Natural Science Foundation of China (51776035)
This publication has 28 references indexed in Scilit:
- New insights to implement heat transfer intensification for shell and tube heat exchangersEnergy, 2013
- Thermal Conductivity of Standard Sands. Part III. Full Range of SaturationInternational Journal of Thermophysics, 2013
- Heat Transfer Enhancement in an Air Process Heater Using Semi-Circular Hollow BafflesProcedia Engineering, 2013
- Energy efficiency improvement and fuel savings in water heaters using bafflesApplied Energy, 2013
- Numerical simulation on flow field in circumferential overlap trisection helical baffle heat exchangerApplied Thermal Engineering, 2013
- 3D numerical simulation on shell-and-tube heat exchangers with middle-overlapped helical baffles and continuous baffles – Part II: Simulation results of periodic model and comparison between continuous and noncontinuous helical bafflesInternational Journal of Heat and Mass Transfer, 2009
- Numerical investigation on combined multiple shell-pass shell-and-tube heat exchanger with continuous helical bafflesInternational Journal of Heat and Mass Transfer, 2009
- Experimental and numerical heat transfer in a helically baffled heat exchanger combined with one three-dimensional finned tubeChemical Engineering and Processing - Process Intensification, 2008
- Three-Dimensional Modeling of a Helixchanger® Heat Exchanger Using CFDHeat Transfer Engineering, 2005