Yaping Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yaping Chen has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Jiafeng Wu
5 shared publications- Jiafeng Wu
School of Energy and Environment, Southeast University, Nanjing 211189, China
4 shared publications Cong Dong
Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education; School of Energy and Environment; Southeast University; Nanjing 210096 China
3 shared publications- Huaduo Gu
Department of Mechanical Engineering, The Polytechnic University of Hong Kong 1 , Hong Kong 999077
3 shared publications J. F. Wu
Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, Jiangsu Provincial Key Laboratory of Solar Energy Science and Technology, School of Energy and Environment, Southeast University, Nanjing, China
3 shared publicationsC. Dong
School of Mechanical and Automotive Engineering, Zhejiang University of Science and Technology, Hangzhou, China
2 shared publications
Latest Publications
- Open Access
- 6 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (9) , 5747
Numerical Study of Steam–CO2 Mixture Condensation over a Flat Plate Based on the Solubility of CO2
In order to successfully study the condensation and separation of a steam–CO2 mixture, a boundary layer model was applied to the mixture condensation of steam and CO2 on horizontal and vertical plates. The modified condensation boundary layer model of steam and CO2, given the CO2 solubility in the condensate, was established, numerically solved, and verified with existing experimental data. Different condensation data of steam–air and steam–CO2 mixtures were compared, and the effect of CO2 solubility on the mixed gas condensation was analyzed under multiple pressure conditions (1 atm–10 MPa). The simulation data show that the presence of CO2 will deteriorate the condensation heat transfer, just like air. Given that CO2 is slightly soluble, some CO2 can pass through the gas–liquid interface to enter the condensate film and reduce the accumulated CO2 on the gas–liquid interface, which improves the condensation. However, the solubility of CO2 is only significant under high-pressure conditions, inducing its effects on condensation. A comparison of the condensation coefficients of the steam–CO2 mixture shows the lower impact of CO2 condensation on the horizontal plate compared to that on the vertical plate. For most conditions, the steam–CO2 mixture gas condensation heat transfer coefficient on the vertical plate surface is still larger than that on the horizontal plate surface, and the improvement in the condensation heat transfer coefficient caused by low CO2 solubility (2 or 10%) at 10 MPa on the vertical plate is also larger than that of the horizontal plate.
- 6 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (9) , 5747
Open AccessNumerical Study of Steam–CO2 Mixture Condensation over a Flat Plate Based on the Solubility of CO2
In order to successfully study the condensation and separation of a steam–CO2 mixture, a boundary layer model was applied to the mixture condensation of steam and CO2 on horizontal and vertical plates. The modified condensation boundary layer model of steam and CO2, given the CO2 solubility in the condensate, was established, numerically solved, and verified with existing experimental data. Different condensation data of steam–air and steam–CO2 mixtures were compared, and the effect of CO2 solubility on the mixed gas condensation was analyzed under multiple pressure conditions (1 atm–10 MPa). The simulation data show that the presence of CO2 will deteriorate the condensation heat transfer, just like air. Given that CO2 is slightly soluble, some CO2 can pass through the gas–liquid interface to enter the condensate film and reduce the accumulated CO2 on the gas–liquid interface, which improves the condensation. However, the solubility of CO2 is only significant under high-pressure conditions, inducing its effects on condensation. A comparison of the condensation coefficients of the steam–CO2 mixture shows the lower impact of CO2 condensation on the horizontal plate compared to that on the vertical plate. For most conditions, the steam–CO2 mixture gas condensation heat transfer coefficient on the vertical plate surface is still larger than that on the horizontal plate surface, and the improvement in the condensation heat transfer coefficient caused by low CO2 solubility (2 or 10%) at 10 MPa on the vertical plate is also larger than that of the horizontal plate.
- 1 January 2023
- Published by Begell House Inc. Publishers
- p. 532-537
EXPERIMENTAL INVESTIGATION ON PROTECTING COAL PILES AGAINST SPONTANEOUS IGNITION BY DISSIPATING HEAT WITH HEAT PIPES
Based on the theory that the high temperature is one of the causes of coal oxidation, this paper presents the experimental investigation on preventing coal stockpiles against spontaneous ignition by dissipating heat and decreasing the temperature of the coal piles with heat pipes, which have the characteristics of high equivalent heat conductivity coefficient and one-way heat transfer feature. It introduces the process and the results of the site experiments, and provides the rate of heat dissipation and effective range of the heat pipes at certain ambient conditions. It also gives brief descriptions on the structure of the heat pipes and the selection of their working medium.
- 1 January 2023
- Published by Begell House Inc. Publishers
- p. 532-537
EXPERIMENTAL INVESTIGATION ON PROTECTING COAL PILES AGAINST SPONTANEOUS IGNITION BY DISSIPATING HEAT WITH HEAT PIPES
Based on the theory that the high temperature is one of the causes of coal oxidation, this paper presents the experimental investigation on preventing coal stockpiles against spontaneous ignition by dissipating heat and decreasing the temperature of the coal piles with heat pipes, which have the characteristics of high equivalent heat conductivity coefficient and one-way heat transfer feature. It introduces the process and the results of the site experiments, and provides the rate of heat dissipation and effective range of the heat pipes at certain ambient conditions. It also gives brief descriptions on the structure of the heat pipes and the selection of their working medium.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Experimental Study on the Alleviation of Thermal Runaway Propagation from an Overcharged Lithium-Ion Battery Module Using Different Thermal Insulation Layers
An efficient and safe thermal insulation structure design is critical in battery thermal management systems to prevent thermal runaway propagation. In this paper, using a common real-life overcharge as a trigger for battery runaway, we investigate the runaway response of the battery module without thermal insulation and with various thermal insulation materials. The experimental results indicate that the thermal insulation has the effect of stopping the thermal spread of the battery module and reducing the maximum temperature. By comparing the temperature change of the batteries, it is discovered that the fiber-based material has a temperature drop efficiency of 71.83%, while the aerogel materials are at least 13% more efficient in temperature reduction than fibrous materials. Meanwhile, it is demonstrated that by examining the capacity characteristics of the damaged battery and the characteristics of the insulation material, the pre-oxidized silk aerogel has the best thermal spread suppression effect and the TG (thermogravimetric) variation withstood high temperatures of up to 746 °C. SEM (scanning electron microscope) morphology for different insulation materials before and after combustion show that Pre-oxidized silk aerogel maintains a strong thermal insulation capacity in the thermal spreading.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessExperimental Study on the Alleviation of Thermal Runaway Propagation from an Overcharged Lithium-Ion Battery Module Using Different Thermal Insulation Layers
An efficient and safe thermal insulation structure design is critical in battery thermal management systems to prevent thermal runaway propagation. In this paper, using a common real-life overcharge as a trigger for battery runaway, we investigate the runaway response of the battery module without thermal insulation and with various thermal insulation materials. The experimental results indicate that the thermal insulation has the effect of stopping the thermal spread of the battery module and reducing the maximum temperature. By comparing the temperature change of the batteries, it is discovered that the fiber-based material has a temperature drop efficiency of 71.83%, while the aerogel materials are at least 13% more efficient in temperature reduction than fibrous materials. Meanwhile, it is demonstrated that by examining the capacity characteristics of the damaged battery and the characteristics of the insulation material, the pre-oxidized silk aerogel has the best thermal spread suppression effect and the TG (thermogravimetric) variation withstood high temperatures of up to 746 °C. SEM (scanning electron microscope) morphology for different insulation materials before and after combustion show that Pre-oxidized silk aerogel maintains a strong thermal insulation capacity in the thermal spreading.
- 22 February 2020
- Published by Emerald Publishing in Engineering Computations
- Vol. 37 (7) , 2213-2227
Simulation on heat transfer performances of hollow tube electric heaters with dual-side longitudinal flow
Purpose: Conventional electric heaters mostly use U-shaped electric heating tubes and the hollow tube electric heaters are new type ones that rely on the heat transfer tubes as heating elements. However, in the original design, the fluid flows through the annular gaps between the shell wall and the supporting plates, the chambers between supporting plates are generally stagnant zones. The purpose of study is to overcome these deficiencies. Design/methodology/approach: A modified approach is proposed in which the heating tubes are surrounded by holes on the supporting plates, thus the stagnant flow zone can be eliminated and the heating surfaces of both inside and outside the tube can be fully used. Numerical simulations were carried out on four schemes of hollow tube electric heaters, i.e. plate blocked, countercurrent, parallel and split. The results show that the two schemes of parallel and split can reduce the temperature difference between the two sides of the fixed tube plate, and thus reduce thermal stress and prolong the service life. Findings: The split scheme of electric heater has the highest comprehensive index, moderate heat transfer coefficient and minimum pressure drop on the shell side. Its average heat transfer coefficient and comprehensive index are, respectively, 15.7% and 52.9% higher and its average pressure drop and tube wall temperature are, respectively, 57.6% and 19 K lower than those of the original plate blocked scheme, thus it can be recommended as the best scheme of the hollow tube electric heaters. Originality/value: Based on the original design of hollow tube electric heater with plate blocked scheme, three plate perforated schemes were proposed and investigated. The thermal and flow features of the four schemes were compared in terms of heat transfer coefficient, pressure drop and comprehensive index ho·Δpo−1/3. The split scheme can reduce the temperature difference between two sides of the fixed tube plate with reduced thermal stress. It has moderate tube wall temperature and heat transfer coefficient, the smallest shell side pressure drop and the highest comprehensive index ho·Δpo−1/3, and it can be recommended as the optimal scheme.
- 22 February 2020
- Published by Emerald Publishing in Engineering Computations
- Vol. 37 (7) , 2213-2227
Simulation on heat transfer performances of hollow tube electric heaters with dual-side longitudinal flow
Purpose: Conventional electric heaters mostly use U-shaped electric heating tubes and the hollow tube electric heaters are new type ones that rely on the heat transfer tubes as heating elements. However, in the original design, the fluid flows through the annular gaps between the shell wall and the supporting plates, the chambers between supporting plates are generally stagnant zones. The purpose of study is to overcome these deficiencies. Design/methodology/approach: A modified approach is proposed in which the heating tubes are surrounded by holes on the supporting plates, thus the stagnant flow zone can be eliminated and the heating surfaces of both inside and outside the tube can be fully used. Numerical simulations were carried out on four schemes of hollow tube electric heaters, i.e. plate blocked, countercurrent, parallel and split. The results show that the two schemes of parallel and split can reduce the temperature difference between the two sides of the fixed tube plate, and thus reduce thermal stress and prolong the service life. Findings: The split scheme of electric heater has the highest comprehensive index, moderate heat transfer coefficient and minimum pressure drop on the shell side. Its average heat transfer coefficient and comprehensive index are, respectively, 15.7% and 52.9% higher and its average pressure drop and tube wall temperature are, respectively, 57.6% and 19 K lower than those of the original plate blocked scheme, thus it can be recommended as the best scheme of the hollow tube electric heaters. Originality/value: Based on the original design of hollow tube electric heater with plate blocked scheme, three plate perforated schemes were proposed and investigated. The thermal and flow features of the four schemes were compared in terms of heat transfer coefficient, pressure drop and comprehensive index ho·Δpo−1/3. The split scheme can reduce the temperature difference between two sides of the fixed tube plate with reduced thermal stress. It has moderate tube wall temperature and heat transfer coefficient, the smallest shell side pressure drop and the highest comprehensive index ho·Δpo−1/3, and it can be recommended as the optimal scheme.
- 19 November 2019
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 98 (4) , 1017-1030
Influence of outlet orientation and variable tube length on high temperature zones of U‐tube trisection helical baffle electric heaters
Numerical simulation was performed to optimize temperature distribution especially at high temperature zones at the rear part of U‐tube bundle electric heaters with unique one‐plus‐two U‐tube layouts. The influences of variable tube lengths and different outlet nozzle orientations on flow and thermal features on axial separation trisection helical baffle schemes in contrast to segmental schemes were investigated. The results show that the variable tube length schemes can effectively ameliorate high temperature zones and obtain more uniform temperature fields. The mean heat transfer coefficient, h.t.c., and tube wall temperature, Tw, of the variable tube length scheme HV15(10)°‐180° are respectively 0.7% higher and 3.1 K lower than those of the normal scheme H15(10)°‐180°. The optimal relative position of the outlet and tube bundle for helical schemes is that the outlet axis is not only tangent to the last straight edge of the baffle but is also on the side near it, while the optimum outlet angle for the segmental scheme is 90° within the research scope. Compared with segmental scheme S200‐90°, the averaged heat transfer coefficients, h.t.c.s, and comprehensive indexes, h · Δp−1/3, of the helical baffle schemes HV15(10)°‐180°/HV15(10)°‐Ax respectively rise by 14.6/11.8% and 16.1/13.8%, while the average Tw declines by 40.7/33.3 K.
- 19 November 2019
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 98 (4) , 1017-1030
Influence of outlet orientation and variable tube length on high temperature zones of U‐tube trisection helical baffle electric heaters
Numerical simulation was performed to optimize temperature distribution especially at high temperature zones at the rear part of U‐tube bundle electric heaters with unique one‐plus‐two U‐tube layouts. The influences of variable tube lengths and different outlet nozzle orientations on flow and thermal features on axial separation trisection helical baffle schemes in contrast to segmental schemes were investigated. The results show that the variable tube length schemes can effectively ameliorate high temperature zones and obtain more uniform temperature fields. The mean heat transfer coefficient, h.t.c., and tube wall temperature, Tw, of the variable tube length scheme HV15(10)°‐180° are respectively 0.7% higher and 3.1 K lower than those of the normal scheme H15(10)°‐180°. The optimal relative position of the outlet and tube bundle for helical schemes is that the outlet axis is not only tangent to the last straight edge of the baffle but is also on the side near it, while the optimum outlet angle for the segmental scheme is 90° within the research scope. Compared with segmental scheme S200‐90°, the averaged heat transfer coefficients, h.t.c.s, and comprehensive indexes, h · Δp−1/3, of the helical baffle schemes HV15(10)°‐180°/HV15(10)°‐Ax respectively rise by 14.6/11.8% and 16.1/13.8%, while the average Tw declines by 40.7/33.3 K.