Can real-time RGBD enhance intraoperative Cone-Beam CT?
Authors:
- 25 March 2017
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 12 (7) , 1211-1219
Abstract
Purpose Cone-Beam Computed Tomography (CBCT) is an important 3D imaging technology for orthopedic, trauma, radiotherapy guidance, angiography, and dental applications. The major limitation of CBCT is the poor image quality due to scattered radiation, truncation, and patient movement. In this work, we propose to incorporate information from a co-registered Red-Green-Blue-Depth (RGBD) sensor attached near the detector plane of the C-arm to improve the reconstruction quality, as well as correcting for undesired rigid patient movement. Methods Calibration of the RGBD and C-arm imaging devices is performed in two steps: (i) calibration of the RGBD sensor and the X-ray source using a multimodal checkerboard pattern, and (ii) calibration of the RGBD surface reconstruction to the CBCT volume. The patient surface is acquired during the CBCT scan and then used as prior information for the reconstruction using Maximum-Likelihood Expectation-Maximization. An RGBD-based simultaneous localization and mapping method is utilized to estimate the rigid patient movement during scanning. Results Performance is quantified and demonstrated using artificial data and bone phantoms with and without metal implants. Finally, we present movement-corrected CBCT reconstructions based on RGBD data on an animal specimen, where the average voxel intensity difference reduces from 0.157 without correction to 0.022 with correction. Conclusion This work investigated the advantages of a C-arm X-ray imaging system used with an attached RGBD sensor. The experiments show the benefits of the opto/X-ray imaging system in: (i) improving the quality of reconstruction by incorporating the surface information of the patient, reducing the streak artifacts as well as the number of required projections, and (ii) recovering the scanning trajectory for the reconstruction in the presence of undesired patient rigid movement.Keywords
Funding Information
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (T32AR067708)
This publication has 28 references indexed in Scilit:
- Iterative reconstruction methods in X-ray CTPhysica Medica, 2012
- C-Arm Cone-Beam CT-Guided Percutaneous Transthoracic Lung Biopsy: Usefulness in Evaluation of Small Pulmonary NodulesAmerican Journal of Roentgenology, 2010
- Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility StudyAmerican Journal of Roentgenology, 2009
- C-arm Cone Beam Computed Tomographic Needle Path Overlay for Fluoroscopic-Guided Placement of Translumbar Central Venous CathetersCardioVascular and Interventional Radiology, 2009
- Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimizationPhysics in Medicine & Biology, 2008
- C-arm Cone-beam CT: General Principles and Technical Considerations for Use in Interventional RadiologyJournal of Vascular and Interventional Radiology, 2008
- Statistical Image Reconstruction for Inconsistent CT Projection DataMethods of Information in Medicine, 2007
- A flexible new technique for camera calibrationIEEE Transactions on Pattern Analysis and Machine Intelligence, 2000
- Algebraic reconstruction in CT from limited viewsIEEE Transactions on Medical Imaging, 1989
- Algebraic Reconstruction Techniques (ART) for three-dimensional electron microscopy and X-ray photographyJournal of Theoretical Biology, 1970