JFJavad Fotouhi

Javad Fotouhi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Javad Fotouhi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Bernhard Fuerst

    Computer Aided Medical Procedures, Johns Hopkins University, Baltimore, MD, USA

    2 shared publications
  • Nassir Navab

    Computer Aided Medical Procedures, Johns Hopkins University, Baltimore, MD, USA

    2 shared publications
  • Alex Johnson

    Department of Orthopaedic Surgery, Johns Hopkins Hospital, Baltimore, MD, USA

    1 shared publication
  • Greg Osgood

    Department of Orthopaedic Surgery, Johns Hopkins Hospital, Baltimore, MD, USA

    1 shared publication
  • Mehran Armand

    Department of Orthopaedic Surgery, Johns Hopkins Hospital, Baltimore, MD, USA

    1 shared publication
  • Russell Taylor

    Department of Computer Science, Johns Hopkins University, Baltimore, MD, USA

    1 shared publication

Latest Publications

  • Pose-aware C-arm for automatic re-initialization of interventional 2D/3D image registration

    by Javad Fotouhi, Bernhard Fuerst, Alex Johnson, Sing Chun Lee, Russell Taylor, Greg Osgood, Nassir Navab, Mehran Armand

    Purpose In minimally invasive interventions assisted by C-arm imaging, there is a demand to fuse the intra-interventional 2D C-arm image with pre-interventional 3D patient data to enable surgical guidance. The commonly used intensity-based 2D/3D registration has a limited capture range and is sensitive to initialization. We propose to utilize an opto/X-ray C-arm system which allows to maintain the registration during intervention by automating the re-initialization for the 2D/3D image registration. Consequently, the surgical workflow is not disrupted and the interaction time for manual initialization is eliminated. Methods We utilize two distinct vision-based tracking techniques to estimate the relative poses between different C-arm arrangements: (1) global tracking using fused depth information and (2) RGBD SLAM system for surgical scene tracking. A highly accurate multi-view calibration between RGBD and C-arm imaging devices is achieved using a custom-made multimodal calibration target. Results Several in vitro studies are conducted on pelvic-femur phantom that is encased in gelatin and covered with drapes to simulate a clinically realistic scenario. The mean target registration errors (mTRE) for re-initialization using depth-only and RGB \(+\) depth are 13.23 mm and 11.81 mm, respectively. 2D/3D registration yielded 75% success rate using this automatic re-initialization, compared to a random initialization which yielded only 23% successful registration. Conclusion The pose-aware C-arm contributes to the 2D/3D registration process by globally re-initializing the relationship of C-arm image and pre-interventional CT data. This system performs inside-out tracking, is self-contained, and does not require any external tracking devices.


  • Can real-time RGBD enhance intraoperative Cone-Beam CT?

    by Javad Fotouhi, Bernhard Fuerst, Wolfgang Wein, Nassir Navab

    Purpose Cone-Beam Computed Tomography (CBCT) is an important 3D imaging technology for orthopedic, trauma, radiotherapy guidance, angiography, and dental applications. The major limitation of CBCT is the poor image quality due to scattered radiation, truncation, and patient movement. In this work, we propose to incorporate information from a co-registered Red-Green-Blue-Depth (RGBD) sensor attached near the detector plane of the C-arm to improve the reconstruction quality, as well as correcting for undesired rigid patient movement. Methods Calibration of the RGBD and C-arm imaging devices is performed in two steps: (i) calibration of the RGBD sensor and the X-ray source using a multimodal checkerboard pattern, and (ii) calibration of the RGBD surface reconstruction to the CBCT volume. The patient surface is acquired during the CBCT scan and then used as prior information for the reconstruction using Maximum-Likelihood Expectation-Maximization. An RGBD-based simultaneous localization and mapping method is utilized to estimate the rigid patient movement during scanning. Results Performance is quantified and demonstrated using artificial data and bone phantoms with and without metal implants. Finally, we present movement-corrected CBCT reconstructions based on RGBD data on an animal specimen, where the average voxel intensity difference reduces from 0.157 without correction to 0.022 with correction. Conclusion This work investigated the advantages of a C-arm X-ray imaging system used with an attached RGBD sensor. The experiments show the benefits of the opto/X-ray imaging system in: (i) improving the quality of reconstruction by incorporating the surface information of the patient, reducing the streak artifacts as well as the number of required projections, and (ii) recovering the scanning trajectory for the reconstruction in the presence of undesired patient rigid movement.