Ultralow Dose MSCT Imaging in Dental Implantology
Authors:
Open Access
- 31 January 2018
- journal article
- review article
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 12 (1) , 87-93
Abstract
The Council Directive 2013/59 Euratom has a clear commitment for keeping medical radiation exposure as low as reasonably achievable and demands a regular review and use of diagnostic reference levels. In dental implantology, the range of effective doses for cone beam computed tomography (CBCT) shows a broad overlap with multislice computed tomography (MSCT). More recently, ultralow dose imaging with new generations of MSCT scanners may impart radiation doses equal to or lower than CBCT. Dose reductions in MSCT have been further facilitated by the introduction of iterative image reconstruction technology (IRT), which provides substantial noise reduction over the current standard of filtered backward projection (FBP). The aim of this article is to review the available literature on ultralow dose CT imaging and IRTs in dental implantology imaging and to summarize their influence on spatial and contrast resolution, image noise, tissue density measurements, and validity of linear measurements of the jaws. Application of ultralow dose MSCT with IRT technology in dental implantology offers the potential for very large dose reductions compared with standard dose imaging. Yet, evaluation of various diagnostic tasks related to dental implantology is still needed to confirm the results obtained with various IRTs and ultra-low doses so far.Keywords
This publication has 35 references indexed in Scilit:
- Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sitesEuropean Radiology, 2016
- Validity of linear measurements of the jaws using ultralow-dose MDCT and the iterative techniques of ASIR and MBIRInternational Journal of Computer Assisted Radiology and Surgery, 2016
- Seventy kilovolt ultra-low dose CT of the paranasal sinus: first clinical resultsClinical Radiology, 2015
- Ultralow-Dose CT of the Craniofacial Bone for Navigated Surgery Using Adaptive Statistical Iterative Reconstruction and Model-Based Iterative Reconstruction: 2D and 3D Image QualityAmerican Journal of Roentgenology, 2015
- CBCT-based bone quality assessment: are Hounsfield units applicable?Dentomaxillofacial Radiology, 2015
- Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CTImaging Science in Dentistry, 2012
- Innovations in CT Dose Reduction Strategy: Application of the Adaptive Statistical Iterative Reconstruction AlgorithmAmerican Journal of Roentgenology, 2010
- Radiation dose vs. image quality for low-dose CT protocols of the head for maxillofacial surgery and oral implant planningRadiation Protection Dosimetry, 2005
- Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement: a clinical study.2005
- Eine einfache Methode zur Abschätzung der effektiven Dosis bei Dental-CT. Konversionsfaktoren und exemplarische Berechnung für ein klinisches Low-Dose-ProtokollRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2001