Simulation Based Design and Evaluation of a Transcatheter Mitral Heart Valve Frame
- 14 August 2012
- journal article
- research article
- Published by ASME International in Journal of Medical Devices
- Vol. 6 (3) , 031005-031012
Abstract
In certain populations, open heart surgery to replace a diseased mitral valve is not an option, leaving percutaneous delivery a viable alternative. However, a surgical transcatheter based delivery of a metallic support frame incorporating a tissue derived valve puts considerable constraints on device specifications. Expansion to a large diameter from the catheter diameter without mechanical fracture involves advanced device design and appropriate material processing and selection. In this study, a new frame concept is presented with a desirable feature that incorporates wings that protrude during expansion to establish adequate fixation. Expansion characteristics of the design in relation to annulus fixation were quantified through finite element analysis predictions of the frame wing span and angles. Computational modeling and simulation was used to identify many favorable design features for the transcatheter mitral valve frame and obtain desired expansion diameters (35–45 mm), acceptable radial stiffness (2.7 N/mm), and ensure limited risk of failure based on predicted plastic deformations.Keywords
This publication has 31 references indexed in Scilit:
- Mechanistic Insights into Ischemic Mitral Regurgitation: Echocardiographic and Surgical ImplicationsJournal of the American Society of Echocardiography, 2011
- Mitral valved stent implantation: An overviewMinimally Invasive Therapy & Allied Technologies, 2011
- Relationship between mitral leaflets angles, left ventricular geometry and mitral deformation indices in patients with ischemic mitral regurgitation: imaging by echocardiography and cardiac magnetic resonanceThe International Journal of Cardiovascular Imaging, 2011
- Characterization of Degenerative Mitral Valve Disease Using Morphologic Analysis of Real-Time Three-Dimensional Echocardiographic ImagesCirculation: Cardiovascular Imaging, 2011
- Off-pump transapical mitral valve replacement☆European Journal of Cardio-Thoracic Surgery, 2009
- Minimally invasive off-pump valve-in-a-ring implantation: the atrial transcatheter approach for re-operative mitral valve replacement after failed repairEuropean Journal of Cardio-Thoracic Surgery, 2009
- Mitral Annulus Calcification is associated with valvular and cardiac structural abnormalitiesCardiovascular Ultrasound, 2007
- In Vivo Analysis of the Anatomical Relationship of Coronary Sinus to Mitral Annulus and Left Circumflex Coronary Artery Using Cardiac Multidetector Computed TomographyJACC, 2006
- Percutaneous valve repair and replacement techniquesHeart, 2006
- Size and motion of the mitral valve annulus in man. I. A two-dimensional echocardiographic method and findings in normal subjects.Circulation, 1981