Ryan Klatte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ryan Klatte has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Stephan Weber
Lerner Research Institute, Department of Biomedical Engineering, Cleveland Clinic, Cleveland, OH, USA
10 shared publicationsKiyotaka Fukamachi
8 shared publicationsViviane Luangphakdy
8 shared publicationsWilliam A. Smith
Lerner Research Institute, Department of Biomedical Engineering, Cleveland Clinic, Cleveland, OH, USA
8 shared publicationsYoshio Ootaki
Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
7 shared publicationsKeiji Kamohara
Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
6 shared publications
Latest Publications
- Open Access
- 31 May 2026
- Published by MDPI AG in Lymphatics
- Vol. 4 (2) , 29
Three-Dimensional Stereolithography in Robotic Lymph Node-to-Vein Anastomosis: Precision, Efficiency, and Scalability
Lymph node-to-vein anastomosis (LNVA) is an emerging physiologic treatment for fluid-predominant lymphedema that combines the efficacy of lymphatic bypass with reduced technical complexity. Despite its advantages, LNVA is limited by challenges in identifying suitable lymph nodes and recipient veins. This study evaluated whether three-dimensional stereolithography (SLA) could improve surgical planning, intraoperative navigation, and efficiency in robotic LNVA. A retrospective comparative study was conducted of 29 patients who underwent robotic inguinal LNVA between November 2024 and September 2025. Thirteen procedures were performed using standard robotic LNVA (control group), and sixteen were performed with the addition of SLA-assisted planning and navigation (study group). Patient-specific SLA models were created from contrast-enhanced CT data, segmented into lymph nodes, veins, arteries, and bony landmarks, and printed at 1:1 scale for incision planning and real-time intraoperative reference. Outcome measures included operative time, time to identification of target structures (TITS), surgeon-perceived operative difficulty (SPOD), and early patient-reported outcomes. Mean operative time was similar between groups (171 vs. 161 min), but TITS was significantly shorter with SLA (36 vs. 27 min; p = 0.021). Double LNVA was achieved in 69% of SLA cases compared with 8% of controls, without prolonging operative duration. SPOD was significantly lower in the SLA group (p < 0.001). All anastomoses were patent intraoperatively, and all patients reported symptom relief at one month. Model fabrication required approximately eight hours and averaged $270 per case. Stereolithography enhances robotic LNVA by providing a tangible three-dimensional roadmap that improves intraoperative orientation, reduces identification time, and enables multiple anastomoses without added operative burden. With modest cost and rapid production, SLA makes LNVA more precise, reproducible, and scalable—facilitating wider adoption and serving as a foundation for future outcome-based research.
- 31 May 2026
- Published by MDPI AG in Lymphatics
- Vol. 4 (2) , 29
Open AccessThree-Dimensional Stereolithography in Robotic Lymph Node-to-Vein Anastomosis: Precision, Efficiency, and Scalability
Lymph node-to-vein anastomosis (LNVA) is an emerging physiologic treatment for fluid-predominant lymphedema that combines the efficacy of lymphatic bypass with reduced technical complexity. Despite its advantages, LNVA is limited by challenges in identifying suitable lymph nodes and recipient veins. This study evaluated whether three-dimensional stereolithography (SLA) could improve surgical planning, intraoperative navigation, and efficiency in robotic LNVA. A retrospective comparative study was conducted of 29 patients who underwent robotic inguinal LNVA between November 2024 and September 2025. Thirteen procedures were performed using standard robotic LNVA (control group), and sixteen were performed with the addition of SLA-assisted planning and navigation (study group). Patient-specific SLA models were created from contrast-enhanced CT data, segmented into lymph nodes, veins, arteries, and bony landmarks, and printed at 1:1 scale for incision planning and real-time intraoperative reference. Outcome measures included operative time, time to identification of target structures (TITS), surgeon-perceived operative difficulty (SPOD), and early patient-reported outcomes. Mean operative time was similar between groups (171 vs. 161 min), but TITS was significantly shorter with SLA (36 vs. 27 min; p = 0.021). Double LNVA was achieved in 69% of SLA cases compared with 8% of controls, without prolonging operative duration. SPOD was significantly lower in the SLA group (p < 0.001). All anastomoses were patent intraoperatively, and all patients reported symptom relief at one month. Model fabrication required approximately eight hours and averaged $270 per case. Stereolithography enhances robotic LNVA by providing a tangible three-dimensional roadmap that improves intraoperative orientation, reduces identification time, and enables multiple anastomoses without added operative burden. With modest cost and rapid production, SLA makes LNVA more precise, reproducible, and scalable—facilitating wider adoption and serving as a foundation for future outcome-based research.
- Open Access
- 28 March 2015
- Published by Springer Nature in Medical Science Educator
- Vol. 25 (2) , 183-194
Anatomical Models: a Digital Revolution
- 28 March 2015
- Published by Springer Nature in Medical Science Educator
- Vol. 25 (2) , 183-194
Open AccessAnatomical Models: a Digital Revolution
- 1 August 2014
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 28 (4) , 1122-1125
Novel Application of Rapid Prototyping for Simulation of Bronchoscopic Anatomy
- 1 August 2014
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 28 (4) , 1122-1125
Novel Application of Rapid Prototyping for Simulation of Bronchoscopic Anatomy
- Open Access
- 1 January 2014
- Published by Elsevier in Redox Biology
- Vol. 2, 513-519
A novel method for pulmonary research: Assessment of bioenergetic function at the air–liquid interface
- 1 January 2014
- Published by Elsevier in Redox Biology
- Vol. 2, 513-519
Open AccessA novel method for pulmonary research: Assessment of bioenergetic function at the air–liquid interface
- Top Cited Papers
- 1 December 2013
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 19 (12) , 1304-1310
Three-dimensional print of a liver for preoperative planning in living donor liver transplantation
The growing demand for liver transplantation and the concomitant scarcity of cadaveric livers have increased the need for living donor liver transplantation (LDLT). Ensuring the safety of donors and recipients is critical. The preoperative identification of the vascular and biliary tract anatomy with 3-dimensional (3D) printing may allow better preoperative surgical planning, avert unnecessary surgery in patients with potentially unsuitable anatomy, and thereby decrease the complications of liver transplant surgery. We developed a protocol and successfully 3D-printed synthetic livers (along with their complex networks of vascular and biliary structures) replicating the native livers of 6 patients: 3 living donors and 3 respective recipients who underwent LDLT. To our knowledge, these are the first complete 3D-printed livers. Using standardized preoperative, intraoperative, and postoperative assessments, we demonstrated identical anatomical and geometrical landmarks in the 3D-printed models and native livers. Liver Transpl 19:1304–1310, 2013. © 2013 AASLD.
- 1 December 2013
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 19 (12) , 1304-1310
Top Cited PapersThree-dimensional print of a liver for preoperative planning in living donor liver transplantation
The growing demand for liver transplantation and the concomitant scarcity of cadaveric livers have increased the need for living donor liver transplantation (LDLT). Ensuring the safety of donors and recipients is critical. The preoperative identification of the vascular and biliary tract anatomy with 3-dimensional (3D) printing may allow better preoperative surgical planning, avert unnecessary surgery in patients with potentially unsuitable anatomy, and thereby decrease the complications of liver transplant surgery. We developed a protocol and successfully 3D-printed synthetic livers (along with their complex networks of vascular and biliary structures) replicating the native livers of 6 patients: 3 living donors and 3 respective recipients who underwent LDLT. To our knowledge, these are the first complete 3D-printed livers. Using standardized preoperative, intraoperative, and postoperative assessments, we demonstrated identical anatomical and geometrical landmarks in the 3D-printed models and native livers. Liver Transpl 19:1304–1310, 2013. © 2013 AASLD.
- 14 August 2012
- Published by ASME International in Journal of Medical Devices
- Vol. 6 (3) , 031005-031012
Simulation Based Design and Evaluation of a Transcatheter Mitral Heart Valve Frame
In certain populations, open heart surgery to replace a diseased mitral valve is not an option, leaving percutaneous delivery a viable alternative. However, a surgical transcatheter based delivery of a metallic support frame incorporating a tissue derived valve puts considerable constraints on device specifications. Expansion to a large diameter from the catheter diameter without mechanical fracture involves advanced device design and appropriate material processing and selection. In this study, a new frame concept is presented with a desirable feature that incorporates wings that protrude during expansion to establish adequate fixation. Expansion characteristics of the design in relation to annulus fixation were quantified through finite element analysis predictions of the frame wing span and angles. Computational modeling and simulation was used to identify many favorable design features for the transcatheter mitral valve frame and obtain desired expansion diameters (35–45 mm), acceptable radial stiffness (2.7 N/mm), and ensure limited risk of failure based on predicted plastic deformations.
- 14 August 2012
- Published by ASME International in Journal of Medical Devices
- Vol. 6 (3) , 031005-031012
Simulation Based Design and Evaluation of a Transcatheter Mitral Heart Valve Frame
In certain populations, open heart surgery to replace a diseased mitral valve is not an option, leaving percutaneous delivery a viable alternative. However, a surgical transcatheter based delivery of a metallic support frame incorporating a tissue derived valve puts considerable constraints on device specifications. Expansion to a large diameter from the catheter diameter without mechanical fracture involves advanced device design and appropriate material processing and selection. In this study, a new frame concept is presented with a desirable feature that incorporates wings that protrude during expansion to establish adequate fixation. Expansion characteristics of the design in relation to annulus fixation were quantified through finite element analysis predictions of the frame wing span and angles. Computational modeling and simulation was used to identify many favorable design features for the transcatheter mitral valve frame and obtain desired expansion diameters (35–45 mm), acceptable radial stiffness (2.7 N/mm), and ensure limited risk of failure based on predicted plastic deformations.
- 18 November 2010
- Published by Wiley in Artificial Organs
- Vol. 35 (2) , 188-191
Cycle Testing of the MagScrew Total Artificial Heart External Battery Pack: Update I
MagScrew total artificial heart (TAH) external battery pack (EBP) cycle bench testing continued over a period of 18 months using two fresh Wilson Greatbatch lithium ion EBPs during continuous charge and discharge cycles under a simulated TAH system current requirement. The same electronic load developed for our initial testing was used to simulate the MagScrew current waveforms typically observed during nominal operation. The current load profiles for this test were modified from the ones previously described and applied to the EBP under test during a voltage-defined discharge cycle. The test ended when EBP#2 reached end of life at 1450 cycles. At that point, EBP#1 remained healthy with a capacity of 175 min until full discharge. Performance of EBP#2 was still within expected ranges. Performance of EBP#1 exceeded expectations. These differences are probably caused by slight manufacturing changes. More tests will provide additional data to define a statistical distribution to better characterize EBP performance. In conclusion, endurance performance of the EBP remained satisfactory.
- 18 November 2010
- Published by Wiley in Artificial Organs
- Vol. 35 (2) , 188-191
Cycle Testing of the MagScrew Total Artificial Heart External Battery Pack: Update I
MagScrew total artificial heart (TAH) external battery pack (EBP) cycle bench testing continued over a period of 18 months using two fresh Wilson Greatbatch lithium ion EBPs during continuous charge and discharge cycles under a simulated TAH system current requirement. The same electronic load developed for our initial testing was used to simulate the MagScrew current waveforms typically observed during nominal operation. The current load profiles for this test were modified from the ones previously described and applied to the EBP under test during a voltage-defined discharge cycle. The test ended when EBP#2 reached end of life at 1450 cycles. At that point, EBP#1 remained healthy with a capacity of 175 min until full discharge. Performance of EBP#2 was still within expected ranges. Performance of EBP#1 exceeded expectations. These differences are probably caused by slight manufacturing changes. More tests will provide additional data to define a statistical distribution to better characterize EBP performance. In conclusion, endurance performance of the EBP remained satisfactory.
- 1 November 2010
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 90 (5) , 1682-1687
Performance of Extracorporeally Adjustable Ventricular Assist Device Inflow Cannula
- 1 November 2010
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 90 (5) , 1682-1687
Performance of Extracorporeally Adjustable Ventricular Assist Device Inflow Cannula
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3214-3216
Design and simulation study of low-cost 511 keV SPECT/CT imaging of PET tracers in mice
A collimation device for 511 keV small animal SPECT/CT using clinical detectors was investigated as an alternative to dedicated PET/CT. The device consists of a 45 mm thick collimator (lead cylinder with 30 tungsten pinhole inserts) and an animal bed with three-degrees-of-freedom. The device rests on the patient bed of a clinical SPECT/CT scanner, where the gamma cameras rotate around the collimator. The cylinder and pinhole inserts (1.5 mm diameter aperture and 15° cone angle) were designed to provide adequate line-of-sight shielding of 511 keV gamma rays and minimal pinhole penetration. Monte Carlo simulations were performed to evaluate the shielding and imaging performance. Gamma ray leakage was mainly through the pinhole cones rather than the lead cylinder. At the center of the field of view, spatial resolution was estimated to be 2.2 mm, and sensitivity was 0.20% with dual 15.9 mm thick NaI(Tl) detectors. Although the performance is below that of a state-of-the-art small animal PET/CT scanner, this device may be an acceptable low-cost alternative for some laboratories.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3214-3216
Design and simulation study of low-cost 511 keV SPECT/CT imaging of PET tracers in mice
A collimation device for 511 keV small animal SPECT/CT using clinical detectors was investigated as an alternative to dedicated PET/CT. The device consists of a 45 mm thick collimator (lead cylinder with 30 tungsten pinhole inserts) and an animal bed with three-degrees-of-freedom. The device rests on the patient bed of a clinical SPECT/CT scanner, where the gamma cameras rotate around the collimator. The cylinder and pinhole inserts (1.5 mm diameter aperture and 15° cone angle) were designed to provide adequate line-of-sight shielding of 511 keV gamma rays and minimal pinhole penetration. Monte Carlo simulations were performed to evaluate the shielding and imaging performance. Gamma ray leakage was mainly through the pinhole cones rather than the lead cylinder. At the center of the field of view, spatial resolution was estimated to be 2.2 mm, and sensitivity was 0.20% with dual 15.9 mm thick NaI(Tl) detectors. Although the performance is below that of a state-of-the-art small animal PET/CT scanner, this device may be an acceptable low-cost alternative for some laboratories.
- 24 August 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (18) , 5363-5381
A fillable micro-hollow sphere lesion detection phantom using superposition
The lesion detection performance of SPECT and PET scanners is most commonly evaluated with a phantom containing hollow spheres in a background chamber at a specified radionuclide contrast ratio. However, there are limitations associated with a miniature version of a hollow sphere phantom for small-animal SPECT and PET scanners. One issue is that the 'wall effect' associated with zero activity in the sphere wall and fill port causes significant errors for small diameter spheres. Another issue is that there are practical difficulties in fabricating and in filling very small spheres (<3 mm diameter). The need for lesion detection performance assessment of small-animal scanners has motivated our development of a micro-hollow sphere phantom that utilizes the principle of superposition. The phantom is fabricated by stereolithography and has interchangeable sectors containing hollow spheres with volumes ranging from 1 to 14 microL (diameters ranging from 1.25 to 3.0 mm). A simple 60 degrees internal rotation switches the positions of three such sectors with their corresponding background regions. Raw data from scans of each rotated configuration are combined and reconstructed to yield superposition images. Since the sphere counts and background counts are acquired separately, the wall effect is eliminated. The raw data are subsampled randomly prior to summation and reconstruction to specify the desired sphere-to-background contrast ratio of the superposition image. A set of images with multiple contrast ratios is generated for visual assessment of lesion detection thresholds. To demonstrate the utility of the phantom, data were acquired with a multi-pinhole SPECT/CT scanner. Micro-liter syringes were successful in filling the small hollow spheres, and the accuracy of the dispensed volume was validated through repeated filling and weighing of the spheres. The phantom's internal rotation and the data analysis process were successful in producing the expected superposition images. Visual inspection of the multi-contrast images provided simple determination of lesion detection thresholds for this scanner (4:1 ratio for 1.5 mm spheres and 3:1 ratio for 2.0 mm spheres) at a specified cumulated background concentration (30 kBq-min microL(-1)). In summary, the micro-hollow sphere phantom demonstrated its practical utility for lesion detection evaluation and is well suited for comparing the task-based performance of small-animal SPECT and PET scanners.
- 24 August 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (18) , 5363-5381
A fillable micro-hollow sphere lesion detection phantom using superposition
The lesion detection performance of SPECT and PET scanners is most commonly evaluated with a phantom containing hollow spheres in a background chamber at a specified radionuclide contrast ratio. However, there are limitations associated with a miniature version of a hollow sphere phantom for small-animal SPECT and PET scanners. One issue is that the 'wall effect' associated with zero activity in the sphere wall and fill port causes significant errors for small diameter spheres. Another issue is that there are practical difficulties in fabricating and in filling very small spheres (<3 mm diameter). The need for lesion detection performance assessment of small-animal scanners has motivated our development of a micro-hollow sphere phantom that utilizes the principle of superposition. The phantom is fabricated by stereolithography and has interchangeable sectors containing hollow spheres with volumes ranging from 1 to 14 microL (diameters ranging from 1.25 to 3.0 mm). A simple 60 degrees internal rotation switches the positions of three such sectors with their corresponding background regions. Raw data from scans of each rotated configuration are combined and reconstructed to yield superposition images. Since the sphere counts and background counts are acquired separately, the wall effect is eliminated. The raw data are subsampled randomly prior to summation and reconstruction to specify the desired sphere-to-background contrast ratio of the superposition image. A set of images with multiple contrast ratios is generated for visual assessment of lesion detection thresholds. To demonstrate the utility of the phantom, data were acquired with a multi-pinhole SPECT/CT scanner. Micro-liter syringes were successful in filling the small hollow spheres, and the accuracy of the dispensed volume was validated through repeated filling and weighing of the spheres. The phantom's internal rotation and the data analysis process were successful in producing the expected superposition images. Visual inspection of the multi-contrast images provided simple determination of lesion detection thresholds for this scanner (4:1 ratio for 1.5 mm spheres and 3:1 ratio for 2.0 mm spheres) at a specified cumulated background concentration (30 kBq-min microL(-1)). In summary, the micro-hollow sphere phantom demonstrated its practical utility for lesion detection evaluation and is well suited for comparing the task-based performance of small-animal SPECT and PET scanners.