SelExNet : A Self‐Supervised Physics‐Informed Framework for Multi‐Channel Joint RF and Gradient Waveform Optimization in 2D Spatially Selective Excitation
Open Access
- 14 May 2026
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (3) , 1219-1234
Abstract
Purpose To introduce SelExNet: a self-supervised framework for two-dimensional spatially selective excitation that jointly optimizes radiofrequency (RF) pulses and gradient waveforms, and extends to multi-channel transmission MRI. Methods Building on prior RF-only and joint RF-gradient optimization approaches, SelExNet couples neural RF and gradient generators with a differentiable Bloch simulator to enable self-supervised pulse optimization without requiring pre-designed target pulses. The framework jointly designs RF pulses and parameterized variable-density spiral gradient waveforms for both single- and multi-channel transmission, with patient-specific adaptation using measured, previously unseen and maps. Results Joint optimization of RF and gradients improved excitation fidelity compared to RF-only optimization. In phantom experiments with synthetic field maps, pretrained pulses showed distortions, whereas fine-tuned pulses restored geometry and uniformity. In vivo studies demonstrated anatomically precise excitation, with fine-tuning improving sharpness and reducing off-target signal. Conclusion The proposed framework enables joint RF-gradient design and extends self-supervised pulse optimization to multi-channel transmission MRI. SelExNet achieves high-fidelity, anatomically precise excitation and demonstrates robustness to field inhomogeneities, offering a scalable pathway for ultra-high field imaging.
Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (RGPIN‐2023‐03410)
- Natural Sciences and Engineering Research Council of Canada (RGPIN‐2023‐04408)
- Canadian Institutes of Health Research (PJT‐186038)
This publication has 48 references indexed in Scilit:
- Comparison of Reduced and Full Field of View in Diffusion‐Weighted MRI on Image Quality: A Meta‐AnalysisJournal of Magnetic Resonance Imaging, 2024
- Image formation in diffusion MRI: A review of recent technical developmentsJournal of Magnetic Resonance Imaging, 2017
- Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channelsMagnetic Resonance in Medicine, 2008
- Reduction of transmitter B1 inhomogeneity with transmit SENSE slice‐select pulsesMagnetic Resonance in Medicine, 2007
- Spatial domain method for the design of RF pulses in multicoil parallel excitationMagnetic Resonance in Medicine, 2006
- Transmit SENSEMagnetic Resonance in Medicine, 2002
- Compensation of multi‐dimensional selective excitation pulses using measured k‐space trajectoriesMagnetic Resonance in Medicine, 1995
- A three‐dimensional spin‐echo or inversion pulseMagnetic Resonance in Medicine, 1993
- Spectroscopic imaging with multidimensional pulses for excitation: SIMPLEMagnetic Resonance in Medicine, 1991
- Simultaneous spatial and spectral selective excitationMagnetic Resonance in Medicine, 1990