JRJason Rock
Jason Rock
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jason Rock has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jamie Near
Department of Medical Biophysics University of Toronto Toronto Ontario Canada
1 shared publication - Mark Chiew
Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
1 shared publication - Simon J. Graham
Institute of Medical Science, Temerty Faculty of Medicine, University of Toronto, 6 Queen's Park Crescent, Toronto, ON M5S 3H2, Canada; Physical Sciences Platform, Sunnybrook Research Institute, 2075 Bayview Avenue, Toronto, ON M4N 3M5, Canada; Department of Medical Biophysics, Temerty Faculty of Medicine, University of Toronto, 101 College Street, Toronto, ON M5G 2C4, Canada
1 shared publication - Yuliang Xiao
Physical Sciences Platform Sunnybrook Research Institute Toronto Ontario Canada
1 shared publication - Zhe Wu
Siemens Healthcare Limited Oakville Ontario Canada
1 shared publication
Latest Publications
- Open Access
- 14 May 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (3) , 1219-1234
SelExNet : A Self‐Supervised Physics‐Informed Framework for Multi‐Channel Joint RF and Gradient Waveform Optimization in 2D Spatially Selective Excitation
Purpose To introduce SelExNet: a self-supervised framework for two-dimensional spatially selective excitation that jointly optimizes radiofrequency (RF) pulses and gradient waveforms, and extends to multi-channel transmission MRI. Methods Building on prior RF-only and joint RF-gradient optimization approaches, SelExNet couples neural RF and gradient generators with a differentiable Bloch simulator to enable self-supervised pulse optimization without requiring pre-designed target pulses. The framework jointly designs RF pulses and parameterized variable-density spiral gradient waveforms for both single- and multi-channel transmission, with patient-specific adaptation using measured, previously unseen and maps. Results Joint optimization of RF and gradients improved excitation fidelity compared to RF-only optimization. In phantom experiments with synthetic field maps, pretrained pulses showed distortions, whereas fine-tuned pulses restored geometry and uniformity. In vivo studies demonstrated anatomically precise excitation, with fine-tuning improving sharpness and reducing off-target signal. Conclusion The proposed framework enables joint RF-gradient design and extends self-supervised pulse optimization to multi-channel transmission MRI. SelExNet achieves high-fidelity, anatomically precise excitation and demonstrates robustness to field inhomogeneities, offering a scalable pathway for ultra-high field imaging.- 14 May 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (3) , 1219-1234
Open AccessSelExNet : A Self‐Supervised Physics‐Informed Framework for Multi‐Channel Joint RF and Gradient Waveform Optimization in 2D Spatially Selective Excitation
Purpose To introduce SelExNet: a self-supervised framework for two-dimensional spatially selective excitation that jointly optimizes radiofrequency (RF) pulses and gradient waveforms, and extends to multi-channel transmission MRI. Methods Building on prior RF-only and joint RF-gradient optimization approaches, SelExNet couples neural RF and gradient generators with a differentiable Bloch simulator to enable self-supervised pulse optimization without requiring pre-designed target pulses. The framework jointly designs RF pulses and parameterized variable-density spiral gradient waveforms for both single- and multi-channel transmission, with patient-specific adaptation using measured, previously unseen and maps. Results Joint optimization of RF and gradients improved excitation fidelity compared to RF-only optimization. In phantom experiments with synthetic field maps, pretrained pulses showed distortions, whereas fine-tuned pulses restored geometry and uniformity. In vivo studies demonstrated anatomically precise excitation, with fine-tuning improving sharpness and reducing off-target signal. Conclusion The proposed framework enables joint RF-gradient design and extends self-supervised pulse optimization to multi-channel transmission MRI. SelExNet achieves high-fidelity, anatomically precise excitation and demonstrates robustness to field inhomogeneities, offering a scalable pathway for ultra-high field imaging.