Pseudocontinuous arterial spin labeling with prospective motion correction (PCASL-PROMO)
Authors:
Open Access
- 14 November 2013
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (4) , 1049-1056
Abstract
Purpose Arterial spin labeling (ASL) perfusion imaging with a segmented three‐dimensional (3D) readout is becoming increasing popular, yet conventional motion correction approaches cannot be applied in segmented imaging. The purpose of this study was to demonstrate the integration of 3D pseudocontinuous ASL (PCASL) and PROMO (PROspective MOtion correction) for cerebral blood flow measurements. Methods PROMO was integrated into 3D PCASL without increasing repetition time. PCASL was performed with and without PROMO in the absence of motion. The performance of PCASL‐PROMO was then evaluated with controlled motions using separate scans with and without PROMO and also with random motion using an interleaved scan where every repetition time is repeated twice, once with and once without PROMO. Results The difference in the average ASL signal of the 3D volume between conventional and PROMO implementations was negligible (<0.2%). ASL image artifacts from both controlled and random motions were removed significantly with PROMO, showing improved correlation with reference images. Multiple combinations of data acquired using the interleaved scan revealed that PROMO with real‐time motion updating alone reduces motion artifact significantly and that rescanning of corrupted segments is more critical in tagged images than control images. Conclusion This study demonstrates that PROMO is a successful approach to motion correction for PCASL cerebral blood flow imaging. Magn Reson Med 72:1049–1056, 2014.Keywords
This publication has 23 references indexed in Scilit:
- An embedded optical tracking system for motion-corrected magnetic resonance imaging at 7TMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Parallel and partial Fourier imaging with prospective motion correctionMagnetic Resonance in Medicine, 2012
- Prospective motion correction of high-resolution magnetic resonance imaging data in childrenNeuroImage, 2010
- Prospective motion correction for single‐voxel 1H MR spectroscopyMagnetic Resonance in Medicine, 2010
- PROMO: Real‐time prospective motion correction in MRI using image‐based trackingMagnetic Resonance in Medicine, 2009
- Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fieldsMagnetic Resonance in Medicine, 2008
- Arterial Spin-Labeling in Routine Clinical Practice, Part 1: Technique and ArtifactsAmerican Journal of Neuroradiology, 2008
- Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbxMagnetic Resonance Imaging, 2008
- Model‐free arterial spin labeling quantification approach for perfusion MRIMagnetic Resonance in Medicine, 2006
- Efficiency of inversion pulses for background suppressed arterial spin labelingMagnetic Resonance in Medicine, 2005