Coordinate Swapping in Standard Addition Graphs for Analytical Chemistry: A Simplified Path for Uncertainty Calculation in Linear and Nonlinear Plots
- 6 August 2014
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (17) , 8563-8567
Abstract
Uncertainty of the result from the method of standard addition is often underestimated due to neglect of the covariance between the intercept and the slope. In order to simplify the data analysis from standard addition experiments, we propose x–y coordinate swapping in conventional linear regression. Unlike the ratio of the intercept and slope, which is the result of the traditional method of standard addition, the result of the inverse standard addition is obtained directly from the intercept of the swapped calibration line. Consequently, the uncertainty evaluation becomes markedly simpler. The method is also applicable to nonlinear curves, such as the quadratic model, without incurring any additional complexity.Keywords
This publication has 23 references indexed in Scilit:
- Usefulness of Information Criteria for the Selection of Calibration CurvesAnalytical Chemistry, 2013
- Uncertainty of standard addition experiments: a novel approach to include the uncertainty associated with the standard in the model equationAccreditation and Quality Assurance, 2011
- Origin and early history of Die Methode des Eichzusatzes or The Method of Standard Addition with primary emphasis on its origin, early design, dissemination, and usage of termsAnalytical and Bioanalytical Chemistry, 2011
- Method of standard additions for arsenic measurements in water by ICP sector field mass spectrometry at accuracy comparable to isotope dilutionJournal of Analytical Atomic Spectrometry, 2010
- Systematic Comparison of Bias and Precision Data Obtained with Multiple-Point and One-Point Calibration in Six Validated Multianalyte Assays for Quantification of Drugs in Human PlasmaAnalytical Chemistry, 2007
- Improved calibration strategy for measurement of trace elements in biological and clinical whole blood reference materials via collision-cell inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2005
- Simple algorithms for nonlinear calibration by the classical and standard additions methodsThe Analyst, 2005
- Estimates of Precision in a Standard Additions AnalysisJournal of Chemical Education, 1999
- A systematic approach to standard addition methods in instrumental analysisJournal of Chemical Education, 1980
- Chemische Analysen mit dem Polarographen1937