Multidetector CT Angiography in Evaluation of Prosthetic Heart Valve Dysfunction
Authors:
- Jesse HabetsJHJesse Habets
- Willem P. T. M. MaliWMWillem P. T. M. Mali
- Ricardo P. J. BuddeRBRicardo P. J. Budde
- 1 November 2012
- journal article
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 32 (7) , 1893-1905
Abstract
Prosthetic heart valves (PHVs) are commonly implanted to replace diseased native heart valves. PHV dysfunction is an infrequent but potentially life-threatening condition. In daily clinical practice, transthoracic and transesophageal echocardiography and fluoroscopy are the imaging modalities used for diagnostic evaluation of suspected PHV dysfunction. These modalities may not allow determination of the cause of PHV dysfunction, mostly because of acoustic shadowing. Multidetector computed tomographic (CT) angiography is a promising complementary technique for evaluation of PHVs, especially in patients with PHV obstruction and endocarditis. The CT image quality of PHVs mainly depends on their composition, with most causing only limited artifacts. Retrospectively electrocardiographically gated acquisition is advisable for PHV imaging because it enables dynamic leaflet evaluation and anatomic assessment in both systole and diastole. For accurate image interpretation, dedicated reconstruction in plane with and perpendicular to the PHV leaflets is mandatory. Besides PHV assessment, CT also provides information on the coronary arteries, the location and patency of bypass grafts, the dimensions of the aorta, and the distance between the sternum and right ventricle, information valuable for planning repeat surgery. To achieve the optimal diagnostic yield in PHV imaging, multidisciplinary cooperation between the departments of cardiology, cardiothoracic surgery, and radiology is crucial.Keywords
This publication has 18 references indexed in Scilit:
- CT attenuation measurements are valuable to discriminate pledgets used in prosthetic heart valve implantation from paravalvular leakageBritish Journal of Radiology, 2012
- Diagnostic evaluation of left-sided prosthetic heart valve dysfunctionNature Reviews Cardiology, 2011
- Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patientsEuropean Radiology, 2011
- 2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart DiseaseJACC, 2008
- The Role of ECG-Gated MDCT in the Evaluation of Aortic and Mitral Mechanical Valves: Initial ExperienceAmerican Journal of Roentgenology, 2008
- Guidelines for reporting mortality and morbidity after cardiac valve interventionsThe Journal of Thoracic and Cardiovascular Surgery, 2008
- Will heart valve tissue engineering change the world?Nature Clinical Practice Cardiovascular Medicine, 2005
- Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the Veterans Affairs randomized trialJACC, 2000
- Long-term performance of heart valve prosthesesCurrent Problems in Cardiology, 2000
- Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses.Circulation, 1994