Jesse Habets
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jesse Habets has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Ricardo P. J. Budde
Department of Radiology, Erasmus Medical Center, Rotterdam, The Netherlands
7 shared publicationsWillem P. Th. M. Mali
Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
5 shared publicationsBas A. J. M. de Mol
Department of Cardiothoracic Surgery, Academic Medical Center, Amsterdam, The Netherlands
3 shared publicationsPetr Symersky
Department of Cardiothoracic Surgery, Academic Medical Center, Amsterdam, The Netherlands
3 shared publicationsAnje M. Spijkerboer
Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
2 shared publicationsF.L. Moll
Department of Vascular Surgery, University Medical Center Utrecht, Utrecht, the Netherlands
2 shared publications
Latest Publications
- 1 September 2015
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 50 (3) , 331-340
Magnetic Resonance Imaging with a Weak Albumin Binding Contrast Agent can Reveal Additional Endoleaks in Patients with an Enlarging Aneurysm after EVAR
- 1 September 2015
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 50 (3) , 331-340
Magnetic Resonance Imaging with a Weak Albumin Binding Contrast Agent can Reveal Additional Endoleaks in Patients with an Enlarging Aneurysm after EVAR
- Open Access
- 14 February 2015
- Published by Springer Nature in European Radiology
- Vol. 25 (7) , 2125-2133
Are novel non-invasive imaging techniques needed in patients with suspected prosthetic heart valve endocarditis? A systematic review and meta-analysis
Objectives Multimodal non-invasive imaging plays a key role in establishing a diagnosis of PHV endocarditis. The objective of this study was to provide a systematic review of the literature and meta-analysis of the diagnostic accuracy of TTE, TEE, and MDCT in patients with (suspected) PHV endocarditis. Methods Studies published between 1985 and 2013 were identified via search and cross-reference of PubMed/Embase databases. Studies were included if (1) they reported on the non-invasive index tests TTE, TEE, or MDCT; (2) data was provided on PHV endocarditis as the condition of interest; and (3) imaging results were verified against either surgical inspection/autopsy or clinical follow-up reference standards, thereby enabling the extraction of 2-by-2 tables. Results Twenty articles (including 496 patients) met the inclusion criteria for PHV endocarditis. TTE, TEE, and MDCT + TEE had a pooled sensitivity/specificity for vegetations of 29/100 %; 82/95 %, and 88/94 %, respectively. The pooled sensitivity/specificity of TTE, TEE, and MDCT + TEE for periannular complications was 36/93 %, 86/98 %, and 100/94 %, respectively. Conclusions TEE showed good sensitivity and specificity for establishing a diagnosis of PHV endocarditis. Although MDCT data are limited, this review showed that MDCT in addition to TEE may improve sensitivity in detecting life-threatening periannular complications. Key Points • Multimodal imaging is an important ingredient of diagnostic workup for PHV endocarditis. • Transthoracic and transesophageal echography may miss life-threatening periannular complications. • MDCT can improve sensitivity for the detection of life-threatening periannular complications.
- 14 February 2015
- Published by Springer Nature in European Radiology
- Vol. 25 (7) , 2125-2133
Open AccessAre novel non-invasive imaging techniques needed in patients with suspected prosthetic heart valve endocarditis? A systematic review and meta-analysis
Objectives Multimodal non-invasive imaging plays a key role in establishing a diagnosis of PHV endocarditis. The objective of this study was to provide a systematic review of the literature and meta-analysis of the diagnostic accuracy of TTE, TEE, and MDCT in patients with (suspected) PHV endocarditis. Methods Studies published between 1985 and 2013 were identified via search and cross-reference of PubMed/Embase databases. Studies were included if (1) they reported on the non-invasive index tests TTE, TEE, or MDCT; (2) data was provided on PHV endocarditis as the condition of interest; and (3) imaging results were verified against either surgical inspection/autopsy or clinical follow-up reference standards, thereby enabling the extraction of 2-by-2 tables. Results Twenty articles (including 496 patients) met the inclusion criteria for PHV endocarditis. TTE, TEE, and MDCT + TEE had a pooled sensitivity/specificity for vegetations of 29/100 %; 82/95 %, and 88/94 %, respectively. The pooled sensitivity/specificity of TTE, TEE, and MDCT + TEE for periannular complications was 36/93 %, 86/98 %, and 100/94 %, respectively. Conclusions TEE showed good sensitivity and specificity for establishing a diagnosis of PHV endocarditis. Although MDCT data are limited, this review showed that MDCT in addition to TEE may improve sensitivity in detecting life-threatening periannular complications. Key Points • Multimodal imaging is an important ingredient of diagnostic workup for PHV endocarditis. • Transthoracic and transesophageal echography may miss life-threatening periannular complications. • MDCT can improve sensitivity for the detection of life-threatening periannular complications.
- Open Access
- 26 October 2014
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 16 (3) , 343
Loeffler's endocarditis
A 73-year-old woman was admitted on the ICU with acute respiratory failure. Acute dyspnoea started several hours before presentation. Physical examination revealed a murmured, dyspnoeic patient with expiratory wheezing and peripheral oedema. Laboratory test showed very high BNP levels (2588 ng/L), decreased renal function (GFR 43 mL/min), serum creatinine (109 µmol), and a slightly increased C-reactive protein (44 mg/L). Her cardiac enzyme levels were within normal limits. Transthoracic echocardiography was performed and showed a reduced left ventricular systolic function, with apical akinesia and suspicion of an apical left ventricular thrombus (see Supplementary data online, Video S1 and Panel A). SonoVue confirmed this suspicion (see Supplementary data online, Video S2 and Panel B).
- 26 October 2014
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 16 (3) , 343
Open AccessLoeffler's endocarditis
A 73-year-old woman was admitted on the ICU with acute respiratory failure. Acute dyspnoea started several hours before presentation. Physical examination revealed a murmured, dyspnoeic patient with expiratory wheezing and peripheral oedema. Laboratory test showed very high BNP levels (2588 ng/L), decreased renal function (GFR 43 mL/min), serum creatinine (109 µmol), and a slightly increased C-reactive protein (44 mg/L). Her cardiac enzyme levels were within normal limits. Transthoracic echocardiography was performed and showed a reduced left ventricular systolic function, with apical akinesia and suspicion of an apical left ventricular thrombus (see Supplementary data online, Video S1 and Panel A). SonoVue confirmed this suspicion (see Supplementary data online, Video S2 and Panel B).
- 21 May 2014
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 30 (6) , 1201-1202
A contained rupture of the anterior wall of the myocard
- 21 May 2014
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 30 (6) , 1201-1202
A contained rupture of the anterior wall of the myocard
- 1 November 2012
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 32 (7) , 1893-1905
Multidetector CT Angiography in Evaluation of Prosthetic Heart Valve Dysfunction
Prosthetic heart valves (PHVs) are commonly implanted to replace diseased native heart valves. PHV dysfunction is an infrequent but potentially life-threatening condition. In daily clinical practice, transthoracic and transesophageal echocardiography and fluoroscopy are the imaging modalities used for diagnostic evaluation of suspected PHV dysfunction. These modalities may not allow determination of the cause of PHV dysfunction, mostly because of acoustic shadowing. Multidetector computed tomographic (CT) angiography is a promising complementary technique for evaluation of PHVs, especially in patients with PHV obstruction and endocarditis. The CT image quality of PHVs mainly depends on their composition, with most causing only limited artifacts. Retrospectively electrocardiographically gated acquisition is advisable for PHV imaging because it enables dynamic leaflet evaluation and anatomic assessment in both systole and diastole. For accurate image interpretation, dedicated reconstruction in plane with and perpendicular to the PHV leaflets is mandatory. Besides PHV assessment, CT also provides information on the coronary arteries, the location and patency of bypass grafts, the dimensions of the aorta, and the distance between the sternum and right ventricle, information valuable for planning repeat surgery. To achieve the optimal diagnostic yield in PHV imaging, multidisciplinary cooperation between the departments of cardiology, cardiothoracic surgery, and radiology is crucial.
- 1 November 2012
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 32 (7) , 1893-1905
Multidetector CT Angiography in Evaluation of Prosthetic Heart Valve Dysfunction
Prosthetic heart valves (PHVs) are commonly implanted to replace diseased native heart valves. PHV dysfunction is an infrequent but potentially life-threatening condition. In daily clinical practice, transthoracic and transesophageal echocardiography and fluoroscopy are the imaging modalities used for diagnostic evaluation of suspected PHV dysfunction. These modalities may not allow determination of the cause of PHV dysfunction, mostly because of acoustic shadowing. Multidetector computed tomographic (CT) angiography is a promising complementary technique for evaluation of PHVs, especially in patients with PHV obstruction and endocarditis. The CT image quality of PHVs mainly depends on their composition, with most causing only limited artifacts. Retrospectively electrocardiographically gated acquisition is advisable for PHV imaging because it enables dynamic leaflet evaluation and anatomic assessment in both systole and diastole. For accurate image interpretation, dedicated reconstruction in plane with and perpendicular to the PHV leaflets is mandatory. Besides PHV assessment, CT also provides information on the coronary arteries, the location and patency of bypass grafts, the dimensions of the aorta, and the distance between the sternum and right ventricle, information valuable for planning repeat surgery. To achieve the optimal diagnostic yield in PHV imaging, multidisciplinary cooperation between the departments of cardiology, cardiothoracic surgery, and radiology is crucial.
- 1 November 2012
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 32 (7) , 1907-1908
Authors’ Response
- 1 November 2012
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 32 (7) , 1907-1908
Authors’ Response
- 1 September 2012
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 5 (9) , 956-961
Imaging of Prosthetic Heart Valve Dysfunction
- 1 September 2012
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 5 (9) , 956-961
Imaging of Prosthetic Heart Valve Dysfunction
- 1 September 2012
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 85 (1017) , e616-e621
CT attenuation measurements are valuable to discriminate pledgets used in prosthetic heart valve implantation from paravalvular leakage
Sutures with polytetrafluorethylene (PTFE) felt pledgets are commonly used in prosthetic heart valve (PHV) implantation. Paravalvular leakage can be difficult to distinguish from PTFE felt pledgets on multislice CT because both present as hyperdense structures. We assessed whether pledgets can be discriminated from contrast-enhanced solutions (blood/saline) on CT images based on attenuation difference in an ex vivo experiment and under in vivo conditions. PTFE felt pledgets were sutured to the suture ring of a mechanical PHV and porcine aortic annulus, and immersed and scanned in four different contrast-enhanced (Ultravist®; 300 mg jopromide ml(-1)) saline concentrations (10.0, 12.0, 13.6 and 15.0 mg ml(-1)). Scanning was performed on a 256-slice scanner with eight different scan protocols with various tube voltage (100 kV, 120 kV) and tube current (400 mAs, 600 mAs, 800 mAs, 1000 mAs) settings. Attenuation of the pledgets and surrounding contrast-enhanced saline were measured. Additionally, the attenuation of pledgets and contrast-enhanced blood was measured on electrocardiography (ECG)-gated CTA scans of 19 patients with 22 PHVs. Ex vivo CT attenuation differences between the pledgets and contrast-enhanced solutions were larger by using higher tube voltages. CT attenuation values of the pledgets were higher than contrast-enhanced blood in patients: 420±26 Hounsfield units (mean±SD, range 383-494) and 288±41 Hounsfield units (range 202-367), respectively. PTFE felt pledgets have consistently higher attenuation than surrounding contrast-enhanced blood. CT attenuation measurements therefore may help to differentiate pledgets from paravalvular leakage, and detect paravalvular leakage in patients with suspected PHV dysfunction.
- 1 September 2012
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 85 (1017) , e616-e621
CT attenuation measurements are valuable to discriminate pledgets used in prosthetic heart valve implantation from paravalvular leakage
Sutures with polytetrafluorethylene (PTFE) felt pledgets are commonly used in prosthetic heart valve (PHV) implantation. Paravalvular leakage can be difficult to distinguish from PTFE felt pledgets on multislice CT because both present as hyperdense structures. We assessed whether pledgets can be discriminated from contrast-enhanced solutions (blood/saline) on CT images based on attenuation difference in an ex vivo experiment and under in vivo conditions. PTFE felt pledgets were sutured to the suture ring of a mechanical PHV and porcine aortic annulus, and immersed and scanned in four different contrast-enhanced (Ultravist®; 300 mg jopromide ml(-1)) saline concentrations (10.0, 12.0, 13.6 and 15.0 mg ml(-1)). Scanning was performed on a 256-slice scanner with eight different scan protocols with various tube voltage (100 kV, 120 kV) and tube current (400 mAs, 600 mAs, 800 mAs, 1000 mAs) settings. Attenuation of the pledgets and surrounding contrast-enhanced saline were measured. Additionally, the attenuation of pledgets and contrast-enhanced blood was measured on electrocardiography (ECG)-gated CTA scans of 19 patients with 22 PHVs. Ex vivo CT attenuation differences between the pledgets and contrast-enhanced solutions were larger by using higher tube voltages. CT attenuation values of the pledgets were higher than contrast-enhanced blood in patients: 420±26 Hounsfield units (mean±SD, range 383-494) and 288±41 Hounsfield units (range 202-367), respectively. PTFE felt pledgets have consistently higher attenuation than surrounding contrast-enhanced blood. CT attenuation measurements therefore may help to differentiate pledgets from paravalvular leakage, and detect paravalvular leakage in patients with suspected PHV dysfunction.
- Open Access
- 5 April 2012
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 28 (8) , 2099-2108
Artifact reduction strategies for prosthetic heart valve CT imaging
Multislice CT evaluation of prosthetic heart valves (PHV) is limited by PHV-related artifacts. We assessed the influence of different kV settings, a metal artifact reduction filter (MARF) and an iterative reconstruction algorithm (IR) on PHV-induced artifacts in an in vitro model. A Medtronic-Hall tilting disc and St Jude bileafet PHV were imaged using a 64-slice scanner with 100 kV/165 mAs, 120 kV/100 mAs, 140 kV/67 mAs at an equal CTDIvol. Images were reconstructed with (1) filtered back projection (FBP), (2) IR, (3) MARF and (4) MARF and IR. Hypo- and hyperdense artifacts volumes (mean mm3 ± SD) were quantified with 2 thresholds (≤−50 and ≥175 Hounsfield Units). Image noise was measured and the presence of secondary artifacts was scored by 2 observers independently. Mean hypodense artifacts for the Medtronic-Hall/St Jude valve (FBP) were 966 ± 23/1,738 ± 21 at 100 kV, 610 ± 13/991 ± 12 at 120 kV, and 420 ± 9/634 ± 9 at 140 kV. Compared to FBP, hypodense artifact reductions for IR were 9/8 %, 10/7 % and 12/6 % respectively, for MARF 92 %/84 %, 89/81 % and 86/77 % respectively; for MARF + IR 94/85 %, 92/82 %, and 90/79 % respectively. Mean hyperdense artifacts for the Medtronic-Hall/St Jude valve were 5,530 ± 48/6,940 ± 70 at 100 kV, 5,120 ± 42/6,250 ± 53 at 120 kV, and 5,011 ± 52/6,000 ± 0 at 140 kV. Reductions for IR were 2/2 %, 2/3 % and 3/4 % respectively, for MARF were 9/30 %, 0/25 %, 5/22 % respectively, MARF + IR 12/32 %, 4/27 % and 7/25 % respectively. Secondary artifacts were found in all MARF images. Image noise was reduced in the IR images. In vitro PHV-related artifacts can be reduced by increasing kV despite maintaining identical CTDIvol. Although MARF is more effective than IR, it induces secondary artifacts.
- 5 April 2012
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 28 (8) , 2099-2108
Open AccessArtifact reduction strategies for prosthetic heart valve CT imaging
Multislice CT evaluation of prosthetic heart valves (PHV) is limited by PHV-related artifacts. We assessed the influence of different kV settings, a metal artifact reduction filter (MARF) and an iterative reconstruction algorithm (IR) on PHV-induced artifacts in an in vitro model. A Medtronic-Hall tilting disc and St Jude bileafet PHV were imaged using a 64-slice scanner with 100 kV/165 mAs, 120 kV/100 mAs, 140 kV/67 mAs at an equal CTDIvol. Images were reconstructed with (1) filtered back projection (FBP), (2) IR, (3) MARF and (4) MARF and IR. Hypo- and hyperdense artifacts volumes (mean mm3 ± SD) were quantified with 2 thresholds (≤−50 and ≥175 Hounsfield Units). Image noise was measured and the presence of secondary artifacts was scored by 2 observers independently. Mean hypodense artifacts for the Medtronic-Hall/St Jude valve (FBP) were 966 ± 23/1,738 ± 21 at 100 kV, 610 ± 13/991 ± 12 at 120 kV, and 420 ± 9/634 ± 9 at 140 kV. Compared to FBP, hypodense artifact reductions for IR were 9/8 %, 10/7 % and 12/6 % respectively, for MARF 92 %/84 %, 89/81 % and 86/77 % respectively; for MARF + IR 94/85 %, 92/82 %, and 90/79 % respectively. Mean hyperdense artifacts for the Medtronic-Hall/St Jude valve were 5,530 ± 48/6,940 ± 70 at 100 kV, 5,120 ± 42/6,250 ± 53 at 120 kV, and 5,011 ± 52/6,000 ± 0 at 140 kV. Reductions for IR were 2/2 %, 2/3 % and 3/4 % respectively, for MARF were 9/30 %, 0/25 %, 5/22 % respectively, MARF + IR 12/32 %, 4/27 % and 7/25 % respectively. Secondary artifacts were found in all MARF images. Image noise was reduced in the IR images. In vitro PHV-related artifacts can be reduced by increasing kV despite maintaining identical CTDIvol. Although MARF is more effective than IR, it induces secondary artifacts.