Contrast-Enhanced Time-Resolved MRA for Follow-Up of Intracranial Aneurysms Treated with the Pipeline Embolization Device
Open Access
- 3 July 2014
- journal article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 35 (11) , 2112-2118
Abstract
Endovascular reconstruction and flow diversion by using the Pipeline Embolization Device is an effective treatment for complex cerebral aneurysms. Accurate noninvasive alternatives to DSA for follow-up after Pipeline Embolization Device treatment are desirable. This study evaluated the accuracy of contrast-enhanced time-resolved MRA for this purpose, hypothesizing that contrast-enhanced time-resolved MRA will be comparable with DSA and superior to 3D-TOF MRA. During a 24-month period, 37 Pipeline Embolization Device-treated intracranial aneurysms in 26 patients underwent initial follow-up by using 3D-TOF MRA, contrast-enhanced time-resolved MRA, and DSA. MRA was performed on a 1.5T unit by using 3D-TOF and time-resolved imaging of contrast kinetics. All patients underwent DSA a median of 0 days (range, 0-68) after MRA. Studies were evaluated for aneurysm occlusion, quality of visualization of the reconstructed artery, and measurable luminal diameter of the Pipeline Embolization Device, with DSA used as the reference standard. The sensitivity, specificity, and positive and negative predictive values of contrast-enhanced time-resolved MRA relative to DSA for posttreatment aneurysm occlusion were 96%, 85%, 92%, and 92%. Contrast-enhanced time-resolved MRA demonstrated superior quality of visualization (P = .0001) and a higher measurable luminal diameter (P = .0001) of the reconstructed artery compared with 3D-TOF MRA but no significant difference compared with DSA. Contrast-enhanced time-resolved MRA underestimated the luminal diameter of the reconstructed artery by 0.965 ± 0.497 mm (27% ± 13%) relative to DSA. Contrast-enhanced time-resolved MRA is a reliable noninvasive method for monitoring intracranial aneurysms following flow diversion and vessel reconstruction by using the Pipeline Embolization Device.Keywords
This publication has 19 references indexed in Scilit:
- Applications of Time-Resolved MR AngiographyAmerican Journal of Roentgenology, 2011
- Time-Resolved 3D Contrast-Enhanced MRA on 3.0T: a Non-Invasive Follow-Up Technique after Stent-Assisted Coil Embolization of the Intracranial AneurysmKorean Journal of Radiology, 2011
- Carotid Artery Stents: In Vitro Comparison of Different Stent Designs and Sizes Using CT Angiography and Contrast-Enhanced MR Angiography at 1.5T and 3TAmerican Journal of Neuroradiology, 2009
- Cranial Dural Arteriovenous Fistula: Diagnosis and Classification with Time-Resolved MR Angiography at 3TAmerican Journal of Neuroradiology, 2009
- Risk of recurrent subarachnoid haemorrhage, death, or dependence and standardised mortality ratios after clipping or coiling of an intracranial aneurysm in the International Subarachnoid Aneurysm Trial (ISAT): long-term follow-upThe Lancet Neurology, 2009
- A Second-Generation, Endoluminal, Flow-Disrupting Device for Treatment of Saccular AneurysmsAmerican Journal of Neuroradiology, 2009
- Quantification and Detectability of In-Stent Stenosis with CT Angiography and MR Angiography in Arterial Stents In VitroAmerican Journal of Roentgenology, 2007
- Noninvasive Imaging of Treated Cerebral Aneurysms, Part I: MR Angiographic Follow-Up of Coiled AneurysmsAmerican Journal of Neuroradiology, 2007
- 3.0 T vs. 1.5 T MR angiography: In vitro comparison of intravascular stent artifactsJournal of Magnetic Resonance Imaging, 2005
- Quantitative evaluation of susceptibility and shielding effects of nitinol, platinum, cobalt‐alloy, and stainless steel stentsMagnetic Resonance in Medicine, 2003