Generation of fluoroscopic 3D images with a respiratory motion model based on an external surrogate signal
Authors:
- Christopher L WilliamsCWChristopher L Williams
- Pankaj MishraPMPankaj Mishra
- Joerg RottmannJRJoerg Rottmann
- Salam DhouSDSalam Dhou
- Matthew WagarMWMatthew Wagar
- Edward G MannarinoEMEdward G Mannarino
- Raymond H MakRMRaymond H Mak
- John H LewisJLJohn H Lewis
- 30 December 2014
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (2) , 521-535
Abstract
Respiratory motion during radiotherapy can cause uncertainties in definition of the target volume and in estimation of the dose delivered to the target and healthy tissue. In this paper, we generate volumetric images of the internal patient anatomy during treatment using only the motion of a surrogate signal. Pre-treatment four-dimensional CT imaging is used to create a patient-specific model correlating internal respiratory motion with the trajectory of an external surrogate placed on the chest. The performance of this model is assessed with digital and physical phantoms reproducing measured irregular patient breathing patterns. Ten patient breathing patterns are incorporated in a digital phantom. For each patient breathing pattern, the model is used to generate images over the course of thirty seconds. The tumor position predicted by the model is compared to ground truth information from the digital phantom. Over the ten patient breathing patterns, the average absolute error in the tumor centroid position predicted by the motion model is 1.4 mm. The corresponding error for one patient breathing pattern implemented in an anthropomorphic physical phantom was 0.6 mm. The global voxel intensity error was used to compare the full image to the ground truth and demonstrates good agreement between predicted and true images. The model also generates accurate predictions for breathing patterns with irregular phases or amplitudes.Keywords
This publication has 28 references indexed in Scilit:
- A novel CT acquisition and analysis technique for breathing motion modelingPhysics in Medicine & Biology, 2013
- Use of a realistic breathing lung phantom to evaluate dose delivery errorsa)Medical Physics, 2010
- Effects of breathing variation on gating window internal target volume in respiratory gated radiation therapya)Medical Physics, 2010
- Real‐time volumetric image reconstruction and 3D tumor localization based on a single x‐ray projection image for lung cancer radiotherapyMedical Physics, 2010
- Implementation and evaluation of various demons deformable image registration algorithms on a GPUPhysics in Medicine & Biology, 2009
- The effect of respiratory motion variability and tumor size on the accuracy of average intensity projection from four‐dimensional computed tomography: An investigation based on dynamic MRIMedical Physics, 2008
- Derivation of the tumor position from external respiratory surrogates with periodical updating of the internal/external correlationPhysics in Medicine & Biology, 2007
- The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)Medical Physics, 2006
- Novel breathing motion model for radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Residual motion of lung tumours in gated radiotherapy with external respiratory surrogatesPhysics in Medicine & Biology, 2005