A prospective gating method to acquire a diverse set of free-breathing CT images for model-based 4DCT
- 1 February 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (4) , 04NT03
Abstract
Breathing motion modeling requires observation of tissues at sufficiently distinct respiratory states for proper 4D characterization. This work proposes a method to improve sampling of the breathing cycle with limited imaging dose. We designed and tested a prospective free-breathing acquisition protocol with a simulation using datasets from five patients imaged with a model-based 4DCT technique. Each dataset contained 25 free-breathing fast helical CT scans with simultaneous breathing surrogate measurements. Tissue displacements were measured using deformable image registration. A correspondence model related tissue displacement to the surrogate. Model residual was computed by comparing predicted displacements to image registration results. To determine a stopping criteria for the prospective protocol, i.e. when the breathing cycle had been sufficiently sampled, subsets of N scans where 5 ⩽ N ⩽ 9 were used to fit reduced models for each patient. A previously published metric was employed to describe the phase coverage, or ‘spread’, of the respiratory trajectories of each subset. Minimum phase coverage necessary to achieve mean model residual within 0.5 mm of the full 25-scan model was determined and used as the stopping criteria. Using the patient breathing traces, a prospective acquisition protocol was simulated. In all patients, phase coverage greater than the threshold necessary for model accuracy within 0.5 mm of the 25 scan model was achieved in six or fewer scans. The prospectively selected respiratory trajectories ranked in the (97.5 ± 4.2)th percentile among subsets of the originally sampled scans on average. Simulation results suggest that the proposed prospective method provides an effective means to sample the breathing cycle with limited free-breathing scans. One application of the method is to reduce the imaging dose of a previously published model-based 4DCT protocol to 25% of its original value while achieving mean model residual within 0.5 mm.Keywords
Funding Information
- Siemens Healthcare
This publication has 34 references indexed in Scilit:
- Use of 4-Dimensional Computed Tomography-Based Ventilation Imaging to Correlate Lung Dose and Function With Clinical OutcomesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Effective and organ doses using helical 4DCT for thoracic and abdominal therapiesJournal of Radiation Research, 2013
- Respiratory motion models: A reviewMedical Image Analysis, 2013
- Low-dose CT of the lung: potential value of iterative reconstructionsEuropean Radiology, 2012
- On a PCA-based lung motion modelPhysics in Medicine & Biology, 2011
- Investigation of four-dimensional computed tomography-based pulmonary ventilation imaging in patients with emphysematous lung regionsPhysics in Medicine & Biology, 2011
- Real-time profiling of respiratory motion: baseline drift, frequency variation and fundamental pattern changePhysics in Medicine & Biology, 2009
- Retrospective Analysis of Artifacts in Four-Dimensional CT Images of 50 Abdominal and Thoracic Radiotherapy PatientsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Inference of hysteretic respiratory tumor motion from external surrogates: a state augmentation approachPhysics in Medicine & Biology, 2008
- Dynamic ventilation imaging from four-dimensional computed tomographyPhysics in Medicine & Biology, 2006