DODylan O'COnnell

Dylan O'COnnell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dylan O'COnnell has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Retrospective Analysis of the First Clinical 5DCT Workflow

    by Michael Lauria, Minji Kim, Dylan O’connell, Yi Lao, Claudia R. Miller, Louise Naumann, Peter Boyle, Ann Raldow, Alan Lee, Ricky R. Savjani, et al.

    Background/Objectives: 5DCT was first proposed in 2005 as a motion-compensated CT simulation approach for radiotherapy treatment planning to avoid sorting artifacts that arise in 4DCT when patients breathe irregularly. Since March 2019, 5DCT has been clinically implemented for routine use at our institution to leverage this technological advantage. The clinical workflow includes a quality assurance report that describes the output of primary workflow steps. This study reports on the challenges and quality of the clinical 5DCT workflow using these quality assurance reports. Methods: We evaluated all thoracic 5DCT simulation datasets consecutively acquired at our institution between March 2019 and December 2022 for thoracic radiotherapy treatment planning. The 5DCT datasets utilized motion models constructed from 25 fast-helical free-breathing computed tomography (FHFBCTs) with simultaneous respiratory bellows signal monitoring to reconstruct individual, user-specified breathing-phase images (termed 5DCT phase images) for internal target volume contouring. Each 5DCT dataset was accompanied by a structured quality assurance report composed of qualitative and quantitative measures of the breathing pattern, image quality, DIR quality, model fitting accuracy, and a validation process by which the original FHFBCT scans were regenerated with the 5DCT model. Measures of breathing irregularity, image quality, and DIR quality were retrospectively categorized on a grading scale from 1 (regular breathing and accurate registration/modeling) to 4 (irregular breathing and inaccurate registration/modeling). The validation process was graded according to the same scale, and this grade was termed the suitability-for-treatment-planning (STP) grade. We correlated the graded variables to the STP grade. In addition to the quality assurance reports, we reviewed the contour sessions to determine how often 5DCT phase images were used for treatment planning and delivery. Results: There were 169 5DCT simulation datasets available from 156 patients for analysis. The STP was moderately correlated with breathing irregularity, image quality, and DIR quality (Spearman coefficients: 0.26, 0.30, and 0.50, respectively). Multiple linear regression analysis demonstrated that STP was correlated with regular breathing patterns (p = 0.008), image quality (p < 0.001), and better DIR quality (p < 0.001). 5DCT datasets were used for treatment planning in 82% of cases, while in 12% of cases, a backup image process was used. In total, 6% of image datasets were not used for treatment planning due to factors unrelated to the 5DCT workflow quality. Conclusions: The strongest association with STP was with DIR quality grades, as indicated by both Spearman and multiple linear regression analysis, implying that improvements to DIR accuracy and evaluation may be the best route for further improvement to 5DCT. The high rate of 5DCT phase image use for treatment planning showed that the workflow was reliable, and this has encouraged us to continue to develop and improve the workflow steps.


  • Feasibility of deriving a novel imaging biomarker based on patient-specific lung elasticity for characterizing the degree of COPD in lung SBRT patients

    by Katelyn Hasse, John Neylon, Yugang Min, Dylan O'COnnell, Percy Lee, Daniel A Low, Anand P Santhanam

    Objectives: Lung tissue elasticity is an effective spatial representation for Chronic Obstructive Pulmonary Disease phenotypes and pathophysiology. We investigated a novel imaging biomarker based on the voxel-by-voxel distribution of lung tissue elasticity. Our approach combines imaging and biomechanical modeling to characterize tissue elasticity. Methods: We acquired 4DCT images for 13 lung cancer patients with known COPD diagnoses based on GOLD 2017 criteria. Deformation vector fields (DVFs) from the deformable registration of end-inhalation and end-exhalation breathing phases were taken to be the ground-truth. A linear elastic biomechanical model was assembled from end-exhalation datasets with a density-guided initial elasticity distribution. The elasticity estimation was formulated as an iterative process, where the elasticity was optimized based on its ability to reconstruct the ground-truth. An imaging biomarker (denoted YM1-3) derived from the optimized elasticity distribution, was compared with th...


  • Safety‐oriented design of in‐house software for new techniques: A case study using a model‐based 4DCT protocol

    by Dylan O'Connell, David H. Thomas, John H. Lewis, Katelyn Hasse, Anand Santhanam, James M. Lamb, Minsong Cao, Stephen Tenn, Nzhde Agazaryan, Percy P. Lee, et al.

    Purpose: In‐house software is commonly employed to implement new imaging and therapy techniques before commercial solutions are available. Risk analysis methods, as detailed in the TG‐100 report of the American Association of Physicists in Medicine, provide a framework for quality management of processes but offer little guidance on software design. In this work, we examine a novel model‐based four‐dimensional computed tomography (4DCT) protocol using the TG‐100 approach and describe two additional methods for promoting safety of the associated in‐house software.Methods: To implement a previously published model‐based 4DCT protocol, in‐house software was necessary for tasks such as synchronizing a respiratory signal to computed tomography images, deformable image registration (DIR), model parameter fitting, and interfacing with a treatment planning system. A process map was generated detailing the workflow. Failure modes and effects analysis (FMEA) was performed to identify critical steps and guide quality interventions. Software system safety was addressed through writing “use cases,” narratives that characterize the behavior of the software, for all major operations to elicit safety requirements. Safety requirements were codified using the easy approach to requirements syntax (EARS) to ensure testability and eliminate ambiguity.Results: Sixty‐one failure modes were identified and assigned risk priority numbers using FMEA. Resultant quality management interventions include integration of a comprehensive reporting and logging system into the software, mandating daily and monthly equipment quality assurance procedures, and a checklist to be completed at image acquisition. Use cases and resulting safety requirements informed the design of needed in‐house software as well as a suite of tests performed during the image generation process.Conclusions: TG‐100 methods were used to construct a process‐level quality management program for a 4DCT imaging protocol. Two supplemental tools from the field of requirements engineering facilitated elicitation and codification of safety requirements that informed the design and testing of in‐house software necessary to implement the protocol. These general tools can be applied to promote safety when in‐house software is needed to bring new techniques to the clinic.


  • Comparison of lung tumor motion measured using a model-based 4DCT technique and a commercial protocol

    by Dylan O'COnnell, Narek Shaverdian, Amar U. Kishan, David H. Thomas, Tai H. Dou, John H. Lewis, James M. Lamb, Minsong Cao, Stephen Tenn, Lee P. Percy, et al.


  • Dependence of subject-specific parameters for a fast helical CT respiratory motion model on breathing rate: an animal study

    by Dylan O’COnnell, David H Thomas, James M Lamb, John H Lewis, Tai H Dou, Jered P Sieren, Melissa Saylor, Christian Hofmann, Eric A Hoffman, Percy P Lee, et al.

    To determine if the parameters relating lung tissue displacement to a breathing surrogate signal in a previously published respiratory motion model vary with the rate of breathing during image acquisition. An anesthetized pig was imaged using multiple fast helical scans to sample the breathing cycle with simultaneous surrogate monitoring. Three datasets were collected while the animal was mechanically ventilated with different respiratory rates: 12 bpm (breaths per minute), 17 bpm, and 24 bpm. Three sets of motion model parameters describing the correspondences between surrogate signals and tissue displacements were determined. The model error was calculated individually for each dataset, as well asfor pairs of parameters and surrogate signals from different experiments. The values of one model parameter, a vector field denoted α → which related tissue displacement to surrogate amplitude, determined for each experiment were compared. The mean model error of the three datasets was 1.00 ± 0.36 mm with a 95th percentile value of 1.69 mm. The mean error computed from all combinations of parameters and surrogate signals from different datasets was 1.14 ± 0.42 mm with a 95th percentile of 1.95 mm. The mean difference in α → over all pairs of experiments was 4.7% ± 5.4%, and the 95th percentile was 16.8%. The mean angle between pairs of α → was 5.0 ± 4.0 degrees, with a 95th percentile of 13.2 mm. The motion model parameters were largely unaffected by changes in the breathing rate during image acquisition. The mean error associated with mismatched sets of parameters and surrogate signals was 0.14 mm greater than the error achieved when using parameters and surrogate signals acquired with the same breathing rate, while maximum respiratory motion was 23.23 mm on average.


  • A prospective gating method to acquire a diverse set of free-breathing CT images for model-based 4DCT

    by Dylan O'Connell, Dan Ruan, David H Thomas, Tai H Dou, John H Lewis, Anand P Santhanam, Percy P Lee, Daniel A Low

    Breathing motion modeling requires observation of tissues at sufficiently distinct respiratory states for proper 4D characterization. This work proposes a method to improve sampling of the breathing cycle with limited imaging dose. We designed and tested a prospective free-breathing acquisition protocol with a simulation using datasets from five patients imaged with a model-based 4DCT technique. Each dataset contained 25 free-breathing fast helical CT scans with simultaneous breathing surrogate measurements. Tissue displacements were measured using deformable image registration. A correspondence model related tissue displacement to the surrogate. Model residual was computed by comparing predicted displacements to image registration results. To determine a stopping criteria for the prospective protocol, i.e. when the breathing cycle had been sufficiently sampled, subsets of N scans where 5 ⩽ N ⩽ 9 were used to fit reduced models for each patient. A previously published metric was employed to describe the phase coverage, or ‘spread’, of the respiratory trajectories of each subset. Minimum phase coverage necessary to achieve mean model residual within 0.5 mm of the full 25-scan model was determined and used as the stopping criteria. Using the patient breathing traces, a prospective acquisition protocol was simulated. In all patients, phase coverage greater than the threshold necessary for model accuracy within 0.5 mm of the 25 scan model was achieved in six or fewer scans. The prospectively selected respiratory trajectories ranked in the (97.5 ± 4.2)th percentile among subsets of the originally sampled scans on average. Simulation results suggest that the proposed prospective method provides an effective means to sample the breathing cycle with limited free-breathing scans. One application of the method is to reduce the imaging dose of a previously published model-based 4DCT protocol to 25% of its original value while achieving mean model residual within 0.5 mm.


  • Initial clinical observations of intra- and interfractional motion variation in MR-guided lung SBRT

    by David H Thomas, Anand Santhanam, Amar U Kishan, Minsong Cao, James Lamb, Yugang Min, Dylan O'COnnell, Yingli Yang, Nzhde Agazaryan, Percy Lee, et al.

    Objective: To evaluate variations in intra- and interfractional tumour motion, and the effect on internal target volume (ITV) contour accuracy, using deformable image registration of real-time two-dimensional-sagittal cine-mode MRI acquired during lung stereotactic body radiation therapy (SBRT) treatments. Methods: Five lung tumour patients underwent free-breathing SBRT treatments on the ViewRay system, with dose prescribed to a planning target volume (defined as a 3–6 mm expansion of the 4DCT-ITV). Sagittal slice cine-MR images (3.5 × 3.5 mm2 pixels) were acquired through the centre of the tumour at 4 frames per second throughout the treatments (3–4 fractions of 21–32 min). Tumour gross tumour volumes (GTVs) were contoured on the first frame of the MR cine and tracked for the first 20 min of each treatment using offline optical-flow based deformable registration implemented on a GPU cluster. A ground truth ITV (MR-ITV20 min) was formed by taking the union of tracked GTV contours. Pseudo-ITVs were generated from unions of the GTV contours tracked over 10 s segments of image data (MR-ITV10 s). Results: Differences were observed in the magnitude of median tumour displacement between days of treatments. MR-ITV10 s areas were as small as 46% of the MR-ITV20 min. Conclusion: An ITV offers a “snapshot” of breathing motion for the brief period of time the tumour is imaged on a specific day. Real-time MRI over prolonged periods of time and over multiple treatment fractions shows that ITV size varies. Further work is required to investigate the dosimetric effect of these results. Advances in knowledge: Five lung tumour patients underwent free-breathing MRI-guided SBRT treatments, and their tumours tracked using deformable registration of cine-mode MRI. The results indicate that variability of both intra- and interfractional breathing amplitude should be taken into account during planning of lung radiotherapy.


  • Investigating the minimum scan parameters required to generate free-breathing motion artefact-free fast-helical CT

    by David H Thomas, Jun Tan, Jack Neylon, Tai Dou, Dylan O’connell, Michael McNitt-Gray, Percy Lee, James Lamb, Daniel A Low

    A recently proposed “5DCT” protocol uses deformable registration of free-breathing fast-helical CT scans to generate a breathing motion model. In order to allow accurate registration, free-breathing images are required to be free of doubling-artefacts, which arise when tissue motion is greater than scan speed. Using a unique set of digital phantoms based on patient data and verified with a motion phantom, this work identifies the minimum scanner parameters required to successfully generate free-breathing artefact-free fast-helical scans. A motion phantom and 5 patients were imaged 25 times under free-breathing conditions in alternating directions with a 64-slice CT scanner employing a low-dose fast-helical protocol. A series of high temporal resolution (0.1 s) 5DCT scan data sets was generated in each case. A simulated CT scanner was used to “image” each free-breathing data set. Various CT scanner detector widths and rotation times were simulated, and verified using the motion phantom results. Motion-induced artefacts were quantified in patient images using structural similarity maps to determine the similarity between axial slices. Increasing amounts of motion-induced artefacts were observed with increasing rotation times >0.2 s for 16 mm detector configuration. The current generation of 16-slice CT scanners, which are present in the majority of Radiation Oncology departments, are not capable of generating free-breathing sorting artefact-free images required for 5DCT. A recently proposed “5DCT” protocol uses deformable registration of free-breathing fast-helical CT scans to generate a breathing motion model. In order to allow accurate registration, free-breathing images are required to be free of doubling-artefacts, which arise when tissue motion is greater than scan speed. The results suggest that the current generation of 16-slice CT scanners, present in the majority of Radiation Oncology departments, are not capable of generating the free-breathing images required for 5DCT.


  • Comparison of breathing gated CT images generated using a 5DCT technique and a commercial clinical protocol in a porcine model

    by Dylan P. O'COnnell, David H. Thomas, Tai H. Dou, James M. Lamb, Franklin Feingold, Daniel A. Low, Matthew K. Fuld, Jered P. Sieren, Chelsea M. Sloan, Melissa A. Shirk, et al.

    Purpose: To demonstrate that a “5DCT” technique which utilizes fast helical acquisition yields the same respiratory‐gated images as a commercial technique for regular, mechanically produced breathing cycles.Methods: Respiratory‐gated images of an anesthetized, mechanically ventilated pig were generated using a Siemens low‐pitch helical protocol and 5DCT for a range of breathing rates and amplitudes and with standard and low dose imaging protocols. 5DCT reconstructions were independently evaluated by measuring the distances between tissue positions predicted by a 5D motion model and those measured using deformable registration, as well by reconstructing the originally acquired scans. Discrepancies between the 5DCT and commercial reconstructions were measured using landmark correspondences.Results: The mean distance between model predicted tissue positions and deformably registered tissue positions over the nine datasets was 0.65 ± 0.28 mm. Reconstructions of the original scans were on average accurate to 0.78 ± 0.57 mm. Mean landmark displacement between the commercial and 5DCT images was 1.76 ± 1.25 mm while the maximum lung tissue motion over the breathing cycle had a mean value of 27.2 ± 4.6 mm. An image composed of the average of 30 deformably registered images acquired with a low dose protocol had 6 HU image noise (single standard deviation) in the heart versus 31 HU for the commercial images.Conclusions: An end to end evaluation of the 5DCT technique was conducted through landmark based comparison to breathing gated images acquired with a commercial protocol under highly regular ventilation. The techniques were found to agree to within 2 mm for most respiratory phases and most points in the lung.