Comparison of seven videolaryngoscopes with the Macintosh laryngoscope in manikins by experienced and novice personnel
- 12 March 2016
- journal article
- research article
- Published by Wiley in Anaesthesia
- Vol. 71 (5) , 556-564
Abstract
Summary: Videolaryngoscopy is often reserved for ‘anticipated’ difficult airways, but thereby can result in a higher overall rate of complications. We observed 65 anaesthetists, 67 residents in anaesthesia, 56 paramedics and 65 medical students, intubating the trachea of a standardised manikin model with a normal airway using seven devices: Macintosh classic laryngoscope, Airtraq ® , Storz C‐ MAC ® , Coopdech VLP ‐100 ® , Storz C‐ MAC D‐Blade ® , GlideScope Cobalt ® , McGrath Series5 ® and Pentax AWS ® ) in random order. Time to and proportion of successful intubation, complications and user satisfaction were compared. All groups were fastest using devices with a Macintosh‐type blade. All groups needed significantly more attempts using the Airtraq and Pentax AWS (all p < 0.05). Devices with a Macintosh‐type blade (classic laryngoscope and C‐ MAC ) scored highest in user satisfaction. Our results underline the importance of variability in device performance across individuals and staff groups, which have important implications for which devices hospital providers should rationally purchase.Keywords
This publication has 26 references indexed in Scilit:
- The myth of the difficult airway: airway management revisitedAnaesthesia, 2014
- Defining and developing expertise in tracheal intubation using a GlideScope ® for anaesthetists with expertise in Macintosh direct laryngoscopy: an in‐vivo longitudinal studyAnaesthesia, 2014
- A Mannequin Study of Intubation with the AP Advance and GlideScope Ranger Videolaryngoscopes and the Macintosh LaryngoscopeAnesthesia & Analgesia, 2011
- Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 2: intensive care and emergency departmentsBritish Journal of Anaesthesia, 2011
- A Comparison of Three Videolaryngoscopes: The Macintosh Laryngoscope Blade Reduces, but Does Not Replace, Routine Stylet Use for Intubation in Morbidly Obese PatientsAnesthesia & Analgesia, 2009
- A Macintosh Laryngoscope Blade for Videolaryngoscopy Reduces Stylet Use in Patients with Normal AirwaysAnesthesia & Analgesia, 2009
- Randomized controlled trial of intubation with the McGrath® Series 5 videolaryngoscope by inexperienced anaesthetistsBritish Journal of Anaesthesia, 2009
- The difficult airway in the emergency departmentInternational Journal of Emergency Medicine, 2008
- Evaluation of four manikins as simulators for teaching airway management procedures specified in the Difficult Airway Society guidelines, and other advanced airway skills*Anaesthesia, 2007
- Laryngoscopic IntubationAnesthesiology, 2003