Barbe Ma Pieters
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Barbe Ma Pieters has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
A. A. J. van Zundert
The University of Queensland, Faculty of Medicine and Biomedical Sciences, Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia
2 shared publicationsAndre A. van Zundert
Department of Anesthesia & Perioperative Medicine, Royal Brisbane & Women’s Hospital, The University of Queensland, Brisbane, Queensland, Australia
2 shared publicationsMaurice Theunissen
Department of Anesthesiology and Pain Management, Maastricht UMC+, Maastricht, the Netherlands
2 shared publicationsA. A. J. Van Zundert
Faculty of Medicine and Biomedical Sciences, University of Queensland and Royal Brisbane and Women's Hospital, Herston Campus, Brisbane, Queensland
1 shared publicationAndre Aj van Zundert
Department of Anaesthesia and Perioperative Medicine, The University of Queensland, Royal Brisbane and Women's Hospital, Brisbane, QLD 4029, Australia
1 shared publication- Bjorn Winkens
Department of Methodology and Statistics, Maastricht University Medical Center+, Debyelaan 25, 6229 HX Maastricht, The Netherlands
1 shared publication
Latest Publications
- 1 July 2018
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 127 (1) , 304-305
In Response
- 1 July 2018
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 127 (1) , 304-305
In Response
- 1 March 2018
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 126 (3) , 988-994
Macintosh Blade Videolaryngoscopy Combined With Rigid Bonfils Intubation Endoscope Offers a Suitable Alternative for Patients With Difficult Airways
BACKGROUND: In the armamentarium of an anesthesiologist, videolaryngoscopy is a valuable addition to secure the airway. However, when the videolaryngoscope (VLS) offers no solution, few options remain. Earlier, we presented an intubation technique combining Macintosh blade VLS and Bonfils intubation endoscope (BIE) for a patient with a history of very difficult intubation. In the present study, we evaluated this technique to establish whether it is a valuable alternative. METHODS: In this single-blinded nonrandomized study, 38 patients with a history of difficult intubation or 1 or more predictors of difficult intubation, scoring a Cormack & Lehane (C&L) grade III or IV using Macintosh blade VLS, were included. Patients were intubated combining the VLS with the BIE. The C&L grade was scored 3 times during (1) direct laryngoscopy; (2) indirect videolaryngoscopy; and (3) using the combined technique (VLS + BIE). Afterward, 2 blinded anesthesiologists assessed the C&L grade using the pictures taken during the procedure. RESULTS: Data of 38 patients were analyzed. An improvement of the C&L grade with the combined technique occurred in 33 of 38 patients (86.8%; 95% confidence interval, 71.9%–95.6%). Reviewer 1 reported an improvement of the C&L grade with the combined technique in 37 of 38 patients. Reviewer 2 reported improvement in 33 and deterioration in 2 of the patients. No complications occurred. CONCLUSIONS: The combined use of a VLS with Macintosh blade and BIE gives the anesthesiologist a valuable alternative intubation option in patients with extremely difficult airways.
- 1 March 2018
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 126 (3) , 988-994
Macintosh Blade Videolaryngoscopy Combined With Rigid Bonfils Intubation Endoscope Offers a Suitable Alternative for Patients With Difficult Airways
BACKGROUND: In the armamentarium of an anesthesiologist, videolaryngoscopy is a valuable addition to secure the airway. However, when the videolaryngoscope (VLS) offers no solution, few options remain. Earlier, we presented an intubation technique combining Macintosh blade VLS and Bonfils intubation endoscope (BIE) for a patient with a history of very difficult intubation. In the present study, we evaluated this technique to establish whether it is a valuable alternative. METHODS: In this single-blinded nonrandomized study, 38 patients with a history of difficult intubation or 1 or more predictors of difficult intubation, scoring a Cormack & Lehane (C&L) grade III or IV using Macintosh blade VLS, were included. Patients were intubated combining the VLS with the BIE. The C&L grade was scored 3 times during (1) direct laryngoscopy; (2) indirect videolaryngoscopy; and (3) using the combined technique (VLS + BIE). Afterward, 2 blinded anesthesiologists assessed the C&L grade using the pictures taken during the procedure. RESULTS: Data of 38 patients were analyzed. An improvement of the C&L grade with the combined technique occurred in 33 of 38 patients (86.8%; 95% confidence interval, 71.9%–95.6%). Reviewer 1 reported an improvement of the C&L grade with the combined technique in 37 of 38 patients. Reviewer 2 reported improvement in 33 and deterioration in 2 of the patients. No complications occurred. CONCLUSIONS: The combined use of a VLS with Macintosh blade and BIE gives the anesthesiologist a valuable alternative intubation option in patients with extremely difficult airways.
- 12 March 2016
- Published by Wiley in Anaesthesia
- Vol. 71 (5) , 556-564
Comparison of seven videolaryngoscopes with the Macintosh laryngoscope in manikins by experienced and novice personnel
Summary: Videolaryngoscopy is often reserved for ‘anticipated’ difficult airways, but thereby can result in a higher overall rate of complications. We observed 65 anaesthetists, 67 residents in anaesthesia, 56 paramedics and 65 medical students, intubating the trachea of a standardised manikin model with a normal airway using seven devices: Macintosh classic laryngoscope, Airtraq ® , Storz C‐ MAC ® , Coopdech VLP ‐100 ® , Storz C‐ MAC D‐Blade ® , GlideScope Cobalt ® , McGrath Series5 ® and Pentax AWS ® ) in random order. Time to and proportion of successful intubation, complications and user satisfaction were compared. All groups were fastest using devices with a Macintosh‐type blade. All groups needed significantly more attempts using the Airtraq and Pentax AWS (all p < 0.05). Devices with a Macintosh‐type blade (classic laryngoscope and C‐ MAC ) scored highest in user satisfaction. Our results underline the importance of variability in device performance across individuals and staff groups, which have important implications for which devices hospital providers should rationally purchase.
- 12 March 2016
- Published by Wiley in Anaesthesia
- Vol. 71 (5) , 556-564
Comparison of seven videolaryngoscopes with the Macintosh laryngoscope in manikins by experienced and novice personnel
Summary: Videolaryngoscopy is often reserved for ‘anticipated’ difficult airways, but thereby can result in a higher overall rate of complications. We observed 65 anaesthetists, 67 residents in anaesthesia, 56 paramedics and 65 medical students, intubating the trachea of a standardised manikin model with a normal airway using seven devices: Macintosh classic laryngoscope, Airtraq ® , Storz C‐ MAC ® , Coopdech VLP ‐100 ® , Storz C‐ MAC D‐Blade ® , GlideScope Cobalt ® , McGrath Series5 ® and Pentax AWS ® ) in random order. Time to and proportion of successful intubation, complications and user satisfaction were compared. All groups were fastest using devices with a Macintosh‐type blade. All groups needed significantly more attempts using the Airtraq and Pentax AWS (all p < 0.05). Devices with a Macintosh‐type blade (classic laryngoscope and C‐ MAC ) scored highest in user satisfaction. Our results underline the importance of variability in device performance across individuals and staff groups, which have important implications for which devices hospital providers should rationally purchase.
- Open Access
- 1 January 2016
- Published by Medknow in Indian Journal of Anaesthesia
- Vol. 60 (5) , 325-9
Videolaryngoscopes differ substantially in illumination of the oral cavity: A manikin study
Background and Aims: Insufficient illumination of the oral cavity during endotracheal intubation may result in suboptimal conditions. Consequently, suboptimal illumination and laryngoscopy may lead to potential unwanted trauma to soft tissues of the pharyngeal mucosa. We investigated illumination of the oral cavity by different videolaryngoscopes (VLS) in a manikin model. Methods: We measured light intensity from the mouth opening of a Laerdal intubation trainer comparing different direct and indirect VLS at three occasions, resembling optimal to less-than-optimal intubation conditions; at the photographer's dark room, in an operating theatre and outdoors in bright sunlight. Results: Substantial differences in luminance were detected between VLS. The use of LED light significantly improved light production. All VLS produced substantial higher luminance values in a well-luminated environment compared to the dark photographer's room. The experiments outside-in bright sunlight-were interfered with by direct sunlight penetration through the synthetic material of the manikin, making correct measurement of luminance in the oropharynx invalid. Conclusion: Illumination of the oral cavity differs widely among direct and indirect VLS. The clinician should be aware of the possibility of suboptimal illumination of the oral cavity and the potential risk this poses for the patient.
- 1 January 2016
- Published by Medknow in Indian Journal of Anaesthesia
- Vol. 60 (5) , 325-9
Open AccessVideolaryngoscopes differ substantially in illumination of the oral cavity: A manikin study
Background and Aims: Insufficient illumination of the oral cavity during endotracheal intubation may result in suboptimal conditions. Consequently, suboptimal illumination and laryngoscopy may lead to potential unwanted trauma to soft tissues of the pharyngeal mucosa. We investigated illumination of the oral cavity by different videolaryngoscopes (VLS) in a manikin model. Methods: We measured light intensity from the mouth opening of a Laerdal intubation trainer comparing different direct and indirect VLS at three occasions, resembling optimal to less-than-optimal intubation conditions; at the photographer's dark room, in an operating theatre and outdoors in bright sunlight. Results: Substantial differences in luminance were detected between VLS. The use of LED light significantly improved light production. All VLS produced substantial higher luminance values in a well-luminated environment compared to the dark photographer's room. The experiments outside-in bright sunlight-were interfered with by direct sunlight penetration through the synthetic material of the manikin, making correct measurement of luminance in the oropharynx invalid. Conclusion: Illumination of the oral cavity differs widely among direct and indirect VLS. The clinician should be aware of the possibility of suboptimal illumination of the oral cavity and the potential risk this poses for the patient.
- 12 August 2015
- Published by Wiley in Anaesthesia
- Vol. 70 (9) , 1094-1095
Use of the Macintosh laryngoscope for double‐lumen tracheal tube placement
- 12 August 2015
- Published by Wiley in Anaesthesia
- Vol. 70 (9) , 1094-1095
Use of the Macintosh laryngoscope for double‐lumen tracheal tube placement
- Open Access
- 1 July 2015
- Published by SAGE Publications in Anaesthesia and Intensive Care
- Vol. 43 (1_suppl) , 4-11
Pioneers of Laryngoscopy: Indirect, Direct and Video Laryngoscopy
Airway management is one of the core skills of the anaesthetist and various techniques of airway management have developed over many years. Initially, the only view of the glottis that could be obtained was an indirect view (indirect laryngoscopy). Late in the 19th century, a direct view of the glottis was obtained via various direct laryngoscopes. Currently, in the early 21st century, there has been a return to indirect laryngoscopy via videolaryngoscopy using a videolaryngoscope. The aim of this paper is to give a historical overview of the development of both direct and indirect laryngoscopy.
- 1 July 2015
- Published by SAGE Publications in Anaesthesia and Intensive Care
- Vol. 43 (1_suppl) , 4-11
Open AccessPioneers of Laryngoscopy: Indirect, Direct and Video Laryngoscopy
Airway management is one of the core skills of the anaesthetist and various techniques of airway management have developed over many years. Initially, the only view of the glottis that could be obtained was an indirect view (indirect laryngoscopy). Late in the 19th century, a direct view of the glottis was obtained via various direct laryngoscopes. Currently, in the early 21st century, there has been a return to indirect laryngoscopy via videolaryngoscopy using a videolaryngoscope. The aim of this paper is to give a historical overview of the development of both direct and indirect laryngoscopy.