Turn-on fluorescent cyanide sensor based on copper ion-modified CdTe quantum dots
- 20 October 2008
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 134 (1) , 107-113
Abstract
A new fluorescent sensor for the sensitive and selective detection of cyanide (CN−) in aqueous media was developed herein. The sensing approach is based on CN−-modulated quenching behavior of Cu2+ toward the photoluminescence (PL) of CdTe quantum dots (QDs). In the presence of CN−, the PL of QDs that have been quenched by Cu2+ was found to be efficiently recovered, which then allows the detection of CN− in a very simple approach. Experimental results showed that the pH of the buffer solution, concentration of copper ions, and size of CdTe QDs all influenced the response of the sensor to CN−. Under the optimal conditions, a good linear relationship between the PL intensity and the concentration of CN− can be obtained in the range of 3.0 × 10−7 to 1.2 × 10−5 M, with a detection limit as low as 1.5 × 10−7 M. In addition, the present fluorescent sensor possesses remarkable selectivity for cyanide over other anions, and negligible influences were observed on the cyanide detection by the coexistence of other anions or biological species (such as albumin and typical blood constituents). Therefore, we expect the proposed copper ion-modified QDs to be an efficient and reliable sensing system to monitor cyanide concentration in environmental or clinical applications.Keywords
This publication has 41 references indexed in Scilit:
- Cyanide Sensing with Organic Dyes: Studies in Solution and on Nanostructured Al2O3 SurfacesChemistry – A European Journal, 2008
- Specific Colorimetric Detection of Cyanide Triggered by a Conformational Switch in Vitamin B12Inorganic Chemistry, 2008
- Anion recognition and sensing in organic and aqueous media using luminescent and colorimetric sensorsCoordination Chemistry Reviews, 2006
- A modular approach to anion binding podands: adaptability in design and synthesis leads to adaptability in propertiesChemical Communications, 2006
- Chromogenic Anion Sensors2005
- Analytical techniques for cyanide in blood and published blood cyanide concentrations from healthy subjects and fire victimsAnalytica Chimica Acta, 2004
- Fluorogenic and Chromogenic Chemosensors and Reagents for AnionsChemical Reviews, 2003
- Anion Recognition and Sensing: The State of the Art and Future PerspectivesAngewandte Chemie International Edition, 2001
- Determination of Cyanide in Whole Blood by Capillary Gas Chromatography with Cryogenic Oven TrappingAnalytical Chemistry, 1998
- Neutral anion receptors: design and applicationChemical Communications, 1998