Dilating and fracturing side struts of open cell stents frequently used in pediatric cardiac interventions—An in vitro study
Open Access
- 8 August 2018
- journal article
- research article
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 31 (6) , 834-840
Abstract
Background: Open cell stents are frequently used in interventional therapy of congenital heart disease. Overstenting of vessel branches may necessitate strut dilation.Methods and Results: The strut size achievable in Bard Valeo and Cook Formula stents, and the pressure necessary to fracture struts was assessed. In addition, a self expanding stent (Optimed SinusflexDS) was also tested. With the original balloon at nominal pressure, in Valeo stents side struts could be dilated to approximately 90% of the nominal stent diameter, in Formula stents to approximately 80%. With larger high pressure woven balloons, strut size increased to approximately 125% in Valeo stents, and to approximately 105% in the Formula. Strut fracture can connect two adjoining struts. Pressures were dependent on the balloon utilized. Sidestruts of the Sinusflex could lastingly overdilated with large balloons only.Conclusion: Dilation and overdilation of side struts in open cell stents can be achieved. Dependent on the clinical context, the original balloon used to place the premounted stent can be used to achieve strut dilation, but woven high pressure balloons maybe safer for patients. Should a larger diameter be required, these high pressure woven balloons can achieve bigger diameters and even strut fracture.Keywords
This publication has 11 references indexed in Scilit:
- Expansion Characteristics of Stents Used in Congenital Heart Disease: Serial Dilation Offers Improved Expansion Potential Compared to Direct Dilation: Results from a Pediatric Interventional Cardiology Early Career Society (PICES) InvestigationCongenital Heart Disease, 2016
- The Valeo stent: a pre-mounted, open-cell, large stent for use in small children with CHDCardiology in the Young, 2015
- The VALEO® vascular stent for cardiovascular lesions in childrenEuroIntervention, 2015
- The Edwards Valeo lifestents in the treatment and palliation of congenital heart disease in infants and small childrenCatheterization and Cardiovascular Interventions, 2015
- Initial experience with the cook formula balloon expandable stent in congenital heart diseaseCatheterization and Cardiovascular Interventions, 2014
- Ultra-High-Pressure Balloon Angioplasty for Treatment of Resistant Stenoses Within or Adjacent to Previously Implanted Pulmonary Arterial StentsCirculation: Cardiovascular Interventions, 2009
- The efficacy and safety of stent redilatation in congenital heart diseaseHeart, 2003
- Stents: What's available to the pediatric interventional cardiologist?Catheterization and Cardiovascular Interventions, 2002
- Open‐cell design stents in congenital heart disease: A comparison of IntraStent vs. Palmaz stentsCatheterization and Cardiovascular Interventions, 2002
- Use of endovascular stents in congenital heart disease.Circulation, 1991