Fluid Reservoir Characteristics in Established Scleral Lens Wear, Part II: Evaluation of Tear Exchange and Midday Fogging
Open Access
- 2 April 2026
- journal article
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 52 (6) , 223-226
Abstract
Objectives: Tear exchange is less robust with scleral lenses compared to other modalities. This study evaluates tear exchange with scleral lens wear and examines relationships between tear exchange and optical density of the fluid reservoir and patient-reported midday fogging in established scleral lens wearers. Methods: Participants reported if they experienced midday fogging. Tear exchange was evaluated by observing sodium fluorescein uptake into the post-lens fluid reservoir after 10 seconds, and 1, 2.5, and 5 minutes. Optical density of the fluid reservoir was measured using Scheimpflug imaging. Sensitivity, specificity, and negative and positive predictive value (NPV and PPV) of tear exchange as a predictor for fogging were calculated. Results: Tear exchange occurred within 5 minutes in 64% of eyes. The difference in fluid reservoir optical density for eyes with and without tear exchange was greatest when tear exchange occurred within 10 seconds. Tear exchange between 1-5 minutes was not predictive for fogging. Tear exchange occurring within 10 seconds showed low sensitivity and NPV, but high specificity (87%) and PPV (71%) for predicting fogging. Conclusion: Tear exchange occurred in a majority of eyes in this study. Scleral lens wearers with a rapid tear exchange rate were more likely to report midday fogging.Keywords
This publication has 17 references indexed in Scilit:
- Current U.S. based optometric scleral lens curricula and fitting recommendations: SCOPE educators surveyContact Lens and Anterior Eye, 2021
- The REDCap consortium: Building an international community of software platform partnersJournal of Biomedical Informatics, 2019
- A measure of tear inflow in habitual scleral lens wearers with and without midday foggingContact Lens and Anterior Eye, 2019
- Scleral lens fitting and assessment strategiesContact Lens and Anterior Eye, 2019
- Changes in Optical Density of Postlens Fluid Reservoir During 2 Hours of Scleral Lens WearEye & Contact Lens: Science & Clinical Practice, 2018
- Silicone Hydrogel and Rigid Gas-Permeable Scleral Lens Tear ExchangeEye & Contact Lens: Science & Clinical Practice, 2018
- Complications and fitting challenges associated with scleral contact lenses: A reviewContact Lens and Anterior Eye, 2016
- Research electronic data capture (REDCap)—A metadata-driven methodology and workflow process for providing translational research informatics supportJournal of Biomedical Informatics, 2009
- Tear mixing under a soft contact lens: effects of lens diameterAmerican Journal of Ophthalmology, 1999
- Fluorophotometric Assessment of Tear Turnover Under Rigid Contact LensesCornea, 1992