Jennifer Swingle Fogt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jennifer Swingle Fogt has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Muriel M. Schornack
Mayo Clinic Department of Ophthalmology Rochester Minnesota USA
10 shared publications - Jennifer S. Harthan
Illinois College of Optometry, United States
8 shared publications - Cherie B. O.D. Nau
Mayo Clinic Minnesota, Rochester, MN 55905, USA
7 shared publications - Ellen Shorter
Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, IL 60612, USA
7 shared publications Amy Nau
Korb and Associates Boston Massachusetts USA
5 shared publicationsEllen Shorter
University of Illinois at Chicago Chicago Illinois USA
5 shared publications
Latest Publications
- 25 August 2026
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 52 (10) , 432-435
Complications of Poorly Fitted Scleral Lenses and Approaches to Continued Wear
Scleral lenses (SLs) are increasingly considered a mainstream option for optical correction in patients with corneal irregularity and for protection of the ocular surface in patients with ocular surface disease. However, there can be complications with SL if the fit and disease is not regularly monitored. This case series reviews complications from poorly fitted SLs. Changes in SL design may allow a patient to resume successful lens wear. Regardless, SL fit and underlying disease states should be assessed at regularly scheduled intervals for new concerns in all patients and for recurrence of problems despite modification of fit in those who suffer complications.
- 25 August 2026
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 52 (10) , 432-435
Complications of Poorly Fitted Scleral Lenses and Approaches to Continued Wear
Scleral lenses (SLs) are increasingly considered a mainstream option for optical correction in patients with corneal irregularity and for protection of the ocular surface in patients with ocular surface disease. However, there can be complications with SL if the fit and disease is not regularly monitored. This case series reviews complications from poorly fitted SLs. Changes in SL design may allow a patient to resume successful lens wear. Regardless, SL fit and underlying disease states should be assessed at regularly scheduled intervals for new concerns in all patients and for recurrence of problems despite modification of fit in those who suffer complications.
- Open Access
- 22 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3181
Presence of Eyelid Disease in Habitual Scleral Lens Wearers
Background/Objectives: As scleral lens (SL) use continues to expand, particularly for medically necessary management of corneal irregularity and ocular surface disease, it is important to determine if wear of these lenses is associated with eyelid disease. This study evaluated habitual SL wearers for meibomian gland obstruction, meibum quality, and signs of lid margin inflammation. Methods: Eligible participants wore scleral lenses in one or both eyes for any indication and had been wearing their current lens design(s) for at least six months, with habitual wear of ≥5 h per day, six days per week. Eyelid inflammation metrics were specifically assessed. Results: Forty-nine scleral lens wearers (32 females) were enrolled. Upper lid wiper epitheliopathy (LWE) was present in 21 eyes (43%), and lower LWE was present in 15 eyes (31%). Thirty-nine eyes (80%) had expressible meibomian glands. Eyes with no expressible meibum were significantly higher in ocular surface disease (39%, 7/18) than corneal irregularity (11%, 3/27) (p = 0.03). Lid margin telangiectasia was present in wearers with ocular surface disease (61%, 11/18) and corneal irregularity (19%, 5/26) (p = 0.005). Conclusions: Eyelid disease was common among habitual scleral wearers regardless of indication for lens use. Eyes with ocular surface disease demonstrated a higher prevalence of meibomian gland obstruction and lid margin telangiectasia compared to those with corneal irregularity.
- 22 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3181
Open AccessPresence of Eyelid Disease in Habitual Scleral Lens Wearers
Background/Objectives: As scleral lens (SL) use continues to expand, particularly for medically necessary management of corneal irregularity and ocular surface disease, it is important to determine if wear of these lenses is associated with eyelid disease. This study evaluated habitual SL wearers for meibomian gland obstruction, meibum quality, and signs of lid margin inflammation. Methods: Eligible participants wore scleral lenses in one or both eyes for any indication and had been wearing their current lens design(s) for at least six months, with habitual wear of ≥5 h per day, six days per week. Eyelid inflammation metrics were specifically assessed. Results: Forty-nine scleral lens wearers (32 females) were enrolled. Upper lid wiper epitheliopathy (LWE) was present in 21 eyes (43%), and lower LWE was present in 15 eyes (31%). Thirty-nine eyes (80%) had expressible meibomian glands. Eyes with no expressible meibum were significantly higher in ocular surface disease (39%, 7/18) than corneal irregularity (11%, 3/27) (p = 0.03). Lid margin telangiectasia was present in wearers with ocular surface disease (61%, 11/18) and corneal irregularity (19%, 5/26) (p = 0.005). Conclusions: Eyelid disease was common among habitual scleral wearers regardless of indication for lens use. Eyes with ocular surface disease demonstrated a higher prevalence of meibomian gland obstruction and lid margin telangiectasia compared to those with corneal irregularity.
- Open Access
- 14 April 2026
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 52 (6) , 217-222
Fluid Reservoir Characteristics in Established Scleral Lens Wear, Part I—Evaluation of Fluid Reservoir Depth and Midday Fogging
Objectives: Fluid reservoir (FR) depth is an important parameter in the evaluation of scleral lens fitting, yet the range of depths compatible with successful wear, clinicians' ability to estimate depth, and implications of FR depth on midday fogging have yet to be fully elucidated. This study quantified FR depth of habitual scleral lens wearers, compared clinician estimates and image-based measurements of depth, and evaluated optical density of the FR to assess the effect of FR depth on midday fogging. Methods: Habitual scleral lens wearers consented to participate at three sites. FR depth was estimated using slitlamp evaluation by experienced examiners. Measurements of the depth and optical density of the FR were collected using Scheimpflug images. Results: The mean estimated (265±97; range: 0–500 µm) and image-derived (264±111; range: 40–555 µm) FR depths were not statistically different ( P =0.9). No correlation was found between optical density and depth of the FR. Conclusion: Successful scleral lens wear can occur with a wide range of FR depths. Experienced practitioners can accurately estimate FR depth using slitlamp examination. Midday fogging due to debris behind a scleral lens was not related to FR depth in this group of habitual wearers.
- 14 April 2026
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 52 (6) , 217-222
Open AccessFluid Reservoir Characteristics in Established Scleral Lens Wear, Part I—Evaluation of Fluid Reservoir Depth and Midday Fogging
Objectives: Fluid reservoir (FR) depth is an important parameter in the evaluation of scleral lens fitting, yet the range of depths compatible with successful wear, clinicians' ability to estimate depth, and implications of FR depth on midday fogging have yet to be fully elucidated. This study quantified FR depth of habitual scleral lens wearers, compared clinician estimates and image-based measurements of depth, and evaluated optical density of the FR to assess the effect of FR depth on midday fogging. Methods: Habitual scleral lens wearers consented to participate at three sites. FR depth was estimated using slitlamp evaluation by experienced examiners. Measurements of the depth and optical density of the FR were collected using Scheimpflug images. Results: The mean estimated (265±97; range: 0–500 µm) and image-derived (264±111; range: 40–555 µm) FR depths were not statistically different ( P =0.9). No correlation was found between optical density and depth of the FR. Conclusion: Successful scleral lens wear can occur with a wide range of FR depths. Experienced practitioners can accurately estimate FR depth using slitlamp examination. Midday fogging due to debris behind a scleral lens was not related to FR depth in this group of habitual wearers.
- Open Access
- 2 April 2026
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 52 (6) , 223-226
Fluid Reservoir Characteristics in Established Scleral Lens Wear, Part II: Evaluation of Tear Exchange and Midday Fogging
Objectives: Tear exchange is less robust with scleral lenses compared to other modalities. This study evaluates tear exchange with scleral lens wear and examines relationships between tear exchange and optical density of the fluid reservoir and patient-reported midday fogging in established scleral lens wearers. Methods: Participants reported if they experienced midday fogging. Tear exchange was evaluated by observing sodium fluorescein uptake into the post-lens fluid reservoir after 10 seconds, and 1, 2.5, and 5 minutes. Optical density of the fluid reservoir was measured using Scheimpflug imaging. Sensitivity, specificity, and negative and positive predictive value (NPV and PPV) of tear exchange as a predictor for fogging were calculated. Results: Tear exchange occurred within 5 minutes in 64% of eyes. The difference in fluid reservoir optical density for eyes with and without tear exchange was greatest when tear exchange occurred within 10 seconds. Tear exchange between 1-5 minutes was not predictive for fogging. Tear exchange occurring within 10 seconds showed low sensitivity and NPV, but high specificity (87%) and PPV (71%) for predicting fogging. Conclusion: Tear exchange occurred in a majority of eyes in this study. Scleral lens wearers with a rapid tear exchange rate were more likely to report midday fogging.
- 2 April 2026
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 52 (6) , 223-226
Open AccessFluid Reservoir Characteristics in Established Scleral Lens Wear, Part II: Evaluation of Tear Exchange and Midday Fogging
Objectives: Tear exchange is less robust with scleral lenses compared to other modalities. This study evaluates tear exchange with scleral lens wear and examines relationships between tear exchange and optical density of the fluid reservoir and patient-reported midday fogging in established scleral lens wearers. Methods: Participants reported if they experienced midday fogging. Tear exchange was evaluated by observing sodium fluorescein uptake into the post-lens fluid reservoir after 10 seconds, and 1, 2.5, and 5 minutes. Optical density of the fluid reservoir was measured using Scheimpflug imaging. Sensitivity, specificity, and negative and positive predictive value (NPV and PPV) of tear exchange as a predictor for fogging were calculated. Results: Tear exchange occurred within 5 minutes in 64% of eyes. The difference in fluid reservoir optical density for eyes with and without tear exchange was greatest when tear exchange occurred within 10 seconds. Tear exchange between 1-5 minutes was not predictive for fogging. Tear exchange occurring within 10 seconds showed low sensitivity and NPV, but high specificity (87%) and PPV (71%) for predicting fogging. Conclusion: Tear exchange occurred in a majority of eyes in this study. Scleral lens wearers with a rapid tear exchange rate were more likely to report midday fogging.
- Open Access
- 1 February 2026
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 18, 1-12
Predictive Gaze Shifts and Gaze Tracking with Coincidence-Anticipation Timing Responses
Coincidence-anticipation timing (CAT) requires an individual to execute a task at the same time that an approaching object arrives. Previous studies on intercepting a moving object suggest that if the interception location is known, observers quickly shift their gaze to this location. The purpose of this experiment was to qualitatively determine whether a clinical CAT device with a known interception location induces early predictive gaze shifts. CAT responses were measured using a Bassin Anticipation Timer consisting of a linear track of lights (3.58m). The lights illuminated sequentially to simulate movement along the track. A wearable video eye tracker was used to record the participants’ gaze location. Participants pushed a button to coincide with illumination of the final light on the track. CAT responses were assessed in 2 conditions. In the nonrandom condition, participants responded to blocks of 21 consecutive presentations at stimulus velocities of 5mph (8.04km/h), 10mph (16.09km/h), and 20mph (32.18km/h) (63 trials). In the random condition, participants responded to randomized stimulus velocities of 5 to 20mph (64 trials). CAT responses were collected from 20 participants. The relationship between CAT errors and stimulus velocity was best fit with a linear function for the nonrandom condition and with a quadratic function for the random condition. Gaze tracking data were examined for 14 participants. Predictive gaze shifts occurred in 23.6% of the trials in the nonrandom condition and 12.4% of trials in the random condition. In trials with no predictive movements, tracking generally occurred for most of the trajectory. Substantial head movements in the direction of the approaching stimulus occurred regularly for most participants. Predictive gaze movements were uncommon in this coincidence-anticipation timing task. Continuous tracking was the most common gaze strategy. Future studies can explore whether training with CAT devices leads to improved sports performance.
- 1 February 2026
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 18, 1-12
Open AccessPredictive Gaze Shifts and Gaze Tracking with Coincidence-Anticipation Timing Responses
Coincidence-anticipation timing (CAT) requires an individual to execute a task at the same time that an approaching object arrives. Previous studies on intercepting a moving object suggest that if the interception location is known, observers quickly shift their gaze to this location. The purpose of this experiment was to qualitatively determine whether a clinical CAT device with a known interception location induces early predictive gaze shifts. CAT responses were measured using a Bassin Anticipation Timer consisting of a linear track of lights (3.58m). The lights illuminated sequentially to simulate movement along the track. A wearable video eye tracker was used to record the participants’ gaze location. Participants pushed a button to coincide with illumination of the final light on the track. CAT responses were assessed in 2 conditions. In the nonrandom condition, participants responded to blocks of 21 consecutive presentations at stimulus velocities of 5mph (8.04km/h), 10mph (16.09km/h), and 20mph (32.18km/h) (63 trials). In the random condition, participants responded to randomized stimulus velocities of 5 to 20mph (64 trials). CAT responses were collected from 20 participants. The relationship between CAT errors and stimulus velocity was best fit with a linear function for the nonrandom condition and with a quadratic function for the random condition. Gaze tracking data were examined for 14 participants. Predictive gaze shifts occurred in 23.6% of the trials in the nonrandom condition and 12.4% of trials in the random condition. In trials with no predictive movements, tracking generally occurred for most of the trajectory. Substantial head movements in the direction of the approaching stimulus occurred regularly for most participants. Predictive gaze movements were uncommon in this coincidence-anticipation timing task. Continuous tracking was the most common gaze strategy. Future studies can explore whether training with CAT devices leads to improved sports performance.
- Open Access
- 1 September 2025
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 17, 307-313
Wear Experience with a Silicone Hydrogel 1-Week Replacement Lens in Current Wearers of a 2-Week Replacement Lens
Purpose: More frequent replacement of contact lenses may be beneficial for ocular health, but satisfied wearers often have prescriptions renewed in the same lens. This study sought to evaluate the wear experience of a newly released 1-week replacement lens among currently satisfied wearers of a 2-week replacement lens. Methods: This open-label, non-comparative study of single vision lenses recruited satisfied wearers of senofilcon A and refit them in serafilcon A. Participants wore the study lenses for two weeks. Assessments included visual acuity and surveys regarding wear experience: the Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8); visual analog scale (VAS) ratings of vision quality and comfort; VAS ratings of vision and comfort during a variety of activities; and ratings of convenience, satisfaction and ease of use on a 0 to 10 Likert scale. Results: Sixty-two participants completed the study. Median (interquartile range) distance LogMAR acuity with the study lenses was − 0.15 (0.12) OD, − 0.16 (0.10) OS, and − 0.22 (0.08) OU. The median (IQR) CLDEQ-8 score was 10 (10). Median (IQR) VAS responses were 91 (22) for overall quality of vision and 83 (30), for overall comfort. Median VAS responses regarding specific activities ranged from 87 to 91 for vision and 81 to 90 for comfort. Median (IQR) ratings were 8 (2) for convenience, 10 (1) for ease of use, and 9 (2) for satisfaction. Conclusion: In this study, satisfied wearers of a commonly prescribed 2-week replacement soft contact lens reported median wear experience VAS scores in the upper quartile for all assessments of vision and comfort and a median CLDEQ-8 score below that associated with dryness. Findings suggest that these lenses are a viable option for practitioners interested in the weekly replacement modality of soft lenses.
- 1 September 2025
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 17, 307-313
Open AccessWear Experience with a Silicone Hydrogel 1-Week Replacement Lens in Current Wearers of a 2-Week Replacement Lens
Purpose: More frequent replacement of contact lenses may be beneficial for ocular health, but satisfied wearers often have prescriptions renewed in the same lens. This study sought to evaluate the wear experience of a newly released 1-week replacement lens among currently satisfied wearers of a 2-week replacement lens. Methods: This open-label, non-comparative study of single vision lenses recruited satisfied wearers of senofilcon A and refit them in serafilcon A. Participants wore the study lenses for two weeks. Assessments included visual acuity and surveys regarding wear experience: the Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8); visual analog scale (VAS) ratings of vision quality and comfort; VAS ratings of vision and comfort during a variety of activities; and ratings of convenience, satisfaction and ease of use on a 0 to 10 Likert scale. Results: Sixty-two participants completed the study. Median (interquartile range) distance LogMAR acuity with the study lenses was − 0.15 (0.12) OD, − 0.16 (0.10) OS, and − 0.22 (0.08) OU. The median (IQR) CLDEQ-8 score was 10 (10). Median (IQR) VAS responses were 91 (22) for overall quality of vision and 83 (30), for overall comfort. Median VAS responses regarding specific activities ranged from 87 to 91 for vision and 81 to 90 for comfort. Median (IQR) ratings were 8 (2) for convenience, 10 (1) for ease of use, and 9 (2) for satisfaction. Conclusion: In this study, satisfied wearers of a commonly prescribed 2-week replacement soft contact lens reported median wear experience VAS scores in the upper quartile for all assessments of vision and comfort and a median CLDEQ-8 score below that associated with dryness. Findings suggest that these lenses are a viable option for practitioners interested in the weekly replacement modality of soft lenses.
- 2 July 2025
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 51 (10) , 439-444
Slit Lamp Findings in Scleral Lens Wearers With and Without Subjective Fogging
Purpose: The term “midday fogging” is used to describe visual blur, which some scleral lens wearers experience during use. The purpose of this study was to determine whether fit characteristics and biomicroscopic findings in habitual scleral lens wearers contribute to symptoms of fogging. Methods: This prospective, observational study analyzed 48 habitual scleral lens wearers who wore lenses in one or both eyes from five clinical sites. Participants indicated whether they experienced fogging. Slit Lamp biomicroscopy was performed to evaluate fluid reservoir (FR) depth and presence or absence of limbal clearance, edge lift or impingement, conjunctival prolapse, and front surface nonwetting. Presence or absence of mucous strands, fine particulate debris, and diffuse haze in the FR were also noted. Backward elimination binomial logistic regression using one eye per participant compared the findings of eyes with and without subjective fogging. Results: Fogging was reported by 58% participants (28/48). Statistical analysis found no significant differences in scleral lens fitting characteristics of eyes with and without reported fogging. The presence of front surface nonwetting and diffuse haze were statistically higher in eyes with fogging. Conclusion: In this study, front surface nonwetting and diffuse haze observed with Slit Lamp biomicroscopy were associated with patient-reported scleral lens fogging.
- 2 July 2025
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 51 (10) , 439-444
Slit Lamp Findings in Scleral Lens Wearers With and Without Subjective Fogging
Purpose: The term “midday fogging” is used to describe visual blur, which some scleral lens wearers experience during use. The purpose of this study was to determine whether fit characteristics and biomicroscopic findings in habitual scleral lens wearers contribute to symptoms of fogging. Methods: This prospective, observational study analyzed 48 habitual scleral lens wearers who wore lenses in one or both eyes from five clinical sites. Participants indicated whether they experienced fogging. Slit Lamp biomicroscopy was performed to evaluate fluid reservoir (FR) depth and presence or absence of limbal clearance, edge lift or impingement, conjunctival prolapse, and front surface nonwetting. Presence or absence of mucous strands, fine particulate debris, and diffuse haze in the FR were also noted. Backward elimination binomial logistic regression using one eye per participant compared the findings of eyes with and without subjective fogging. Results: Fogging was reported by 58% participants (28/48). Statistical analysis found no significant differences in scleral lens fitting characteristics of eyes with and without reported fogging. The presence of front surface nonwetting and diffuse haze were statistically higher in eyes with fogging. Conclusion: In this study, front surface nonwetting and diffuse haze observed with Slit Lamp biomicroscopy were associated with patient-reported scleral lens fogging.
- Open Access
- 1 July 2025
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 17, 185-193
Refitting Previous Presbyopic Contact Lens Dropouts with a Single Use Multifocal Contact Lens
Purpose: Contact lens dropout is known to occur frequently in presbyopic patients. The purpose of this study was to assess the rate of patient-reported success, defined by willingness to continue lens wear after the study, when fitting previous presbyopic contact lens dropout patients with a single-use multifocal contact lens. Methods: Presbyopes who had previously discontinued contact lens wear due to poor vision were recruited and fit with delefilcon A multifocal contact lenses. Participants were prescribed lenses following the fitting guide, wore lenses for 1 week to allow for adaptation, and returned for a follow-up visit. After confirmation of optimized lens powers, lenses were dispensed for one month of wear. A final visit was completed to assess vision and respond to survey questions, including 0– 100 visual analog scale (VAS) surveys of lens wear experiences. Participants also scored their likelihood of continuing with study lenses upon study completion and whether the participant would recommend the study lenses to a friend. Success with fitting the study lenses was defined as those participants who selected “very likely” or “likely” to continue wearing the study lenses after the conclusion of the study. Results: Twenty-five participants completed all study visits. Median (Interquartile range) binocular LogMAR acuity with the study lenses was − 0.10 (0.16) at distance (20/16 Snellen acuity equivalent) and 0.00 (0.12) at near (20/20 Snellen acuity equivalent). The median (IQR) satisfaction score was 84 (29.75) on a scale of 0– 100. Eighty percent of the participants said they were very likely or likely to continue wearing the multifocal lenses after the conclusion of the study. All twenty-five of the participants said they would recommend the study lenses to a friend. Conclusion: The objective and subjective findings of this study suggest that presbyopic contact lens dropouts can be refit with the study multifocal contact lens.
- 1 July 2025
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 17, 185-193
Open AccessRefitting Previous Presbyopic Contact Lens Dropouts with a Single Use Multifocal Contact Lens
Purpose: Contact lens dropout is known to occur frequently in presbyopic patients. The purpose of this study was to assess the rate of patient-reported success, defined by willingness to continue lens wear after the study, when fitting previous presbyopic contact lens dropout patients with a single-use multifocal contact lens. Methods: Presbyopes who had previously discontinued contact lens wear due to poor vision were recruited and fit with delefilcon A multifocal contact lenses. Participants were prescribed lenses following the fitting guide, wore lenses for 1 week to allow for adaptation, and returned for a follow-up visit. After confirmation of optimized lens powers, lenses were dispensed for one month of wear. A final visit was completed to assess vision and respond to survey questions, including 0– 100 visual analog scale (VAS) surveys of lens wear experiences. Participants also scored their likelihood of continuing with study lenses upon study completion and whether the participant would recommend the study lenses to a friend. Success with fitting the study lenses was defined as those participants who selected “very likely” or “likely” to continue wearing the study lenses after the conclusion of the study. Results: Twenty-five participants completed all study visits. Median (Interquartile range) binocular LogMAR acuity with the study lenses was − 0.10 (0.16) at distance (20/16 Snellen acuity equivalent) and 0.00 (0.12) at near (20/20 Snellen acuity equivalent). The median (IQR) satisfaction score was 84 (29.75) on a scale of 0– 100. Eighty percent of the participants said they were very likely or likely to continue wearing the multifocal lenses after the conclusion of the study. All twenty-five of the participants said they would recommend the study lenses to a friend. Conclusion: The objective and subjective findings of this study suggest that presbyopic contact lens dropouts can be refit with the study multifocal contact lens.
- Open Access
- 1 November 2024
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 16, 267-286
How Can We Better Inform Patients of the Importance of Contact Lens Compliance?: Current Perspectives
Compliance with contact lens care is important for successful contact lens wear and for minimizing the risk of complications related to lens wear. There are many components of overall lens care guidelines that may potentially be disregarded, forgotten, or misunderstood. Literature has reported copious data on rates of poor compliance for separate lens care recommendations. Knowing the areas of contact lens care where lens wearers perform poorly is helpful when creating strategies for improving patient education. As science evolves and new best-practices are determined, eye care providers must be engaged in educating new lens wearers and reeducating existing wearers. It is vital to make wearers mindful of proper lens care and why proper lens care should be important to them. Various educational strategies can help practitioners to communicate with their patients more effectively. The purpose of this narrative review is to discuss studies of noncompliance with contact lens wear; consequences of these noncompliant behaviors; and studies of lens care education which were found with a literature search. The resulting discussion also includes strategies to improve compliance with patient contact lens wear.
- 1 November 2024
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 16, 267-286
Open AccessHow Can We Better Inform Patients of the Importance of Contact Lens Compliance?: Current Perspectives
Compliance with contact lens care is important for successful contact lens wear and for minimizing the risk of complications related to lens wear. There are many components of overall lens care guidelines that may potentially be disregarded, forgotten, or misunderstood. Literature has reported copious data on rates of poor compliance for separate lens care recommendations. Knowing the areas of contact lens care where lens wearers perform poorly is helpful when creating strategies for improving patient education. As science evolves and new best-practices are determined, eye care providers must be engaged in educating new lens wearers and reeducating existing wearers. It is vital to make wearers mindful of proper lens care and why proper lens care should be important to them. Various educational strategies can help practitioners to communicate with their patients more effectively. The purpose of this narrative review is to discuss studies of noncompliance with contact lens wear; consequences of these noncompliant behaviors; and studies of lens care education which were found with a literature search. The resulting discussion also includes strategies to improve compliance with patient contact lens wear.
- 29 May 2024
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 50 (7) , 292-296
Image- and Impression-Based Technology in Scleral Lens Fitting for Keratoconus: Availability and Utilization
Objective: Scleral lenses (SLs) can be customized using traditional diagnostic lens fitting or by using image- and/or impression-based technologies. This study describes the availability and usage of SL fitting technology in patients with keratoconus. Methods: An online survey queried practitioners on the mode of practice, country of residence, and estimated number of SL fits completed for keratoconus. Practitioners were asked whether they had access to image- and/or impression-based technology and to estimate the percentage of fits completed using diagnostic fitting, image-based technology, and impression-based technology. Access and usage of technology was compared between academic and community practices, United States and non–United States, and high-volume (≥60 SLs) and low-volume fitters. Results: 423 practitioners who fit SL for keratoconus participated. Image- and impression-based technologies were more frequently available in academic practices compared with community practices and high-volume compared with low-volume practitioners (P<0.005). Practitioners with image-based technology used it for a median [interquartile range] 5 [25]% of SL fittings; those with impression-based technology used it for 8 [9]% of fittings, and those with both types of technology used image-based devices for 12 [23]% of fittings and impression-based for 5 [8]% of fittings. Conclusions: In this study, most participants report using diagnostic lenses to fit SLs for patients with keratoconus.
- 29 May 2024
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 50 (7) , 292-296
Image- and Impression-Based Technology in Scleral Lens Fitting for Keratoconus: Availability and Utilization
Objective: Scleral lenses (SLs) can be customized using traditional diagnostic lens fitting or by using image- and/or impression-based technologies. This study describes the availability and usage of SL fitting technology in patients with keratoconus. Methods: An online survey queried practitioners on the mode of practice, country of residence, and estimated number of SL fits completed for keratoconus. Practitioners were asked whether they had access to image- and/or impression-based technology and to estimate the percentage of fits completed using diagnostic fitting, image-based technology, and impression-based technology. Access and usage of technology was compared between academic and community practices, United States and non–United States, and high-volume (≥60 SLs) and low-volume fitters. Results: 423 practitioners who fit SL for keratoconus participated. Image- and impression-based technologies were more frequently available in academic practices compared with community practices and high-volume compared with low-volume practitioners (P<0.005). Practitioners with image-based technology used it for a median [interquartile range] 5 [25]% of SL fittings; those with impression-based technology used it for 8 [9]% of fittings, and those with both types of technology used image-based devices for 12 [23]% of fittings and impression-based for 5 [8]% of fittings. Conclusions: In this study, most participants report using diagnostic lenses to fit SLs for patients with keratoconus.