A Feature Selection Method for Vision-Based Blood Pressure Measurement
Authors:
- Yu-Fan FangYFYu-Fan Fang
- Po-Wei HuangPHPo-Wei Huang
- Meng-Liang ChungMCMeng-Liang Chung
- Bing-Fei WuBWBing-Fei Wu
- 1 October 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2158-2163
Abstract
In this paper we investigate the latest vision-based method for systolic blood pressure (SBP) and diastolic blood pressure (DBP) measurement. However, constantly blood pressure supervision needs sufficient medical equipment and may require the potential patients to tie a cuff, which is extremely inconvenient for them. What's more, continuously blood pressure measuring requires the patients to stay in the hospital and professional personnel to stand by. From the research before, we have learned that photoplethysmography (PPG) can be used to measure the blood pressure, which is known as cuffless blood pressure measurement. However, for the neonate and patients with empyrosis, photoplethysmography measuring device is still less practical and restricted in use due to the necessary contact for it to measure the systolic and diastolic blood pressure. Certain level of discomfort is still unavoidable with the use of PPG. We thus focus on remote PPG (rPPG); with green red difference (GRD) and Euler video magnification (EVM) and finite impulse response (FIR) bandpass filters, we are able to recover PPG signals from remote photoplethysmography. We propose a feature extraction measuring methods which yields a root mean square error for SBP as 11.22 mmHg and 7.83 mmHg for pulse pressure (PP) combined with the ANN model. For comparison, we've also used K nearest neighbor (KNN) and deep belief network-deep neural network (DBN-DNN).Keywords
This publication has 16 references indexed in Scilit:
- Algorithmic Principles of Remote PPGIEEE Transactions on Biomedical Engineering, 2016
- Global Disparities of Hypertension Prevalence and ControlCirculation, 2016
- Cuff-free blood pressure estimation using pulse transit time and heart rate2014
- Robust Pulse Rate From Chrominance-Based rPPGIEEE Transactions on Biomedical Engineering, 2013
- Eulerian video magnification for revealing subtle changes in the worldACM Transactions on Graphics, 2012
- A dynamic threshold decision system for stock trading signal detectionApplied Soft Computing, 2011
- 2010 Guidelines of the Taiwan Society of Cardiology for the Management of HypertensionJournal of the Formosan Medical Association, 2010
- Superiority of Ambulatory Over Clinic Blood Pressure Measurement in Predicting MortalityHypertension, 2005
- Effects of Blood Pressure Control on Radial Artery Diameter and Compliance in Hypertensive PatientsAmerican Journal of Hypertension, 1997