PHPo-Wei Huang

Po-Wei Huang

*This is an algorithmically generated author record based on publicly available information.

Po-Wei Huang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Bing-Fei Wu

    National Chiao Tung University, Hsinchu, Taiwan

    9 shared publications
  • Meng-Liang Chung

    Department of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu, Taiwan

    8 shared publications
  • Tzu-Min Lin

    Division of Rheumatology, Immunology and Allergy, Department of Internal Medicine, Taipei Medical University Hospital, Taipei, 110, Taiwan

    5 shared publications
  • Bing-Fei Wu

    Institute of Electrical and Control Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan

    3 shared publications
  • Tsong-Yang Tsou

    Institute of Electrical and Control Engineering, National Chiao Tung University, Hsinchu, 30010 Taiwan

    2 shared publications
  • Bing-Jhang Wu

    Institute of Electrical and Control Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan

    1 shared publication

Latest Publications

  • A Heart Rate Monitoring Framework for Real-World Drivers Using Remote Photoplethysmography

    by Po-Wei Huang, Bing-Jhang Wu, Bing-Fei Wu

    Remote photoplethysmography (rPPG) is an unobtrusive solution to heart rate monitoring in drivers. However, disturbances that occur during driving such as driver behavior, motion artifacts, and illuminance variation complicate the monitoring of heart rate. Faced with disturbance, one commonly used assumption is heart rate periodicity (or spectrum sparsity). Several methods improve stability at the expense of tracking sensitivity for heart rate variation. Based on statistical signal processing (SSP) and Monte Carlo simulations, the outlier probability is derived and ADaptive spectral filter banks (AD) is proposed as a new algorithm which provides an explicable tuning option for spectral filter banks to strike a balance between robustness and sensitivity in remote monitoring for driving scenarios. Moreover, we construct a driving database containing over 23 hours of data to verify the proposed algorithm. The influence on rPPG from driver habits (both amateurs and professionals), vehicle types (compact cars and buses), and routes are also evaluated. In comparison to state-of-the-art rPPG for driving scenarios, the mean absolute error in the Passengers, Compact Cars, and Buses scenarios is 3.43, 7.85, and 5.02 beats per minute, respectively.


  • Open Access

    A Region of Interest Selection for Vision-Based Respiratory Rate Measurement in Sleeping Scenario

    by Bing-Fei Wu, Chun-Han Lin, Po-Wei Huang, Kuan-Hung Chen, Da-Hong He

    Vision-based respiratory measurement can remotely measure respiratory information without affecting the sleep quality of the user. However, several scenarios during sleeping, such as when blankets cover areas of the face or body, can be a challenge when estimate respiratory rate (RR) due to the uncertainty of the region of interest (ROI). In this study, we first investigate the metrics and physical meanings of ROI selection from the perspectives of array signal processing and the concept of linear combining. Then, we propose an ROI detection algorithm based on both temporal and spatial consistency (TSC), which aims to extract the representative characteristics of respiration with fewer computational resources. Furthermore, a sleeping database, containing more than 50 hours of data, was built to investigate the performance of benchmarked ROI methods during long-term sleeping. The experimental results demonstrate that TSC attains the highest signal-to-noise ratio (SNR) at 20.6 dB and a relatively low elapsed time of 100.2 frames per second (fps). For the RR estimation accuracy, TSC reduces the mean absolute error from 1.65 breaths per minute (bpm) to 0.97 bpm.


  • Open Access

    Vision-Based Instant Measurement System for Driver Fatigue Monitoring

    by Yin-Cheng Tsai, Peng-Wen Lai, Po-Wei Huang, Tzu-Min Lin, Bing-Fei Wu

    In this paper, a vision-based physiological signal measurement system is proposed to instantly measure driver fatigue. A remote photoplethysmography (rPPG) signal is a type of physiological signal measured by a camera without any contact device, and it also retains the characteristics of the PPG, which is useful to evaluate fatigue. To solve the inconvenience caused by the traditional contact-based physiological fatigue detection system and to improve the accuracy, the system measures both the motional and physiological information by using one image sensor. In a practical application, the environmental noise would affect the measured signal, and therefore, we performed a preprocessing step on the signal to extract a clear signal. The experiment was designed in collaboration with Taipei Medical University, and a questionnaire-based method was used to define fatigue. The questionnaire that could directly react to the feeling of the subject was treated as our ground truth. The evaluated correlation was 0.89 and the root mean square error was 0.65 for ten-fold cross-validation on the dataset. The trend of driver fatigue could be evaluated without a contact device by the proposed system. This advantage ensures the safety of the driver and reliability of the system.


  • Remote HeartRate Measurement based on Signal Feature Detection in Time Domain

    by Bing-Fei Wu, Yin-Yin Yang, Bing-Ruei Tsai, Po-Wei Huang, Yin-Cheng Tsai, Kuan-Hung Chen

    Remote-photoplethysmography (rPPG) is a contactless method which can measure Blood Volume Pulse (BVP) and several vital signals from human faces. Until now, most existing techniques depend on frequency analysis and regard the signal component with largest energy as Heart Rate (HR). Nonetheless, the property, that frequency analysis could not identify the instantaneous HR changes restricts the applications on Heart Rate Variability (HRV) analysis and Cardiac Arrhythmia Detection. Consequently, this paper proposes a time domain systolic peak selection algorithm. It reaches 89% Suc5 in stationary case and 90% Suc10 in indoor scenario which are neck and neck with frequency domain analysis. At the same time, the comparison method, Rei-En, gets Suc10 lower than 80% in both situations. We investigate the influence of dicrotic notch and utilize a concise method to prevent wrong Inter-beat interval (IBI) detection for HR and HRV estimation. Benefiting from the characteristic of time domain analysis, the first HR output could be estimated within five seconds, which is much shorter than seventeen seconds in frequency domain analysis. The results suggest that the proposed algorithm improves instantaneity and provides faster first output of rPPG in HR, HRV estimation.


  • Open Access

    Neural Network Based Luminance Variation Resistant Remote-Photoplethysmography for Driver’s Heart Rate Monitoring

    by Bing-Fei Wu, Yun-Wei Chu, Po-Wei Huang, Meng-Liang Chung

    The driver’s physiological status has enormous value to public traffic safety and cannot be ignored nowadays. In addition, heart rate (HR) is one of the most important indicators of human’s health status. When detecting the driver’s HR, using traditional contact-type devices might bring about the driver’s distraction or discomfort. On the contrary, the remote photoplethysmography (rPPG) technique is a better way to monitor a driver’s HR in vehicle applications simply by using a web-camera without interfering the driver. Most of the rPPG studies intended to reduce the interference caused by facial motion or luminance changes in the indoor or controlled scenario, but there are relatively fewer discussions on outdoor scenarios. Consequently, the purpose of this paper is to enhance the rPPG technique to make it suitable for the outdoor driving scenarios and for monitoring the driver’s HR in different weather conditions, including daytime and nighttime. We first utilize artificial neural network (ANN) and train multiple personalized ANN models for each driver. For predicting the drivers’ HR beat more precisely, we propose the approach, adaptive neural network model selection (ANNMS), which adaptively selects a personalized ANN model based on different noise conditions. Our algorithm eliminates the effect of noises caused by the variations of facial luminance in eight outdoor driving scenarios. The proposed driver’s HR beat monitoring system has been evaluated against the state-of-the-art rPPG techniques that are Chrominance signal-based (CHRO) and k-nearest neighbors-based (kNN) algorithms. Compared with the CHRO and kNN algorithms, the ANNMS reduces the mean absolute error from 14.71 bpm (CHRO) and 9.91 (kNN) to 4.51 bpm (ANNMS) and enhances the success-rate-10, the probability in which the absolute error is below 10 bpm, from 44.1% (CHRO) and 56.3% (kNN) to 91.5% (ANNMS).


  • A Feature Selection Method for Vision-Based Blood Pressure Measurement

    by Yu-Fan Fang, Po-Wei Huang, Meng-Liang Chung, Bing-Fei Wu

    In this paper we investigate the latest vision-based method for systolic blood pressure (SBP) and diastolic blood pressure (DBP) measurement. However, constantly blood pressure supervision needs sufficient medical equipment and may require the potential patients to tie a cuff, which is extremely inconvenient for them. What's more, continuously blood pressure measuring requires the patients to stay in the hospital and professional personnel to stand by. From the research before, we have learned that photoplethysmography (PPG) can be used to measure the blood pressure, which is known as cuffless blood pressure measurement. However, for the neonate and patients with empyrosis, photoplethysmography measuring device is still less practical and restricted in use due to the necessary contact for it to measure the systolic and diastolic blood pressure. Certain level of discomfort is still unavoidable with the use of PPG. We thus focus on remote PPG (rPPG); with green red difference (GRD) and Euler video magnification (EVM) and finite impulse response (FIR) bandpass filters, we are able to recover PPG signals from remote photoplethysmography. We propose a feature extraction measuring methods which yields a root mean square error for SBP as 11.22 mmHg and 7.83 mmHg for pulse pressure (PP) combined with the ANN model. For comparison, we've also used K nearest neighbor (KNN) and deep belief network-deep neural network (DBN-DNN).


  • Open Access

    Motion Resistant Image-Photoplethysmography Based on Spectral Peak Tracking Algorithm

    by Bing-Fei Wu, Po-Wei Huang, Chun-Hsien Lin, Meng-Liang Chung, Tsong-Yang Tsou, Yu-Liang Wu

    Medical fields have seen increasing attention being given to image based heart rate measurement in recent years. One of the major limitations is motion artifacts of subject‘s head. Although there have been many studies focusing on signal extraction using different parameters and models, the development of frequency domain analysis is emerging slowly and moving in many directions. In the field of contact photoplethysmography (PPG), recent studies employed the acceleration signals to assist their spectral peak tracking algorithms. Inspired by the development of contact PPG, we are proposing a motion resistant spectral peak tracking (MRSPT) framework which eliminates the motion artifacts by integrating facial motion signals. The effectiveness of MRSPT coupled with the optimal iPPG signal has been tested against the state-of-the-art spectral peak tracking algorithms, multi-channel spectral matrix decomposition (MC-SMD), and the maximum peak selection coupled with optimal iPPG signal (Optimal MPS). Compared with MC-SMD and Optimal MPS, MRSPT uplifts the success rate-10 (success rate-5), the probability in which the absolute error is below ten (five) beats per minutes, from 54.7% (36.3%) with MC-SMD and 73.0% (61.3%) with Optimal MPS to 90.7% (75.7%) with MRSPT in motion scenarios where subject moves arbitrarily with different distance or lighting. MRSPT also enhances the success rate-10 (success rate-5) from 40.7% (26.3%) with MC-SMD and 57.4% (45.7%) with Optimal MPS to 73.4% (58.4%) with MRSPT in all seven motion conditions including driving and running. Averagely, the success rate-5 of Optimal MRSPT surpass the success rate-10 of both Optimal MPS and MC-SMD.


  • Image based contactless blood pressure assessment using Pulse Transit Time

    by Po-Wei Huang, Chun-Hao Lin, Meng-Liang Chung, Tzu-Min Lin, Bing-Fei Wu

    Recent years have seen increased attention being given to Blood Pressure (BP) monitoring. Among all kinds of measurements, the monitors based on Pulse Transit Time (PTT) have gain plenty of attention due to its continuous and cuffless features. Additionally, several studies proposed a fancy way to estimate photoplethysmography (PPG) signal simply via a regular webcam. Nevertheless, literatures on issues of integrating these two advanced techniques have emerged on a slowly and scattered way. Furthermore, accuracy of BP prediction model based on PTT is often limited due to the lack of data. To address the above-mentioned problems, we proposed an image based BP measurement algorithm using k-nearest neighbor and transfer learning results from MIMICII database to real task. The study also introduces newly defined PTT features which are especially suitable for image based PPG and domain adaptation. Compared with the state-of-the-art algorithm, root mean square error of SBP evaluation has been reduced from 15.08 to 14.02.


  • A contactless sport training monitor based on facial expression and remote-PPG

    by Bing-Fei Wu, Chun-Hsien Lin, Po-Wei Huang, Tzu-Min Lin, Meng-Liang Chung

    To successfully increase athletes' or exercisers' fitness and endurance, the factors of physiological signal, emotion, or the level of fatigue should be considered during the training program. Many clinical decision support systems can assist to monitor the exercisers by some wearable devices. And, the questionnaire should also be taken into account to produce a report. Such process is cumbersome, and the results are not objective. Furthermore, one may feel uncomfortable when wearing the devices during the training program. In this research, the Rating of Perceived Exertion (RPE) is expected to be estimated automatically without any wearable devices and questionnaires. A camera based heart rate detection algorithm and a fatigue expression feature extractor are fused to estimate the RPE value. The results show that our heart rate detection algorithm can be competitive to the wearable devices, and the trend of the detected heart rate is correlated to RPE. Moreover, the fatigue feature can help reduce the error of the estimation.


  • Camera-based Heart Rate measurement using continuous wavelet transform

    by Bing-Fei Wu, Po-Wei Huang, Tsong-Yang Tsou, Tzu-Min Lin, Meng-Liang Chung

    Recent years have seen increased attention being given to measure Heart Rate with remote-PPG. Previous work mainly focused on optimal signal extraction from three channels of a webcam. Several robust signal extraction methods using either optic models or frequency analysis have been discussed before. After applied these algorithms, residual noise still emerges occasionally with short time duration and relative high energy. This paper investigates the cause of residual noise and then proposed an algorithm based on continuous wavelet transform (CWT) to reduce the highly dynamic residual noise. With noise reduction and signal reconstruction, the advantages of both CWT and FFT are integrated to cope with the motion/illuminance induced residual noise. The results obtained by this system show improved SNR ratio and Entropy under both motion and stationary conditions.