Abstract
Smart contact lenses with continuous intraocular pressure (IOP) sensors are emerging as an alternate system for monitoring the progression and treatment of glaucoma. To date, such sensors have primarily consisted of strain gauges embedded on traditional contact lenses. This work presents a novel smart contact lens design consisting of a ring-shaped contact lens with a piezoresistive strain gauge. We observe an increase in IOP measurement sensitivity of the device with an increase inner diameter of the ring. Ring-shaped sensors with an inner diameter of 2.7 mm show an increase in sensitivity of up to 7.1% and ring-shaped sensors with an inner diameter of 4.7 mm show an increase in sensitivity of up to 17.9%. It is expected that by incorporating a ring-shaped lens, other strain gauge-based smart contact lenses in the literature would experience similar increase in sensitivity.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
- Queen’s University Research Leaders Fund
This publication has 22 references indexed in Scilit:
- Soft wearable contact lens sensor for continuous intraocular pressure monitoringMedical Engineering & Physics, 2014
- Circadian Pattern of Intraocular Pressure Fluctuations in Young Myopic Eyes With Open-Angle GlaucomaInvestigative Ophthalmology & Visual Science, 2014
- Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineeringJournal of Micromechanics and Microengineering, 2014
- Wearable multifunctional sensors using printed stretchable conductors made of silver nanowiresNanoscale, 2013
- Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoringSensors and Actuators A: Physical, 2013
- 24-Hour Intraocular Pressure Rhythm in Young Healthy Subjects Evaluated With Continuous Monitoring Using a Contact Lens SensorJAMA Ophthalmology, 2013
- Materials characterization and mechanobiology of the eyeMaterials Science and Engineering: C, 2013
- GlaucomaThe Lancet, 2011
- In vitro measurement of corneal strain, thickness, and curvature using digital image processingActa Ophthalmologica Scandinavica, 1995
- A comparison of the elastic properties of human choroid and scleraExperimental Eye Research, 1988