The impact of reference isocentre position on set-up errors in head-and-neck image guided radiotherapy
Authors:
Preprint
Abstract
Aim: To examine and quantify set-up errors in patient positioning in head-and-neck radiotherapy and to investigate the impact of the choice of reference isocentre -- on the patient neck or patient skull -- on the magnitude of set-up errors. Materials and methods: Set-up position corrections obtained using online kV 2D/2D matching were recorded automatically for every treatment fraction. 3413 treatment records for 117 patients treated with volumetric modulated arc therapy (VMAT) during 2013 and 2014 on a single treatment machine in our clinic were analysed. In 79 treatment plans the reference isocentre was set to the patient skull, and in 47 to the neck. Results: Standard deviation of group systematic error in the vertical, longitudinal and lateral direction and the couch rotation were found to be 2.5 mm, 2.1 mm, 1.9 mm and 0.43° (skull) and 2.5 mm, 1.8 mm, 1.7 mm and 0.49° (neck). Random error of the vertical, longitudinal, lateral and rotational position correction was 1.8 mm, 1.5 mm, 1.6 mm and 0.62° (skull) and 1.9 mm, 1.6 mm, 1.5 mm and 0.60° (neck). Positional shifts in different directions were found to be uncorrelated. Conclusions: Neither reference isocentre set-up shows a clear advantage over the other in terms of interfraction set-up error.Keywords
All Related Versions
- Version 1, 2023-02-27, ArXiv
- Published version: Journal of Radiotherapy in Practice, 17 (1), 104.
This publication has 22 references indexed in Scilit:
- Set-up errors in head and neck cancer patients treated with intensity modulated radiation therapy: Quantitative comparison between three-dimensional cone-beam CT and two-dimensional kilovoltage imagesPhysica Medica, 2015
- Effects of remedies made in patient setup process on residual setup errors and margins in head and neck cancer radiotherapy based on 2D image guidanceReports of Practical Oncology and Radiotherapy, 2015
- Analysis of Online and Offline Head and Neck Image-guided Radiation TherapyJournal of Medical Imaging and Radiation Sciences, 2014
- Evaluation of set-up errors in head and neck radiotherapy using electronic portal imagingPhysica Medica, 2013
- Image Guidance During Head-and-Neck Cancer Radiation Therapy: Analysis of Alignment Trends With In-Room Cone-Beam Computed Tomography ScansInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- A comparison of kV and MV imaging in head and neck image guided radiotherapyRadiography, 2010
- Setup Uncertainties of Anatomical Sub-Regions in Head-and-Neck Cancer Patients After Offline CBCT GuidanceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Phantom and in-vivo measurements of dose exposure by image-guided radiotherapy (IGRT): MV portal images vs. kV portal images vs. cone-beam CTRadiotherapy and Oncology, 2007
- Analysis of interfractional set-up errors and intrafractional organ motions during IMRT for head and neck tumors to define an appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-marginsRadiotherapy and Oncology, 2006
- A verification procedure to improve patient set-up accuracy using portal imagesRadiotherapy and Oncology, 1993