    Vrednotenje sintetičnih računalniškotomografskih slik za načrtovanje radioterapije glave in vratu z izključno uporabo magnetne resonance

    by Gašper Podobnik, Rok Marko Šter, Primož Peterlin, Primož Strojan, Tomaž Vrtovec

    Izhodišča: Koncept radioterapije z izključno uporabo magnetne resonance (MR) temelji na opustitvi računalniškotomografskih (CT) slik in njihovem nadomeščanju s sintetičnimi CT (sCT) slikami. V tem članku predstavljamo ustvarjanje sCT slik na podlagi MR slik glave in vratu ter pripadajočo geometrijsko in dozimetrično analizo segmentacij kritičnih organov v CT in sCT slikah. Metode: Z algoritmom globokega učenja, ki temelji na difuzijskem procesu, smo ustvarili model na 42 parih ter ga nato uporabili na 12 parih CT in MR slik za ustvarjanje pripadajočih sCT slik iz naključne slike šuma ter s pogojevanjem z MR sliko. V CT in sCT slikah smo nato z modelom globokega učenja avtomatsko segmentirali 12 različnih kritičnih organov ter opravili geometrijsko (računanje prostorskega ujemanja pridobljenih segmentacij v slikah) in dozimetrično (računanje prejetih odmerkov obsevanja pridobljenih segmentacij iz pripadajočih načrtov porazdelitve obsevalnih odmerkov) vrednotenje. Rezultati: Ustvarjene sCT slike so po kakovosti primerljive z obstoječimi metodami: srednja absolutna napaka 43,4 HU, vršno razmerje signal-šum 30,6 dB in indeks strukturne podobnosti 91,2 %. Geometrijska analiza segmentacij kritičnih organov je pokazala visoko ujemanje med CT in sCT slikami: koeficient podobnosti Dice 87,9 % in 95. percentil Hausdorffove razdalje 2,2 mm. Ravno tako je dozimetrična analiza pokazala majhne razlike med obsevalnimi odmerki za CT in sCT slike: relativna razlika povprečnega odmerka je 2,3 % oz. največjega odmerka 1,9 %. Zaključek: Ustvarjanje sCT slik na podlagi predstavljene metodologije daje spodbudne rezultate, ki kažejo, da so sCT slike ustrezna alternativa originalnim CT slikam z vidika geometrijske in dozimetrične analize pripadajočih segmentacij kritičnih organov.

  • Open Access

    Dosimetric assessment of deep learning based organ-at-risk segmentation: insights from the HaN-Seg challenge

    by Gašper Podobnik, Bulat Ibragimov, Primož Peterlin, Primož Strojan, Tomaž Vrtovec


  • Open Access

    PET/CT and MR Improve Interobserver Agreement in Primary Tumor Determination for Radiotherapy in Esophageal Squamous Cell Cancer

    by Ajra Secerov-Ermenc, Primoz Peterlin, Vaneja Velenik, Ana Jeromen-Peressutti, Jasna But-Hadzic, Franc Anderluh, Barbara Segedin

    Background/Objectives: The aim of the study was to evaluate interobserver variability in the determination of the primary tumor for radiotherapy treatment planning in esophageal squamous cell carcinoma (ESCC). Methods: Sixteen patients with locally advanced ESCC were included in the analysis. In all patients positron emission tomography with computed tomography (PETC/CT) and magnetic resonance (MR) scans for radiotherapy planning were performed. Five experienced radiation oncologists delineated the primary tumor based on CT alone, MR alone, PET/CT, CT with fused MR and PET/CT with fused MR. Mean tumor volumes were calculated for each patient and imaging modality. The generalized conformity index (CIgen) was calculated to assess agreement in tumor determination. Results: The mean tumor volumes and CIgen for CT alone, MR alone, PET/CT, CT with fused MR and PET/CT with fused MR were 33.1 cm3, 30.2 cm3, 38.1 cm3, 31.9 cm3, 36.2 cm3 and 0.59, 0.64, 0.66, 0.63, 0.71, respectively. CIgen was significantly higher using PET/CT with fused MR compared to CT (p < 0.001) and PET/CT (p = 0.002) and using PET/CT compared to CT (alone) (p = 0.003). Conclusions: Our study showed higher agreement in primary tumor determination in ESCC using PET/CT compared to CT alone. Higher agreement was also found using PET/CT with fused MR compared to CT alone and PET/CT.


  • Multimodal CT and MR Segmentation of Head and Neck Organs-at-Risk

    by Gašper Podobnik, Primož Strojan, Primož Peterlin, Bulat Ibragimov, Tomaž Vrtovec


  • Open Access

    The impact of reference isocentre position on set-up errors in head-and-neck image guided radiotherapy

    by Helena Lenko, Primož Peterlin

    Aim: To examine and quantify set-up errors in patient positioning in head-and-neck radiotherapy and to investigate the impact of the choice of reference isocentre -- on the patient neck or patient skull -- on the magnitude of set-up errors. Materials and methods: Set-up position corrections obtained using online kV 2D/2D matching were recorded automatically for every treatment fraction. 3413 treatment records for 117 patients treated with volumetric modulated arc therapy (VMAT) during 2013 and 2014 on a single treatment machine in our clinic were analysed. In 79 treatment plans the reference isocentre was set to the patient skull, and in 47 to the neck. Results: Standard deviation of group systematic error in the vertical, longitudinal and lateral direction and the couch rotation were found to be 2.5 mm, 2.1 mm, 1.9 mm and 0.43° (skull) and 2.5 mm, 1.8 mm, 1.7 mm and 0.49° (neck). Random error of the vertical, longitudinal, lateral and rotational position correction was 1.8 mm, 1.5 mm, 1.6 mm and 0.62° (skull) and 1.9 mm, 1.6 mm, 1.5 mm and 0.60° (neck). Positional shifts in different directions were found to be uncorrelated. Conclusions: Neither reference isocentre set-up shows a clear advantage over the other in terms of interfraction set-up error.

  • [OA176] The CBCT protocol of EFOMP-ESTRO-IAEA is alive: Update by eurados and din

    by Hugo de Las Heras Gala, Alberto Torresin, Alexandru Dasu, Osvaldo Rampado, Harry Delis, Irene Hernandez Giron, Chrsitie Theodorakou, Jonas Andersson, John Holroyd, Sue Edyvean, et al.

  • The impact of reference isocentre position on set-up errors in head-and-neck image-guided radiotherapy

    by Helena Lenko, Primož Peterlin

    Aim: To examine and quantify set-up errors in patient positioning in head-and-neck radiotherapy and to investigate the impact of the choice of reference isocentre—on the patient neck or patient skull—on the magnitude of set-up errors.Materials and methods: Set-up position corrections obtained using online kV 2D/2D matching were recorded automatically for every treatment fraction. 3,413 treatment records for 117 patients treated with volumetric modulated arc therapy during 2013 and 2014 on a single treatment machine in our clinic were analysed. In 79 treatment plans the reference isocentre was set to the patient skull, and in 47 to the neck.Results: Standard deviation of group systematic error in the vertical, longitudinal and lateral direction and the couch rotation were found to be 2·5 mm, 2·1 mm, 1·9 mm and 0·43° (skull) and 2·5 mm, 1·8 mm, 1·7 mm and 0·49° (neck), respectively. Random error of the vertical, longitudinal, lateral and rotational position correction was 1·8 mm, 1·5 mm, 1·6 mm and 0·62° (skull) and 1·9 mm, 1·6 mm, 1·5 mm and 0·60° (neck), respectively. Positional shifts in different directions were found to be uncorrelated.Conclusions: Neither reference isocentre set-up shows a clear advantage over the other in terms of interfraction set-up error.


  • Influence of the Integral Quality Monitor transmission detector on high energy photon beams: A multi-centre study

    by Bozidar Casar, Marlies Pasler, Sonja Wegener, David Hoffman, Cinzia Talamonti, Jianguo Qian, Ignasi Mendez, Denis Brojan, Bruce Perrin, Martijn Kusters, et al.


  • Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report)

    by Hugo de Las Heras Gala, Alberto Torresin, Alexandru Dasu, Osvaldo Rampado, Harry Delis, Irene Hernández Girón, Chrysoula Theodorakou, Jonas Andersson, John Holroyd, Mats Nilsson, et al.


  • Open Access

    Treating lung cancer with dynamic conformal arc therapy: a dosimetric study

    by Primož Peterlin, Karmen Stanič, Ignasi Méndez, Andrej Strojnik

    Lung cancer patients are often in poor physical condition, and a shorter treatment time would reduce their discomfort. Dynamic conformal arc therapy (DCAT) offers a shorter treatment time than conventional 3D conformal radiotherapy (3D CRT) and is usually available even in departments without inverse planning possibilities. We examined its suitability as a treatment modality for lung cancer patients. On a cohort of 35 lung cancer patients, relevant dosimetric parameters were compared in respective DCAT and 3D CRT treatment plans. Radiochromic film dosimetry in an anthropomorphic phantom was used to compare both DCAT and 3D CRT dose distributions against their planned counterparts. In comparison with their 3D CRT counterparts, DCAT plans equal or exceed the agreement between the calculated dose and the dose measured using film dosimetry. In dosimetric comparison, DCAT performed significantly better than 3D CRT in dose conformity to PTV and the number of monitor units used per plan, and significantly worse in dose homogeneity, mean lung dose and lung volume exposed to 5 Gy or more (V5Gy). No significant difference was found in the V20Gy value to lung, dose to 1 cm3 of spinal cord, and the mean dose to oesophagus. Improvements in V20Gy and V5Gy were found to be negatively correlated. DCAT plans differ from 3D CRT by exhibiting a moderate negative correlation between target volume sphericity and dose homogeneity. With respect to the agreement between the planned and the irradiated dose distribution, DCAT appears at least as reliable as 3D CRT. In specific conditions concerning the patient anatomy and treatment prescription, DCAT may yield more favourable dosimetric parameters. On average, however, conventional 3D CRT usually obtains better dosimetric parameters. We can thus only recommend DCAT as a complementary technique to the conventional 3D CRT.