Primož Peterlin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Primož Peterlin has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
Vesna Arrigler
Faculty of Medicine, Institute of Biophysics, University of Ljubljana, Lipičeva 2, Ljubljana, Slovenia
5 shared publications- Ignasi Méndez
Department of Medical Physics, Institute of Oncology Ljubljana, Zaloška cesta 2, Ljubljana 1000, Slovenia
4 shared publications Andrej Strojnik
Institute of Oncology Ljubljana, Zaloška 2, Ljubljana, SI-1000, Slovenia
3 shared publications- Gašper Podobnik
University of Ljubljana
3 shared publications - Primož Strojan
Institute of Oncology Ljubljana, Ljubljana, Slovenia
3 shared publications Saša Svetina
Institute of Biophysics, Faculty of Medicine, University of Ljubljana, Slovenia, 1000 Ljubljana, Slovenia
3 shared publications
Latest Publications
- Open Access
- 28 February 2026
- Published by Slovenian Medical Association in Slovenian Medical Journal
- Vol. 95 (1-2) , 3-14
Vrednotenje sintetičnih računalniškotomografskih slik za načrtovanje radioterapije glave in vratu z izključno uporabo magnetne resonance
Izhodišča: Koncept radioterapije z izključno uporabo magnetne resonance (MR) temelji na opustitvi računalniškotomografskih (CT) slik in njihovem nadomeščanju s sintetičnimi CT (sCT) slikami. V tem članku predstavljamo ustvarjanje sCT slik na podlagi MR slik glave in vratu ter pripadajočo geometrijsko in dozimetrično analizo segmentacij kritičnih organov v CT in sCT slikah. Metode: Z algoritmom globokega učenja, ki temelji na difuzijskem procesu, smo ustvarili model na 42 parih ter ga nato uporabili na 12 parih CT in MR slik za ustvarjanje pripadajočih sCT slik iz naključne slike šuma ter s pogojevanjem z MR sliko. V CT in sCT slikah smo nato z modelom globokega učenja avtomatsko segmentirali 12 različnih kritičnih organov ter opravili geometrijsko (računanje prostorskega ujemanja pridobljenih segmentacij v slikah) in dozimetrično (računanje prejetih odmerkov obsevanja pridobljenih segmentacij iz pripadajočih načrtov porazdelitve obsevalnih odmerkov) vrednotenje. Rezultati: Ustvarjene sCT slike so po kakovosti primerljive z obstoječimi metodami: srednja absolutna napaka 43,4 HU, vršno razmerje signal-šum 30,6 dB in indeks strukturne podobnosti 91,2 %. Geometrijska analiza segmentacij kritičnih organov je pokazala visoko ujemanje med CT in sCT slikami: koeficient podobnosti Dice 87,9 % in 95. percentil Hausdorffove razdalje 2,2 mm. Ravno tako je dozimetrična analiza pokazala majhne razlike med obsevalnimi odmerki za CT in sCT slike: relativna razlika povprečnega odmerka je 2,3 % oz. največjega odmerka 1,9 %. Zaključek: Ustvarjanje sCT slik na podlagi predstavljene metodologije daje spodbudne rezultate, ki kažejo, da so sCT slike ustrezna alternativa originalnim CT slikam z vidika geometrijske in dozimetrične analize pripadajočih segmentacij kritičnih organov.
- 28 February 2026
- Published by Slovenian Medical Association in Slovenian Medical Journal
- Vol. 95 (1-2) , 3-14
Open AccessVrednotenje sintetičnih računalniškotomografskih slik za načrtovanje radioterapije glave in vratu z izključno uporabo magnetne resonance
Izhodišča: Koncept radioterapije z izključno uporabo magnetne resonance (MR) temelji na opustitvi računalniškotomografskih (CT) slik in njihovem nadomeščanju s sintetičnimi CT (sCT) slikami. V tem članku predstavljamo ustvarjanje sCT slik na podlagi MR slik glave in vratu ter pripadajočo geometrijsko in dozimetrično analizo segmentacij kritičnih organov v CT in sCT slikah. Metode: Z algoritmom globokega učenja, ki temelji na difuzijskem procesu, smo ustvarili model na 42 parih ter ga nato uporabili na 12 parih CT in MR slik za ustvarjanje pripadajočih sCT slik iz naključne slike šuma ter s pogojevanjem z MR sliko. V CT in sCT slikah smo nato z modelom globokega učenja avtomatsko segmentirali 12 različnih kritičnih organov ter opravili geometrijsko (računanje prostorskega ujemanja pridobljenih segmentacij v slikah) in dozimetrično (računanje prejetih odmerkov obsevanja pridobljenih segmentacij iz pripadajočih načrtov porazdelitve obsevalnih odmerkov) vrednotenje. Rezultati: Ustvarjene sCT slike so po kakovosti primerljive z obstoječimi metodami: srednja absolutna napaka 43,4 HU, vršno razmerje signal-šum 30,6 dB in indeks strukturne podobnosti 91,2 %. Geometrijska analiza segmentacij kritičnih organov je pokazala visoko ujemanje med CT in sCT slikami: koeficient podobnosti Dice 87,9 % in 95. percentil Hausdorffove razdalje 2,2 mm. Ravno tako je dozimetrična analiza pokazala majhne razlike med obsevalnimi odmerki za CT in sCT slike: relativna razlika povprečnega odmerka je 2,3 % oz. največjega odmerka 1,9 %. Zaključek: Ustvarjanje sCT slik na podlagi predstavljene metodologije daje spodbudne rezultate, ki kažejo, da so sCT slike ustrezna alternativa originalnim CT slikam z vidika geometrijske in dozimetrične analize pripadajočih segmentacij kritičnih organov.
- Open Access
- 23 January 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 217, 111387
Dosimetric assessment of deep learning based organ-at-risk segmentation: insights from the HaN-Seg challenge
- 23 January 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 217, 111387
Open AccessDosimetric assessment of deep learning based organ-at-risk segmentation: insights from the HaN-Seg challenge
- Open Access
- 11 March 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (6) , 690
PET/CT and MR Improve Interobserver Agreement in Primary Tumor Determination for Radiotherapy in Esophageal Squamous Cell Cancer
Background/Objectives: The aim of the study was to evaluate interobserver variability in the determination of the primary tumor for radiotherapy treatment planning in esophageal squamous cell carcinoma (ESCC). Methods: Sixteen patients with locally advanced ESCC were included in the analysis. In all patients positron emission tomography with computed tomography (PETC/CT) and magnetic resonance (MR) scans for radiotherapy planning were performed. Five experienced radiation oncologists delineated the primary tumor based on CT alone, MR alone, PET/CT, CT with fused MR and PET/CT with fused MR. Mean tumor volumes were calculated for each patient and imaging modality. The generalized conformity index (CIgen) was calculated to assess agreement in tumor determination. Results: The mean tumor volumes and CIgen for CT alone, MR alone, PET/CT, CT with fused MR and PET/CT with fused MR were 33.1 cm3, 30.2 cm3, 38.1 cm3, 31.9 cm3, 36.2 cm3 and 0.59, 0.64, 0.66, 0.63, 0.71, respectively. CIgen was significantly higher using PET/CT with fused MR compared to CT (p < 0.001) and PET/CT (p = 0.002) and using PET/CT compared to CT (alone) (p = 0.003). Conclusions: Our study showed higher agreement in primary tumor determination in ESCC using PET/CT compared to CT alone. Higher agreement was also found using PET/CT with fused MR compared to CT alone and PET/CT.
- 11 March 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (6) , 690
Open AccessPET/CT and MR Improve Interobserver Agreement in Primary Tumor Determination for Radiotherapy in Esophageal Squamous Cell Cancer
Background/Objectives: The aim of the study was to evaluate interobserver variability in the determination of the primary tumor for radiotherapy treatment planning in esophageal squamous cell carcinoma (ESCC). Methods: Sixteen patients with locally advanced ESCC were included in the analysis. In all patients positron emission tomography with computed tomography (PETC/CT) and magnetic resonance (MR) scans for radiotherapy planning were performed. Five experienced radiation oncologists delineated the primary tumor based on CT alone, MR alone, PET/CT, CT with fused MR and PET/CT with fused MR. Mean tumor volumes were calculated for each patient and imaging modality. The generalized conformity index (CIgen) was calculated to assess agreement in tumor determination. Results: The mean tumor volumes and CIgen for CT alone, MR alone, PET/CT, CT with fused MR and PET/CT with fused MR were 33.1 cm3, 30.2 cm3, 38.1 cm3, 31.9 cm3, 36.2 cm3 and 0.59, 0.64, 0.66, 0.63, 0.71, respectively. CIgen was significantly higher using PET/CT with fused MR compared to CT (p < 0.001) and PET/CT (p = 0.002) and using PET/CT compared to CT (alone) (p = 0.003). Conclusions: Our study showed higher agreement in primary tumor determination in ESCC using PET/CT compared to CT alone. Higher agreement was also found using PET/CT with fused MR compared to CT alone and PET/CT.
- 1 October 2023
- Published by Springer Nature
- p. 745-755
Multimodal CT and MR Segmentation of Head and Neck Organs-at-Risk
- 1 October 2023
- Published by Springer Nature
- p. 745-755
Multimodal CT and MR Segmentation of Head and Neck Organs-at-Risk
- Open Access
The impact of reference isocentre position on set-up errors in head-and-neck image guided radiotherapy
Aim: To examine and quantify set-up errors in patient positioning in head-and-neck radiotherapy and to investigate the impact of the choice of reference isocentre -- on the patient neck or patient skull -- on the magnitude of set-up errors. Materials and methods: Set-up position corrections obtained using online kV 2D/2D matching were recorded automatically for every treatment fraction. 3413 treatment records for 117 patients treated with volumetric modulated arc therapy (VMAT) during 2013 and 2014 on a single treatment machine in our clinic were analysed. In 79 treatment plans the reference isocentre was set to the patient skull, and in 47 to the neck. Results: Standard deviation of group systematic error in the vertical, longitudinal and lateral direction and the couch rotation were found to be 2.5 mm, 2.1 mm, 1.9 mm and 0.43° (skull) and 2.5 mm, 1.8 mm, 1.7 mm and 0.49° (neck). Random error of the vertical, longitudinal, lateral and rotational position correction was 1.8 mm, 1.5 mm, 1.6 mm and 0.62° (skull) and 1.9 mm, 1.6 mm, 1.5 mm and 0.60° (neck). Positional shifts in different directions were found to be uncorrelated. Conclusions: Neither reference isocentre set-up shows a clear advantage over the other in terms of interfraction set-up error.
Open AccessThe impact of reference isocentre position on set-up errors in head-and-neck image guided radiotherapy
Aim: To examine and quantify set-up errors in patient positioning in head-and-neck radiotherapy and to investigate the impact of the choice of reference isocentre -- on the patient neck or patient skull -- on the magnitude of set-up errors. Materials and methods: Set-up position corrections obtained using online kV 2D/2D matching were recorded automatically for every treatment fraction. 3413 treatment records for 117 patients treated with volumetric modulated arc therapy (VMAT) during 2013 and 2014 on a single treatment machine in our clinic were analysed. In 79 treatment plans the reference isocentre was set to the patient skull, and in 47 to the neck. Results: Standard deviation of group systematic error in the vertical, longitudinal and lateral direction and the couch rotation were found to be 2.5 mm, 2.1 mm, 1.9 mm and 0.43° (skull) and 2.5 mm, 1.8 mm, 1.7 mm and 0.49° (neck). Random error of the vertical, longitudinal, lateral and rotational position correction was 1.8 mm, 1.5 mm, 1.6 mm and 0.62° (skull) and 1.9 mm, 1.6 mm, 1.5 mm and 0.60° (neck). Positional shifts in different directions were found to be uncorrelated. Conclusions: Neither reference isocentre set-up shows a clear advantage over the other in terms of interfraction set-up error.
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 67-68
[OA176] The CBCT protocol of EFOMP-ESTRO-IAEA is alive: Update by eurados and din
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 67-68
[OA176] The CBCT protocol of EFOMP-ESTRO-IAEA is alive: Update by eurados and din
- 2 October 2017
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 17 (1) , 104-113
The impact of reference isocentre position on set-up errors in head-and-neck image-guided radiotherapy
Aim: To examine and quantify set-up errors in patient positioning in head-and-neck radiotherapy and to investigate the impact of the choice of reference isocentre—on the patient neck or patient skull—on the magnitude of set-up errors.Materials and methods: Set-up position corrections obtained using online kV 2D/2D matching were recorded automatically for every treatment fraction. 3,413 treatment records for 117 patients treated with volumetric modulated arc therapy during 2013 and 2014 on a single treatment machine in our clinic were analysed. In 79 treatment plans the reference isocentre was set to the patient skull, and in 47 to the neck.Results: Standard deviation of group systematic error in the vertical, longitudinal and lateral direction and the couch rotation were found to be 2·5 mm, 2·1 mm, 1·9 mm and 0·43° (skull) and 2·5 mm, 1·8 mm, 1·7 mm and 0·49° (neck), respectively. Random error of the vertical, longitudinal, lateral and rotational position correction was 1·8 mm, 1·5 mm, 1·6 mm and 0·62° (skull) and 1·9 mm, 1·6 mm, 1·5 mm and 0·60° (neck), respectively. Positional shifts in different directions were found to be uncorrelated.Conclusions: Neither reference isocentre set-up shows a clear advantage over the other in terms of interfraction set-up error.
- 2 October 2017
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 17 (1) , 104-113
The impact of reference isocentre position on set-up errors in head-and-neck image-guided radiotherapy
Aim: To examine and quantify set-up errors in patient positioning in head-and-neck radiotherapy and to investigate the impact of the choice of reference isocentre—on the patient neck or patient skull—on the magnitude of set-up errors.Materials and methods: Set-up position corrections obtained using online kV 2D/2D matching were recorded automatically for every treatment fraction. 3,413 treatment records for 117 patients treated with volumetric modulated arc therapy during 2013 and 2014 on a single treatment machine in our clinic were analysed. In 79 treatment plans the reference isocentre was set to the patient skull, and in 47 to the neck.Results: Standard deviation of group systematic error in the vertical, longitudinal and lateral direction and the couch rotation were found to be 2·5 mm, 2·1 mm, 1·9 mm and 0·43° (skull) and 2·5 mm, 1·8 mm, 1·7 mm and 0·49° (neck), respectively. Random error of the vertical, longitudinal, lateral and rotational position correction was 1·8 mm, 1·5 mm, 1·6 mm and 0·62° (skull) and 1·9 mm, 1·6 mm, 1·5 mm and 0·60° (neck), respectively. Positional shifts in different directions were found to be uncorrelated.Conclusions: Neither reference isocentre set-up shows a clear advantage over the other in terms of interfraction set-up error.
- 1 September 2017
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 27 (3) , 232-242
Influence of the Integral Quality Monitor transmission detector on high energy photon beams: A multi-centre study
- 1 September 2017
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 27 (3) , 232-242
Influence of the Integral Quality Monitor transmission detector on high energy photon beams: A multi-centre study
- 1 July 2017
- Published by Elsevier in Physica Medica
- Vol. 39, 67-72
Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report)
- 1 July 2017
- Published by Elsevier in Physica Medica
- Vol. 39, 67-72
Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report)
- Open Access
- 2 June 2017
- Published by Springer Nature in Radiation Oncology
- Vol. 12 (1) , 1-14
Treating lung cancer with dynamic conformal arc therapy: a dosimetric study
Lung cancer patients are often in poor physical condition, and a shorter treatment time would reduce their discomfort. Dynamic conformal arc therapy (DCAT) offers a shorter treatment time than conventional 3D conformal radiotherapy (3D CRT) and is usually available even in departments without inverse planning possibilities. We examined its suitability as a treatment modality for lung cancer patients. On a cohort of 35 lung cancer patients, relevant dosimetric parameters were compared in respective DCAT and 3D CRT treatment plans. Radiochromic film dosimetry in an anthropomorphic phantom was used to compare both DCAT and 3D CRT dose distributions against their planned counterparts. In comparison with their 3D CRT counterparts, DCAT plans equal or exceed the agreement between the calculated dose and the dose measured using film dosimetry. In dosimetric comparison, DCAT performed significantly better than 3D CRT in dose conformity to PTV and the number of monitor units used per plan, and significantly worse in dose homogeneity, mean lung dose and lung volume exposed to 5 Gy or more (V5Gy). No significant difference was found in the V20Gy value to lung, dose to 1 cm3 of spinal cord, and the mean dose to oesophagus. Improvements in V20Gy and V5Gy were found to be negatively correlated. DCAT plans differ from 3D CRT by exhibiting a moderate negative correlation between target volume sphericity and dose homogeneity. With respect to the agreement between the planned and the irradiated dose distribution, DCAT appears at least as reliable as 3D CRT. In specific conditions concerning the patient anatomy and treatment prescription, DCAT may yield more favourable dosimetric parameters. On average, however, conventional 3D CRT usually obtains better dosimetric parameters. We can thus only recommend DCAT as a complementary technique to the conventional 3D CRT.
- 2 June 2017
- Published by Springer Nature in Radiation Oncology
- Vol. 12 (1) , 1-14
Open AccessTreating lung cancer with dynamic conformal arc therapy: a dosimetric study
Lung cancer patients are often in poor physical condition, and a shorter treatment time would reduce their discomfort. Dynamic conformal arc therapy (DCAT) offers a shorter treatment time than conventional 3D conformal radiotherapy (3D CRT) and is usually available even in departments without inverse planning possibilities. We examined its suitability as a treatment modality for lung cancer patients. On a cohort of 35 lung cancer patients, relevant dosimetric parameters were compared in respective DCAT and 3D CRT treatment plans. Radiochromic film dosimetry in an anthropomorphic phantom was used to compare both DCAT and 3D CRT dose distributions against their planned counterparts. In comparison with their 3D CRT counterparts, DCAT plans equal or exceed the agreement between the calculated dose and the dose measured using film dosimetry. In dosimetric comparison, DCAT performed significantly better than 3D CRT in dose conformity to PTV and the number of monitor units used per plan, and significantly worse in dose homogeneity, mean lung dose and lung volume exposed to 5 Gy or more (V5Gy). No significant difference was found in the V20Gy value to lung, dose to 1 cm3 of spinal cord, and the mean dose to oesophagus. Improvements in V20Gy and V5Gy were found to be negatively correlated. DCAT plans differ from 3D CRT by exhibiting a moderate negative correlation between target volume sphericity and dose homogeneity. With respect to the agreement between the planned and the irradiated dose distribution, DCAT appears at least as reliable as 3D CRT. In specific conditions concerning the patient anatomy and treatment prescription, DCAT may yield more favourable dosimetric parameters. On average, however, conventional 3D CRT usually obtains better dosimetric parameters. We can thus only recommend DCAT as a complementary technique to the conventional 3D CRT.