Highly accelerated, real‐time phase‐contrast MRI using radial k‐space sampling and GROG‐GRASP reconstruction: a feasibility study in pediatric patients with congenital heart disease
- 24 January 2020
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (5) , e4240
Abstract
Retrospective electrocardiogram‐gated, 2D phase‐contrast (PC) flow MRI is routinely used in clinical evaluation of valvular/vascular disease in pediatric patients with congenital heart disease (CHD). In patients not requiring general anesthesia, clinical standard PC is conducted with free breathing for several minutes per slice with averaging. In younger patients under general anesthesia, clinical standard PC is conducted with breath‐holding. One approach to overcome this limitation is using either navigator gating or self‐navigation of respiratory motion, at the expense of lengthening scan times. An alternative approach is using highly accelerated, free‐breathing, real‐time PC (rt‐PC) MRI, which to date has not been evaluated in CHD patients. The purpose of this study was to develop a 38.4‐fold accelerated 2D rt‐PC pulse sequence using radial k‐space sampling and compressed sensing with 1.5 × 1.5 × 6.0 mm3 nominal spatial resolution and 40 ms nominal temporal resolution, and evaluate whether it is capable of accurately measuring flow in 17 pediatric patients (aortic valve, pulmonary valve, right and left pulmonary arteries) compared with clinical standard 2D PC (either breath‐hold or free breathing). For clinical translation, we implemented an integrated reconstruction pipeline capable of producing DICOMs of the order of 2 min per time series (46 frames). In terms of association, forward volume, backward volume, regurgitant fraction, and peak velocity at peak systole measured with standard PC and rt‐PC were strongly correlated (R2 > 0.76; P < 0.001). Compared with clinical standard PC, in terms of agreement, forward volume (mean difference = 1.4% (3.0% of mean)) and regurgitant fraction (mean difference = −2.5%) were in good agreement, whereas backward volume (mean difference = −1.1 mL (28.2% of mean)) and peak‐velocity at peak systole (mean difference = −21.3 cm/s (17.2% of mean)) were underestimated by rt‐PC. This study demonstrates that the proposed rt‐PC with the said spatial resolution and temporal resolution produces relatively accurate forward volumes and regurgitant fractions but underestimates backward volumes and peak velocities at peak systole in pediatric patients with CHD.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (R01HL116895, R01HL138578)
- National Institute of Biomedical Imaging and Bioengineering (R21EB024315)
- National Institute on Aging (R21AG055954)
- National Institutes of Health (F30HL137279)
- American Heart Association (19IPLOI34760317)
This publication has 24 references indexed in Scilit:
- Optimization and validation of accelerated golden‐angle radial sparse MRI reconstruction with self‐calibrating GRAPPA operator griddingMagnetic Resonance in Medicine, 2017
- Real-time phase-contrast flow cardiovascular magnetic resonance with low-rank modeling and parallel imagingJournal of Cardiovascular Magnetic Resonance, 2016
- Real‐time flow MRI of the aorta at a resolution of 40 msecJournal of Magnetic Resonance Imaging, 2013
- A software channel compression technique for faster reconstruction with many channelsMagnetic Resonance Imaging, 2008
- An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRIIEEE Transactions on Medical Imaging, 2006
- Flow Volume and Shunt Quantification in Pediatric Congenital Heart Disease by Real-Time Magnetic Resonance Velocity MappingCirculation, 2004
- Centering the projection reconstruction trajectory: Reducing gradient delay errorsMagnetic Resonance in Medicine, 2003
- Adaptive reconstruction of phased array MR imageryMagnetic Resonance in Medicine, 2000
- Error in MR volumetric flow measurements due to ordered phase encoding in the presence of flow varying with respirationMagnetic Resonance in Medicine, 1995
- Pulmonary regurgitation in the late postoperative follow-up of tetralogy of Fallot. Volumetric quantitation by nuclear magnetic resonance velocity mapping.Circulation, 1993