In vitro investigation into the forces involved during lipofilling
Authors:
- 4 October 2018
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 232 (11) , 1111-1116
Abstract
Breast augmentation using implants is the most common aesthetic and reconstructive breast surgical procedure. Complications such as implant rupture maybe related to surgical technique and damage to the implant. Autologous fat transfer (lipofilling) using metallic cannulae has become a standard adjunctive, yet there is little evidence on lipofilling safety in the presence of implants. The aims of this study are to verify the effects of different cannulae and to quantify the forces applied by surgeons during lipofilling. Silicone gel-filled textured implants (200 mL), mounted on a specially constructed mould were ruptured with two different cannulae: type A (hole at tip: sharp) and type B (hole away from tip: blunt), driven at three speeds (10, 100 and 1000 mm/min), and the force at rupture was recorded. In addition, the maximum 10 forces over a 30-s period applied by 11 plastic surgeons against a breast implant in an in vitro environment were recorded using a load cell attached to a type-A cannula. Statistical analysis of comparative results was performed using t-tests, with p < 0.05 considered significant. Results showed that the implant ruptured at forces up to 25% lower when cannula A was used compared to cannula B. This supports current technique in lipofilling in the use of a blunt tipped cannula. There was a significant difference between some displacement rates only, due to the viscoelastic nature of the material. The tactile force that surgeons use during lipofilling was modelled in vitro and showed a range of maximum forces between 0.23 and 16.8 N, with a mean maximum value of 6.9 N. Limitation of this study is that it may not reflect in vivo behaviour of breast implants. More studies are needed to confirm the safety of breast lipofilling in the presence of implants using these data as a starting point.Keywords
This publication has 19 references indexed in Scilit:
- Failure of silicone gel breast implants: Is the mechanical weakening due to shell swelling a significant cause of prostheses rupture?Journal of the Mechanical Behavior of Biomedical Materials, 2011
- Fat Injection to the Breast: Technique, Results, and Indications Based on 880 Procedures Over 10 YearsAesthetic Surgery Journal, 2009
- Autologous fat transfer – a review of the literature with a focus on breast cancer surgeryJournal of Plastic, Reconstructive & Aesthetic Surgery, 2008
- Frequency dependence of viscoelastic properties of medical grade siliconesJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- Autologous fat transfer in reconstructive breast surgery: Indications, technique and resultsEuropean Journal of Surgical Oncology, 2007
- Mechanical Analysis of Explanted Silicone Breast ImplantsPlastic and Reconstructive Surgery, 1996
- Strength of Silicone Breast ImplantsPlastic and Reconstructive Surgery, 1996
- AUTOLOGOUS FAT TRANSPLANTATIONPlastic and Reconstructive Surgery, 1991
- Cosmetic Breast Augmentation Utilizing Autologous Fat and Liposuction TechniquesPlastic and Reconstructive Surgery, 1987
- THE FAT CELL “GRAFT”Plastic and Reconstructive Surgery, 1986