LLLaura Jane Leslie

Laura Jane Leslie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Laura Jane Leslie has a total of 48 co-authors. Here are the top co-authors by number of shared publications:

  • Kanthan Theivendran

    Trauma and Orthopaedics, Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, UK

    3 shared publications
  • Lindsay J. Marshall

    School of Life and Health Sciences, Aston University, Birmingham, UK

    3 shared publications
  • Pranav Vasanthi Bathrinarayanan

    Aston Institute of Materials Research, School of Engineering and Applied Science, Aston University, Birmingham B4 7ET, United Kingdom

    3 shared publications
  • Andrew Devitt

    Aston Institute for Membrane Excellence, School of Biosciences, College of Health and Life Sciences Aston University Birmingham UK

    2 shared publications
  • James E.P. Brown

    School of Life and Health Sciences, Aston University, Birmingham B4 7ET, United Kingdom; Aston Medical Research Institute, Aston University, Birmingham B4 7ET, United Kingdom

    2 shared publications
  • Lindsay J. Marshall

    Humane Society International, The Humane Society of the United States, 700 Professional Drive, Gaithersburg, MD 20879, USA

    2 shared publications

Latest Publications

  • Open Access

    Experimental testing of fracture fixation plates: A review

    by Shiling Zhang, Dharmesh Patel, Mark Brady, Sherri Gambill, Kanthan Theivendran, Subodh Deshmukh, John Swadener, Sarah Junaid, Laura Jane Leslie

    Metal and its alloys have been predominantly used in fracture fixation for centuries, but new materials such as composites and polymers have begun to see clinical use for fracture fixation during the past couple of decades. Along with the emerging of new materials, tribological issues, especially debris, have become a growing concern for fracture fixation plates. This article for the first time systematically reviews the most recent biomechanical research, with a focus on experimental testing, of those plates within ScienceDirect and PubMed databases. Based on the search criteria, a total of 5449 papers were retrieved, which were then further filtered to exclude nonrelevant, duplicate or non-accessible full article papers. In the end, a total of 83 papers were reviewed. In experimental testing plates, screws and simulated bones or cadaver bones are employed to build a fixation construct in order to test the strength and stability of different plate and screw configurations. The test set-up conditions and conclusions are well documented and summarised here, including fracture gap size, types of bones deployed, as well as the applied load, test speed and test ending criteria. However, research on long term plate usage was very limited. It is also discovered that there is very limited experimental research around the tribological behaviour particularly on the debris’ generation, collection and characterisation. In addition, there is no identified standard studying debris of fracture fixation plate. Therefore, the authors suggested the generation of a suite of tribological testing standards on fracture fixation plate and screws in the aim to answer key questions around the debris from fracture fixation plate of new materials or new design and ultimately to provide an insight on how to reduce the risks of debris-related osteolysis, inflammation and aseptic loosening.


  • Development of a Multi-Sensor Array for Non-Radiographic Micromotion Detection of Joint Prostheses

    by Muhammad Moid Khalid Khan, Subodh Deshmukh, Kanthan Theivendran, Laura Leslie, Sarah Junaid

    Total joint arthroplasty procedures are increasing year on year, however, the complications that are associated with the joint arthroplasty remain. Using total elbow arthroplasty as a case study due to the high loosening rates, a technique has been further developed to accurately monitor the position of the prosthesis. Micromotion detection of endoprosthetic elbow prostheses is vital for longevity along with timely, adequate treatment. At present, radiographs are used to monitor the prostheses position at the macro-scale which lacks in early detection of prostheses loosening. In this work, a multiple magnetic sensor (multi-sensor) configuration was designed that can detect real-time micromotion of the elbow prosthesis without the use of radiographs. The proposed approach can detect 0.15 mm micromotion with an average error below 0.05 mm linearly. This method also eliminated the tilting effect and increase the sensitivity of the system to 18 mm along with improving the signal to noise ratio and reducing RMS error compared to a single sensor configuration.


  • Open Access

    A New Diagnostic Technique to Detect Early Migration of Joint Prostheses

    by Muhammad Moid Khalid Khan, Subodh C. Deshmukh, Kanthan Theivendran, Laura J. Leslie, Sarah Junaid

    Migration of an implanted prosthesis due to aseptic loosening is difficult to detect without regular imaging. In this paper, a low-cost, non-radiographic, robust diagnostic technique is presented, which can detect the migration of the humeral component of an elbow prosthesis. The system consists of a single magnet single sensor configuration and migration data are based on the variation in the magnetic field. The magnetic sensor was enclosed in titanium alloy and a magnet was embedded at a reference point in the humeral bone enclosed in ultra-high molecular weight polyethylene (UHMWPE). A layer of bone cement was then placed between the enclosed magnet and sensor. An algorithm linked with a Savitzky- Golay (SG) filter was developed that could decouple, convert, and filter the magnetic field signal to provide both the linear and angular displacement. The system was also designed to eliminate the cross talk and non-linearity effect of the magnet. The highest resolution the sensor achieved was 0.3 mm with a detectable linear migration range of 0.3 mm to 4 mm in the x/y axis and between 8-20 mm in the z-axis (along the humeral canal). The detectable rotational range was 0.5 to 3.0 degrees in the x/y axis. The repeatability of the calibrated sensor was analysed and showed a standard deviation of 0.05 mm over 150 cycles. The resolution was dependent upon the operating conditions and sensor positioning. There was no interference from the titanium alloy, bone cement nor the UHMWPE. This sensor system offers an alternative non-radiographic option for measuring migration of implanted prostheses.


  • Thermally triggerable, anchoring block copolymers for use in aqueous inkjet printing

    by George E. Parkes, Helena J. Hutchins-Crawford, Claire Bourdin, Stuart Reynolds, Laura J. Leslie, Matthew J. Derry, Josephine L. Harries, Paul D. Topham

    Towards the goal of shifting from toxic organic solvents to aqueous-based formulations in commercial inkjet printing, a series of well-defined poly[(2-hydroxyethyl acrylate-stat-N-hydroxymethyl acrylamide)-block-propyl methacrylate], P[(HEA-st-HMAA)-b-PMA], amphiphilic block copolymers with varying degrees of polymerization and comonomer compositions were synthesized via reversible addition–fragmentation chain transfer (RAFT) polymerization. Optimized RAFT polymerization conditions were found to allow larger batch synthesis (>20 g scale) without compromise over molecular design control (molecular mass, hydrophobic/hydrophilic balance, dispersity, etc.). The copolymers were subsequently investigated for their crosslinking and adhesive properties, as well as jetting performance, to determine their suitability for use in aqueous ink formulations. Crosslinking was found to occur much faster for copolymers containing more of the crosslinkable HMAA monomer units and at higher molecular masses, allowing control over the required post-deposition processing time. The amphiphilic block copolymers synthesized herein demonstrate enhanced adhesive properties compared to a selection of commercial inks whilst also achieving high print quality and performance for use in aqueous continuous inkjet (CIJ) printing, which is a key step towards greener processes in the packaging industries, where printing onto hydrophobic substrates is needed.


  • Open Access

    Anaerobiosis influences virulence properties of Pseudomonas aeruginosa cystic fibrosis isolates and the interaction with Staphylococcus aureus

    by Ross Pallett, Laura J. Leslie, Peter. A. Lambert, Ivana Milic, Andrew Devitt, Lindsay J. Marshall

    The airways of individuals with cystic fibrosis (CF) are abundantly colonised by Staphylococcus aureus and Pseudomonas aeruginosa. Co-infecting hypoxic regions of static mucus within CF airways, together with decreases in pulmonary function, mucus plugging and oxygen consumption by host neutrophils gives rise to regions of anoxia. This study determined the impact of anaerobiosis upon S. aureus-P. aeruginosa interactions in planktonic co-culture and mixed species biofilms in vitro. Whilst anoxia reduced the ability for P. aeruginosa CF isolates to dominate over S. aureus, this occurred in an isolate dependent manner. Investigations into the underlying mechanisms suggest that the anti-staphylococcal compound facilitating P. aeruginosa dominance under normoxia and anoxia is greater than 3 kDa in size and is heat-stable. Not all interspecies interactions studied were antagonistic, as S. aureus exoproducts were shown to restore and enhance P. aeruginosa motility under normoxia and anoxia in an isolate dependent manner. Collectively, this study suggests changes in oxygen availability within regions of the CF lung is likely to influence interspecies interactions and in turn, potentially influence disease progression.


  • In vitro investigation into the forces involved during lipofilling

    by Laura J Leslie, Yezen Sheena, Duncan Et Shepherd, Amir Ismail, Stephen N Kukureka, Vik Vijh

    Breast augmentation using implants is the most common aesthetic and reconstructive breast surgical procedure. Complications such as implant rupture maybe related to surgical technique and damage to the implant. Autologous fat transfer (lipofilling) using metallic cannulae has become a standard adjunctive, yet there is little evidence on lipofilling safety in the presence of implants. The aims of this study are to verify the effects of different cannulae and to quantify the forces applied by surgeons during lipofilling. Silicone gel-filled textured implants (200 mL), mounted on a specially constructed mould were ruptured with two different cannulae: type A (hole at tip: sharp) and type B (hole away from tip: blunt), driven at three speeds (10, 100 and 1000 mm/min), and the force at rupture was recorded. In addition, the maximum 10 forces over a 30-s period applied by 11 plastic surgeons against a breast implant in an in vitro environment were recorded using a load cell attached to a type-A cannula. Statistical analysis of comparative results was performed using t-tests, with p < 0.05 considered significant. Results showed that the implant ruptured at forces up to 25% lower when cannula A was used compared to cannula B. This supports current technique in lipofilling in the use of a blunt tipped cannula. There was a significant difference between some displacement rates only, due to the viscoelastic nature of the material. The tactile force that surgeons use during lipofilling was modelled in vitro and showed a range of maximum forces between 0.23 and 16.8 N, with a mean maximum value of 6.9 N. Limitation of this study is that it may not reflect in vivo behaviour of breast implants. More studies are needed to confirm the safety of breast lipofilling in the presence of implants using these data as a starting point.


  • An investigation into E-cigarette cytotoxicity in-vitro using a novel 3D differentiated co-culture model of human airways

    by Pranav Vasanthi Bathrinarayanan, James E.P. Brown, Lindsay J. Marshall, Laura J. Leslie


  • Using three-dimensional rapid prototyping in the design and development of orthopaedic screws in standardised pull-out tests

    by Laura Jane Leslie, Ashley Connolly, John G Swadener, Sarah Junaid, Kanthan Theivendran, Subodh C Deshmukh

    The majority of orthopaedic screws are designed, tested and manufactured by existing orthopaedics companies and are predominantly developed with healthy bone in mind. The timescales and costs involved in the development of a new screw design, for example, for osteoporotic bone, are high. In this study, standard wood screws were used to analyse the concept of using three-dimensional printing, or rapid prototyping, as a viable stage of development in the design of a new bone screw. Six wood screws were reverse engineered and printed in polymeric material using stereolithography. Three of the designs were also printed in Ti6Al4V using direct metal laser sintering; however, these were not of sufficient quality to test further. Both the original metal screws (metal) and polymeric rapid prototyping screws were then tested using standard pull-out tests from low-density polyurethane blocks (Sawbones). Results showed the highest pull-out strengths for screws with the longest thread length and the smallest inner diameter. Of the six screw designs tested, five showed no more than a 17% variance between the metal and rapid prototyping results. A similar pattern of results was shown between the screw designs for both the metal and rapid prototyping screws in five of the six cases. While not producing fully comparable pull-out results to orthopaedic screws, the results from this study do provide evidence of the potential usefulness and cost-effectiveness of rapid prototyping in the early stages of design and testing of orthopaedic screws.


  • An investigation into the effects of E-cigarette aerosols using a physiologically relevant in-vitro model

    by Pranav Vasanthi Bathrinarayanan, Lindsay J. Marshall, James E.P. Brown, Laura J. Leslie