Long-term stability of metal-envelope enclosed Bayard–Alpert ionization gauges
- 12 September 2012
- journal article
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 30 (6) , 061601
Abstract
Ionization vacuum gauges are used as secondary standards by calibration laboratories and as transfer standards in intercomparisons among metrology laboratories. A quantitative measurement of gauge stability with respect to the gauge calibration factor is critical for these applications. We report the long-term calibration stability of hot-filament metal-envelope enclosed ionization gauges based upon the analysis of repeat calibrations of nine gauges over a 15 year period. All of the gauges included in the study were of the same type: Bayard–Alpert type ionization gauges of an all-metal construction with an integral metal-envelope surrounding the hot-filament, grid, and collector. All were calibrated repeatedly at the National Institute of Standards and Technology (NIST) using the NIST high-vacuum standard but are owned by organizations external to NIST. The gauges were removed from the high-vacuum standard after calibration, shipped back to the gauge-owner, and were returned to NIST at a later date (more than 1 year) for recalibration. Gauge stability was determined using a pooled standard deviation (weighted root-mean-square average of individual gauge standard deviations) based on all calibration factors measured at NIST and was used to define the relative uncertainty component associated with long-term stability uLTS. We determined uLTS = 1.9% (k = 1) for gauges operated with 4 mA of emission current, and uLTS = 2.8% (k = 1) for gauges operated with 0.1 mA emission current.Keywords
This publication has 20 references indexed in Scilit:
- Final report of key comparison CCM.P-K3: absolute pressure measurements in gas from 3 × 10−6Pa to 9 × 10−4PaMetrologia, 2010
- Stable and reproducible Bayard–Alpert ionization gaugeJournal of Vacuum Science & Technology A, 1994
- Causes of nonstability and nonreproducibility in widely used Bayard–Alpert ionization gaugesJournal of Vacuum Science & Technology A, 1994
- Nonstable behavior of widely used ionization gaugesJournal of Vacuum Science & Technology A, 1994
- Search for pressure dependence in the sensitivity of several common types of hot-cathode ionization gauges for total pressures down to 10−7 PaJournal of Vacuum Science & Technology A, 1991
- Low pressure limit of the bayard-alpert gaugeNuclear Instruments and Methods, 1977
- Electron trajectories in ionization gaugesJournal of Physics D: Applied Physics, 1970
- The Sensitivity of Bayard–Alpert GaugesJournal of Vacuum Science and Technology, 1969
- New Hot-Filament Ionization Gauge with Low Residual CurrentJournal of Vacuum Science and Technology, 1966
- Ion Collection in the Bayard-Alpert GaugeJournal of Applied Physics, 1966