James A. Fedchak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
James A. Fedchak has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Julia Scherschligt
National Institute of Standards and Technology
12 shared publications - Daniel S. Barker
National Institute of Standards and Technology
10 shared publications - Stephen Eckel
National Institute of Standards and Technology
9 shared publications - Eite Tiesinga
Joint Quantum Institute
4 shared publications Makfir Sefa
National Institute of Standards and Technology , Gaithersburg, Maryland 20899
4 shared publicationsJulia Scherschligt
National Institute of Standards and Technology 100 Bureau Drive 20899-8364 Gaithersburg MD USA
3 shared publications
Latest Publications
- 12 February 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 111 (2)
Effect of glancing collisions in the cold-atom vacuum standard
We theoretically investigate the effect of "glancing" collisions on the ultra-high vacuum (UHV) pressure readings of the cold atom vacuum standard (CAVS), based on either ultracold 7Li or 87Rb atoms. Here, glancing collisions are those collisions between ultracold atoms and room-temperature background atoms or molecules in the vacuum that do not impart enough kinetic energy to eject an ultracold atom from its trap. Our model is wholly probabilistic and shows that the number of the ultracold atoms remaining in the trap as a function of time is non-exponential. We update the recent results of a comparison between a traditional pressure standard-a combined flowmeter and dynamic expansion system-to the CAVS [D.S. Barker, et al., AVS Quantum Science 5 035001 (2023)] to reflect the results of our model. We find that the effect of glancing collisions shifts the theoretical predictions of the total loss rate coefficients for 7Li colliding with noble gases or N2 by up to 0.6 %. Likewise, we find that in the limit of zero trap depth the experimentally extracted loss rate coefficients for 87Rb colliding with noble gases or N2 shift by as much as 2.2 %.
- 12 February 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 111 (2)
Effect of glancing collisions in the cold-atom vacuum standard
We theoretically investigate the effect of "glancing" collisions on the ultra-high vacuum (UHV) pressure readings of the cold atom vacuum standard (CAVS), based on either ultracold 7Li or 87Rb atoms. Here, glancing collisions are those collisions between ultracold atoms and room-temperature background atoms or molecules in the vacuum that do not impart enough kinetic energy to eject an ultracold atom from its trap. Our model is wholly probabilistic and shows that the number of the ultracold atoms remaining in the trap as a function of time is non-exponential. We update the recent results of a comparison between a traditional pressure standard-a combined flowmeter and dynamic expansion system-to the CAVS [D.S. Barker, et al., AVS Quantum Science 5 035001 (2023)] to reflect the results of our model. We find that the effect of glancing collisions shifts the theoretical predictions of the total loss rate coefficients for 7Li colliding with noble gases or N2 by up to 0.6 %. Likewise, we find that in the limit of zero trap depth the experimentally extracted loss rate coefficients for 87Rb colliding with noble gases or N2 shift by as much as 2.2 %.
- Open Access
- 1 August 2023
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 5 (3)
Accurate measurement of the loss rate of cold atoms due to background gas collisions for the quantum-based cold atom vacuum standard
We present the measurements of thermalized collisional rate coefficients for ultra-cold 7Li and 87Rb colliding with room-temperature He, Ne, N2, Ar, Kr, and Xe. In our experiments, a combined flowmeter and dynamic expansion system, a vacuum metrology standard, is used to set a known number density for the room-temperature background gas in the vicinity of the magnetically trapped 7Li or 87Rb clouds. Each collision with a background atom or molecule removes a 7Li or 87Rb atom from its trap, and the change in the atom loss rate with background gas density is used to determine the thermalized loss rate coefficients with fractional standard uncertainties better than 1.6% for 7Li and 2.7% for 87Rb. We find consistency—a degree of equivalence of less than one—between the measurements and recent quantum-scattering calculations of the loss rate coefficients [Kłos and Tiesinga, J. Chem. Phys. 158, 014308 (2023)], with the exception of the loss rate coefficient for both 7Li and 87Rb colliding with Ar. Nevertheless, the agreement between theory and experiment for all other studied systems provides validation that a quantum-based measurement of vacuum pressure using cold atoms also serves as a primary standard for vacuum pressure, which we refer to as the cold-atom vacuum standard.
- 1 August 2023
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 5 (3)
Open AccessAccurate measurement of the loss rate of cold atoms due to background gas collisions for the quantum-based cold atom vacuum standard
We present the measurements of thermalized collisional rate coefficients for ultra-cold 7Li and 87Rb colliding with room-temperature He, Ne, N2, Ar, Kr, and Xe. In our experiments, a combined flowmeter and dynamic expansion system, a vacuum metrology standard, is used to set a known number density for the room-temperature background gas in the vicinity of the magnetically trapped 7Li or 87Rb clouds. Each collision with a background atom or molecule removes a 7Li or 87Rb atom from its trap, and the change in the atom loss rate with background gas density is used to determine the thermalized loss rate coefficients with fractional standard uncertainties better than 1.6% for 7Li and 2.7% for 87Rb. We find consistency—a degree of equivalence of less than one—between the measurements and recent quantum-scattering calculations of the loss rate coefficients [Kłos and Tiesinga, J. Chem. Phys. 158, 014308 (2023)], with the exception of the loss rate coefficient for both 7Li and 87Rb colliding with Ar. Nevertheless, the agreement between theory and experiment for all other studied systems provides validation that a quantum-based measurement of vacuum pressure using cold atoms also serves as a primary standard for vacuum pressure, which we refer to as the cold-atom vacuum standard.
- Open Access
- 1 December 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (12) , 121101
Precise quantum measurement of vacuum with cold atoms
We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard–Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.
- 1 December 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (12) , 121101
Open AccessPrecise quantum measurement of vacuum with cold atoms
We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard–Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.
- 15 July 2022
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 4 (3) , 034403
Comparison of two multiplexed portable cold-atom vacuum standards
We compare the vacuum measured by two portable cold-atom vacuum standards (pCAVSs) based on ultracold 7Li atoms. pCAVSs are quantum-based standards that use a priori scattering calculations to convert a measured loss rate of cold atoms from a conservative trap into a background gas pressure. Our pCAVS devices share the same laser system and measure the vacuum concurrently. The two pCAVSs together detected a leak with a rate on the order of 10−6 Pa l/s. After fixing the leak, the pCAVS measured pressure of about 40 nPa with 2.6% uncertainty. The two pCAVSs agree within their uncertainties, even when swapping some of their component parts. Operation of the pCAVS was found to cause some additional outgassing, on the order of 10−8 Pa l/s, which can be mitigated in the future by better thermal management.
- 15 July 2022
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 4 (3) , 034403
Comparison of two multiplexed portable cold-atom vacuum standards
We compare the vacuum measured by two portable cold-atom vacuum standards (pCAVSs) based on ultracold 7Li atoms. pCAVSs are quantum-based standards that use a priori scattering calculations to convert a measured loss rate of cold atoms from a conservative trap into a background gas pressure. Our pCAVS devices share the same laser system and measure the vacuum concurrently. The two pCAVSs together detected a leak with a rate on the order of 10−6 Pa l/s. After fixing the leak, the pCAVS measured pressure of about 40 nPa with 2.6% uncertainty. The two pCAVSs agree within their uncertainties, even when swapping some of their component parts. Operation of the pCAVS was found to cause some additional outgassing, on the order of 10−8 Pa l/s, which can be mitigated in the future by better thermal management.
- 25 May 2022
- Published by Morressier GmbH
Validation of the cold atom vacuum standard
Validation of the cold atom vacuum standard |
- 25 May 2022
- Published by Morressier GmbH
Validation of the cold atom vacuum standard
Validation of the cold atom vacuum standard |
- 1 March 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (3) , 033201
A Bitter-type electromagnet for complex atomic trapping and manipulation
We create a pair of symmetric Bitter-type electromagnet assemblies capable of producing multiple field configurations including uniform magnetic fields, spherical quadruple traps, or Ioffe–Pritchard magnetic bottles. Unlike other designs, our coil allows both radial and azimuthal cooling water flows by incorporating an innovative 3D-printed water distribution manifold. Combined with a double-coil geometry, such orthogonal flows permit stacking of non-concentric Bitter coils. We achieve a low thermal resistance of 4.2(1) °C kW−1 and high water flow rate of 10.0(3) l min−1 at a pressure of 190(10) kPa.
- 1 March 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (3) , 033201
A Bitter-type electromagnet for complex atomic trapping and manipulation
We create a pair of symmetric Bitter-type electromagnet assemblies capable of producing multiple field configurations including uniform magnetic fields, spherical quadruple traps, or Ioffe–Pritchard magnetic bottles. Unlike other designs, our coil allows both radial and azimuthal cooling water flows by incorporating an innovative 3D-printed water distribution manifold. Combined with a double-coil geometry, such orthogonal flows permit stacking of non-concentric Bitter coils. We achieve a low thermal resistance of 4.2(1) °C kW−1 and high water flow rate of 10.0(3) l min−1 at a pressure of 190(10) kPa.
- 23 February 2021
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 39 (2) , 024201
Outgassing rate comparison of seven geometrically similar vacuum chambers of different materials and heat treatments
We have measured the water and hydrogen outgassing rates of seven vacuum chambers of identical geometry but constructed of different materials and heat treatments. Chambers of five different materials were tested: 304L, 316L, and 316LN stainless steels; titanium (ASTM grade 2); and 6061 aluminum. In addition, chambers constructed of 316L and 316LN stainless steel were subjected to a vacuum-fire process, where they were heated to approximately 950 °C for 24 h while under vacuum. These latter two chambers are designated as 316L-XHV and 316LN-XHV. Because all the chambers were of identical geometry and made by the same manufacturer, a relative comparison of the outgassing rates among these chambers can be made. Water outgassing rates were measured as a function of time using the throughput technique. The water outgassing results for 316L, 316LN, 316L-XHV, and 316LN-XHV were all similar but lower than those for 304L by a factor of 3–5 lower at 104 s. The water outgassing results for the Ti and Al chambers were closer to that of 304L, Ti being slightly lower. Hydrogen outgassing rates were measured using the rate-of-rise method and performed after a low-temperature bake of 125–150 °C for a minimum of 72 h. The Ti, Al, 316L-XHV, and 316LN-XHV chambers all have ultralow specific outgassing rates below 1 × 10−11 Pa l s−1 cm−2 and are a factor of 100 or better than the 304L chamber. The 304L, 316L, and 316LN chambers with no vacuum-fire heat treatment have larger hydrogen outgassing rates than the other chambers, with determined specific outgassing rates ranging between 4.0 and 8.0 × 10−11 Pa l s−1 cm−2. We conclude that Ti, Al, 316L-XHV, and 316LN-XHV have hydrogen outgassing rates that make them excellent choices for ultrahigh vacuum and extreme-high vacuum applications, the choice depending on cost and other material properties.
- 23 February 2021
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 39 (2) , 024201
Outgassing rate comparison of seven geometrically similar vacuum chambers of different materials and heat treatments
We have measured the water and hydrogen outgassing rates of seven vacuum chambers of identical geometry but constructed of different materials and heat treatments. Chambers of five different materials were tested: 304L, 316L, and 316LN stainless steels; titanium (ASTM grade 2); and 6061 aluminum. In addition, chambers constructed of 316L and 316LN stainless steel were subjected to a vacuum-fire process, where they were heated to approximately 950 °C for 24 h while under vacuum. These latter two chambers are designated as 316L-XHV and 316LN-XHV. Because all the chambers were of identical geometry and made by the same manufacturer, a relative comparison of the outgassing rates among these chambers can be made. Water outgassing rates were measured as a function of time using the throughput technique. The water outgassing results for 316L, 316LN, 316L-XHV, and 316LN-XHV were all similar but lower than those for 304L by a factor of 3–5 lower at 104 s. The water outgassing results for the Ti and Al chambers were closer to that of 304L, Ti being slightly lower. Hydrogen outgassing rates were measured using the rate-of-rise method and performed after a low-temperature bake of 125–150 °C for a minimum of 72 h. The Ti, Al, 316L-XHV, and 316LN-XHV chambers all have ultralow specific outgassing rates below 1 × 10−11 Pa l s−1 cm−2 and are a factor of 100 or better than the 304L chamber. The 304L, 316L, and 316LN chambers with no vacuum-fire heat treatment have larger hydrogen outgassing rates than the other chambers, with determined specific outgassing rates ranging between 4.0 and 8.0 × 10−11 Pa l s−1 cm−2. We conclude that Ti, Al, 316L-XHV, and 316LN-XHV have hydrogen outgassing rates that make them excellent choices for ultrahigh vacuum and extreme-high vacuum applications, the choice depending on cost and other material properties.
- 1 October 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (10) , 104708
A radiofrequency voltage-controlled current source for quantum spin manipulation
We present a wide-bandwidth, voltage-controlled current source that is easily integrated with radiofrequency magnetic field coils. Our design uses current feedback to compensate for the frequency-dependent impedance of a radiofrequency antenna. We are able to deliver peak currents greater than 100 mA over a 300 kHz to 54 MHz frequency span. The radiofrequency current source fits onto a printed circuit board smaller than 4 cm2 and consumes less than 1.3 W of power. It is suitable for use in deployable quantum sensors and nuclear magnetic resonance systems.
- 1 October 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (10) , 104708
A radiofrequency voltage-controlled current source for quantum spin manipulation
We present a wide-bandwidth, voltage-controlled current source that is easily integrated with radiofrequency magnetic field coils. Our design uses current feedback to compensate for the frequency-dependent impedance of a radiofrequency antenna. We are able to deliver peak currents greater than 100 mA over a 300 kHz to 54 MHz frequency span. The radiofrequency current source fits onto a printed circuit board smaller than 4 cm2 and consumes less than 1.3 W of power. It is suitable for use in deployable quantum sensors and nuclear magnetic resonance systems.
- Open Access
- 3 July 2019
- Published by Springer Nature in Communications Physics
- Vol. 2 (1) , 1-6
Nuclear-spin dependent parity violation in optically trapped polyatomic molecules
Improved nuclear spin-dependent parity violation measurements will enable experimental determination of poorly known electroweak coupling parameters. Here, we investigate the suitability of optically trapped linear polyatomic molecules as probes of nuclear spin-dependent parity violation. The presence of closely spaced, opposite-parity $$\ell$$ -doublets is a general feature of such molecules, allowing parity-violation-sensitive pairs of levels to be brought to degeneracy in magnetic fields typically 100 times smaller than in diatomics. Assuming laser cooling and trapping of polyatomics at the current state-of-the-art for diatomics, we expect to measure nuclear spin-dependent parity-violating matrix elements iW with 70 times better sensitivity than the current best measurements. Our scheme should allow for 10% measurements of iW in nuclei as light as Be or as heavy as Yb, with averaging times on the order of 10 days and 1 s, respectively.- 3 July 2019
- Published by Springer Nature in Communications Physics
- Vol. 2 (1) , 1-6
Open AccessNuclear-spin dependent parity violation in optically trapped polyatomic molecules
Improved nuclear spin-dependent parity violation measurements will enable experimental determination of poorly known electroweak coupling parameters. Here, we investigate the suitability of optically trapped linear polyatomic molecules as probes of nuclear spin-dependent parity violation. The presence of closely spaced, opposite-parity $$\ell$$ -doublets is a general feature of such molecules, allowing parity-violation-sensitive pairs of levels to be brought to degeneracy in magnetic fields typically 100 times smaller than in diatomics. Assuming laser cooling and trapping of polyatomics at the current state-of-the-art for diatomics, we expect to measure nuclear spin-dependent parity-violating matrix elements iW with 70 times better sensitivity than the current best measurements. Our scheme should allow for 10% measurements of iW in nuclei as light as Be or as heavy as Yb, with averaging times on the order of 10 days and 1 s, respectively. - Open Access
- 27 April 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 36 (3)
Review Article: Recommended practice for calibrating vacuum gauges of the ionization type
This article represents a recommended practice for the calibration of ionization gauges usig the comparison method. In this method, ionization gauges are compared to a working standard that has a système international, or the international system of units traceable calibration. The ionization gauge is either of the hot-cathode ionization type or the cold-cathode ionization type. Details of the calibration apparatus, the principle of operation of the gauges, data analysis, uncertainty budget, and reporting the uncertainty are given.
- 27 April 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 36 (3)
Open AccessReview Article: Recommended practice for calibrating vacuum gauges of the ionization type
This article represents a recommended practice for the calibration of ionization gauges usig the comparison method. In this method, ionization gauges are compared to a working standard that has a système international, or the international system of units traceable calibration. The ionization gauge is either of the hot-cathode ionization type or the cold-cathode ionization type. Details of the calibration apparatus, the principle of operation of the gauges, data analysis, uncertainty budget, and reporting the uncertainty are given.