Development of an algorithm for effective design of respirator half-masks and encapsulated particle filters
- 25 February 2021
- journal article
- research article
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 28 (2) , 1145-1159
Abstract
Introduction: The social and economic situation in modern world requires new approaches to the development of respiratory protective equipment. Objective: Improve the process of 3D modeling of respirator half-masks and encapsulated particle filters to them. Methods: The basic provisions of the theory of non-stationary filtration and hydroaerodynamics; the Nelder-Mead method; the linear interpolation equation. Results: The peculiarity of the algorithm is the adjustment stage of the design process aimed at efficiency check for half-mask. The surface of the half mask was constructed according to the coordinates of the 3D model of a worker's head. Conclusion: For the first time the regularities of algorithm for design of the half-mask surface of dust respirators were defined based on the data of three-dimensional coordinates of key points of anthropometric parameters of the workers' faces. The pressure difference on the encapsulated particle filters of dust respirators is determined by the particle filter’s resistance coefficient and the air flow through them, the diameters ratio of their outlets and inlets. Relevance to industry: The algorithm developed provides the product verification at the design stage using criteria evaluation of the parameters of the polygonal model of the head; preliminary calculation of the protection factor; checking the tightness of the prototype.Keywords
This publication has 19 references indexed in Scilit:
- Headform and N95 Filtering Facepiece Respirator Interaction: Contact Pressure Simulation and ValidationJournal of Occupational and Environmental Hygiene, 2012
- Objective Assessment of Increase in Breathing Resistance of N95 Respirators on Human SubjectsAnnals of Work Exposures and Health, 2011
- Fit Testing Respirators for Public Health Medical EmergenciesJournal of Occupational and Environmental Hygiene, 2010
- The Effect of Gender and Respirator Brand on the Association of Respirator Fit with Facial DimensionsJournal of Occupational and Environmental Hygiene, 2007
- Preparation and characterization of stable chitosan nanofibrous membrane for lipase immobilizationEuropean Polymer Journal, 2007
- New Respirator Fit Test Panels Representing the Current U.S. Civilian Work ForceJournal of Occupational and Environmental Hygiene, 2007
- Three-dimensional recording of the human face with a 3D laser scannerJournal of Plastic, Reconstructive & Aesthetic Surgery, 2006
- The Effect of Pressure Drop on Respirator Faceseal LeakageJournal of Occupational and Environmental Hygiene, 2005
- Estimating Service Lives of Organic Vapor Cartridges II: A Single Vapor at All HumiditiesJournal of Occupational and Environmental Hygiene, 2004
- A MATHEMATICAL STUDY OF AEROSOL SAMPLING BY AN IDEALISED BLUNT SAMPLER ORIENTED AT AN ANGLE TO THE WIND: THE ROLE OF GRAVITYJournal of Aerosol Science, 2000