Experimental Study on Evaluation of Replacing Minimum Web Reinforcement with Discrete Fibers in RC Deep Beams
Open Access
Abstract
This study investigates the possibility of replacing the minimum web reinforcement in deep beams with discrete fibers. Additionally, the equivalent dosage of fibers required to obtain similar performance of the deep beam with minimum web reinforcement is investigated. Deep beams made of plain concrete with no fibers, beams with minimum web reinforcement as per AASHTO LFRD recommendations (0.3% in both horizontal and vertical), and with a 0.5% volume fraction of steel, macro-synthetic and hybrid fibers are tested at a shear span to height ratio (a/h) of one. Test results show that the presence of 0.3% web reinforcement in horizontal and vertical directions increased the peak load by 25% compared to the plain concrete beams. However, it did not significantly change the first diagonal crack load. With the addition of 0.5% of steel, macro-synthetic and hybrid fibers, the peak load increased by 49%, 42%, and 63%, respectively, compared to the plain concrete specimen. The addition of steel fibers significantly improved the first cracking load. In contrast, macro-synthetic fibers did not affect the first cracking load but improved the ductility with higher deflections at peak. Hybridization of steel and macro synthetic fibers showed improved performance compared to the individual fibers of the same volume in peak load and ductility. Test results showed that a 0.5% volume fraction of discrete macro steel or synthetic or hybrid fibers can be used to completely replace the minimum web reinforcement (0.3% in both directions).Keywords
This publication has 51 references indexed in Scilit:
- Fiber distribution and orientation in UHP-FRC beams and their effect on backward analysisMaterials and Structures, 2013
- Flexural performance of fibre reinforced concrete made with steel and synthetic fibresConstruction and Building Materials, 2012
- Influence of yield stress and compressive strength on direct shear behaviour of steel fibre-reinforced concreteConstruction and Building Materials, 2012
- Post-cracking behaviour of steel and macro-synthetic fibre-reinforced concretesConstruction and Building Materials, 2011
- New formula for the estimation of shear resistance of fibre reinforced beamsCanadian Journal of Civil Engineering, 2011
- An appraisal of the ACI strut efficiency factorsMagazine of Concrete Research, 2009
- Cohesive Crack Model and Fracture Energy of Steel-Fiber-Reinforced-Concrete Notched Cylindrical SpecimensJournal of Materials in Civil Engineering, 2007
- Effectiveness of stirrups and steel fibres as shear reinforcementCement and Concrete Composites, 2004
- Shear characteristics of high-strength concrete deep beams without shear reinforcementsEngineering Structures, 2003
- Behaviour of fibre reinforced concrete deep beamsCement and Concrete Composites, 1990