Chandrashekhar Lakavath
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chandrashekhar Lakavath has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Shanmugam Suriya Prakash
Department of Civil Engineering Indian Institute of Technology Hyderabad Sangareddy India
5 shared publications S. Suriya Prakash
3 shared publications- Akanshu Sharma
Lyles School of Civil and Construction Engineering Purdue University West Lafayette Indiana USA
2 shared publications - Aniket B. Bhosale
Department of Civil Engineering, Indian Institute of Technology Hyderabad, Sangareddy 502285, India
2 shared publications Aniket B. Bhosale
1 shared publication- B. Kondraivendhan
Department of Civil Engineering, Sardar Vallabhbhai National Institute of Technology, Surat, India
1 shared publication
Latest Publications
- Open Access
Effectiveness of Hybrid Fibers on the Fracture and Shear Behavior of Prestressed Concrete Beams
This study investigates the effectiveness of hybrid fibers (steel and macro-synthetic) on the shear behavior of prestressed concrete beams. The hybrid fiber combination was selected to avoid workability issues at high volume dosages and ensure effective crack arresting over the crack opening range. Fracture studies included testing notched concrete prisms to identify the role of hybrid fibers in the crack bridging mechanism. Seven hybrid fiber reinforced prestressed concrete (HFRPC) beams were tested at a low shear span (a) to depth (d) ratio of 2.4. The effects of hybrid fibers on load–deflection behavior and strain in the strand are reported. Similarly, the crack opening, crack slip and crack angle variation regarding applied shear were investigated using the digital image correlation (DIC) technique. Test results of HFRPC beams showed considerable improvements in peak load and the post-peak response with a higher hybrid fiber dosage. The crack opening and crack slip measurement across the major shear crack revealed continuous dilatant behavior. The kinematic response of critical shear crack reflects the sustained dilation response up to the ultimate load, which depends on the critical shear crack angle of the tested beams. As the fiber dosage increases, the shear crack slip and width are reduced, indicating the roles of hybrid fibers in improving ductility and the change in failure mode from brittle shear tension to relatively ductile shear tension.
Open AccessEffectiveness of Hybrid Fibers on the Fracture and Shear Behavior of Prestressed Concrete Beams
This study investigates the effectiveness of hybrid fibers (steel and macro-synthetic) on the shear behavior of prestressed concrete beams. The hybrid fiber combination was selected to avoid workability issues at high volume dosages and ensure effective crack arresting over the crack opening range. Fracture studies included testing notched concrete prisms to identify the role of hybrid fibers in the crack bridging mechanism. Seven hybrid fiber reinforced prestressed concrete (HFRPC) beams were tested at a low shear span (a) to depth (d) ratio of 2.4. The effects of hybrid fibers on load–deflection behavior and strain in the strand are reported. Similarly, the crack opening, crack slip and crack angle variation regarding applied shear were investigated using the digital image correlation (DIC) technique. Test results of HFRPC beams showed considerable improvements in peak load and the post-peak response with a higher hybrid fiber dosage. The crack opening and crack slip measurement across the major shear crack revealed continuous dilatant behavior. The kinematic response of critical shear crack reflects the sustained dilation response up to the ultimate load, which depends on the critical shear crack angle of the tested beams. As the fiber dosage increases, the shear crack slip and width are reduced, indicating the roles of hybrid fibers in improving ductility and the change in failure mode from brittle shear tension to relatively ductile shear tension.
- Open Access
Experimental Study on Evaluation of Replacing Minimum Web Reinforcement with Discrete Fibers in RC Deep Beams
This study investigates the possibility of replacing the minimum web reinforcement in deep beams with discrete fibers. Additionally, the equivalent dosage of fibers required to obtain similar performance of the deep beam with minimum web reinforcement is investigated. Deep beams made of plain concrete with no fibers, beams with minimum web reinforcement as per AASHTO LFRD recommendations (0.3% in both horizontal and vertical), and with a 0.5% volume fraction of steel, macro-synthetic and hybrid fibers are tested at a shear span to height ratio (a/h) of one. Test results show that the presence of 0.3% web reinforcement in horizontal and vertical directions increased the peak load by 25% compared to the plain concrete beams. However, it did not significantly change the first diagonal crack load. With the addition of 0.5% of steel, macro-synthetic and hybrid fibers, the peak load increased by 49%, 42%, and 63%, respectively, compared to the plain concrete specimen. The addition of steel fibers significantly improved the first cracking load. In contrast, macro-synthetic fibers did not affect the first cracking load but improved the ductility with higher deflections at peak. Hybridization of steel and macro synthetic fibers showed improved performance compared to the individual fibers of the same volume in peak load and ductility. Test results showed that a 0.5% volume fraction of discrete macro steel or synthetic or hybrid fibers can be used to completely replace the minimum web reinforcement (0.3% in both directions).
Open AccessExperimental Study on Evaluation of Replacing Minimum Web Reinforcement with Discrete Fibers in RC Deep Beams
This study investigates the possibility of replacing the minimum web reinforcement in deep beams with discrete fibers. Additionally, the equivalent dosage of fibers required to obtain similar performance of the deep beam with minimum web reinforcement is investigated. Deep beams made of plain concrete with no fibers, beams with minimum web reinforcement as per AASHTO LFRD recommendations (0.3% in both horizontal and vertical), and with a 0.5% volume fraction of steel, macro-synthetic and hybrid fibers are tested at a shear span to height ratio (a/h) of one. Test results show that the presence of 0.3% web reinforcement in horizontal and vertical directions increased the peak load by 25% compared to the plain concrete beams. However, it did not significantly change the first diagonal crack load. With the addition of 0.5% of steel, macro-synthetic and hybrid fibers, the peak load increased by 49%, 42%, and 63%, respectively, compared to the plain concrete specimen. The addition of steel fibers significantly improved the first cracking load. In contrast, macro-synthetic fibers did not affect the first cracking load but improved the ductility with higher deflections at peak. Hybridization of steel and macro synthetic fibers showed improved performance compared to the individual fibers of the same volume in peak load and ductility. Test results showed that a 0.5% volume fraction of discrete macro steel or synthetic or hybrid fibers can be used to completely replace the minimum web reinforcement (0.3% in both directions).
- 1 May 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 33 (5) , 04021074
Experimental and Analytical Studies on Fracture Behavior of Fiber-Reinforced Structural Lightweight Aggregate Concrete
This study presents the fracture behavior of synthetic fiber-reinforced structural lightweight aggregate concrete (SynFR-SLWAC) by experimental and analytical studies. Experimental studies include testing of 15 specimens for understanding mode-1 fracture response. Analytical studies include developing multilinear stress-crack width relations through inverse analysis. SynFR-SLWAC is made using sintered fly ash aggregate (SFA) with varying volume fractions of monofilament macro synthetic (0.2%, 0.4%, and 0.6%) and a small fraction of micro synthetic fibers (0.02%). The effect of synthetic fiber addition on the crack arresting mechanisms of SynFR-SLWAC is studied using the digital image correlation (DIC) technique. The stress-crack width relations are obtained from the experimental load-crack mouth opening displacement (CMOD) curves using inverse analysis. Additionally, empirical equations are proposed for predicting the stress-crack width relationship for SynFR-SLWAC with different fiber volume fractions. Fracture energy increased significantly with an increase in fiber volume dosage at larger values of crack width. Hinge width of SynFR-SLWAC reduced when compared to normal density concrete made of natural coarse aggregates.
- 1 May 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 33 (5) , 04021074
Experimental and Analytical Studies on Fracture Behavior of Fiber-Reinforced Structural Lightweight Aggregate Concrete
This study presents the fracture behavior of synthetic fiber-reinforced structural lightweight aggregate concrete (SynFR-SLWAC) by experimental and analytical studies. Experimental studies include testing of 15 specimens for understanding mode-1 fracture response. Analytical studies include developing multilinear stress-crack width relations through inverse analysis. SynFR-SLWAC is made using sintered fly ash aggregate (SFA) with varying volume fractions of monofilament macro synthetic (0.2%, 0.4%, and 0.6%) and a small fraction of micro synthetic fibers (0.02%). The effect of synthetic fiber addition on the crack arresting mechanisms of SynFR-SLWAC is studied using the digital image correlation (DIC) technique. The stress-crack width relations are obtained from the experimental load-crack mouth opening displacement (CMOD) curves using inverse analysis. Additionally, empirical equations are proposed for predicting the stress-crack width relationship for SynFR-SLWAC with different fiber volume fractions. Fracture energy increased significantly with an increase in fiber volume dosage at larger values of crack width. Hinge width of SynFR-SLWAC reduced when compared to normal density concrete made of natural coarse aggregates.
- 31 December 2018
- Published by Springer Nature
- p. 781-792
Experimental and Numerical Studies on the Behaviour of Broad-Gauge Railway Sleepers in Static Bending Condition
- 31 December 2018
- Published by Springer Nature
- p. 781-792
Experimental and Numerical Studies on the Behaviour of Broad-Gauge Railway Sleepers in Static Bending Condition