Do radiological findings around the Fitmore stem change over time?
Open Access
- 1 January 2022
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (1) , 20-28
Abstract
Aims Although the short stem concept in hip arthroplasty procedure shows acceptable clinical performance, we sometimes get unexplainable radiological findings. The aim of this retrospective study was to evaluate changes of radiological findings up to three years postoperatively, and to assess any potential contributing factors on such radiological change in a Japanese population. Methods This is a retrospective radiological study conducted in Japan. Radiological assessment was done in accordance with predetermined radiological review protocol. A total of 241 hips were included in the study and 118 hips (49.0%) revealed radiological change from immediately after surgery to one year postoperatively; these 118 hips were eligible for further analyses. Each investigator screened whether either radiolucent lines (RLLs), cortical hypertrophy (CH), or atrophy (AT) appeared or not on the one-year radiograph. Further, three-year radiographs of eligible cases were reviewed to determine changes such as, disappeared (D), improved (I), stable (S), and progression (P). Additionally, bone condensation (BC) was assessed on the three-year radiograph. Results CH was observed in 49 hips (21.1%), AT was observed in 63 hips (27.2%), and RLLs were observed in 34 hips (14.7%) at one year postoperatively. Among 34 hips with RLLs, 70.6% showed change of either D or I on the three-year radiograph. BC was observed in younger patients more frequently. Conclusion The Fitmore stem works well in a Japanese population with favourable radiological change on hips with RLLs. Longer-term follow-up is required to determine clinical relevance. Cite this article: Bone Jt Open 2022;3(1):20–28.Keywords
This publication has 38 references indexed in Scilit:
- Low BMD affects initial stability and delays stem osseointegration in cementless total hip arthroplasty in womenActa Orthopaedica, 2012
- A Short Tapered Stem Reduces Intraoperative Complications in Primary Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2012
- Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ): a patient-based evaluation tool for hip-joint disease. The Subcommittee on Hip Disease Evaluation of the Clinical Outcome Committee of the Japanese Orthopaedic AssociationJournal of Orthopaedic Science, 2012
- Long-term Results for the Uncemented Zweymuller/Alloclassic Hip EndoprosthesisThe Journal of Arthroplasty, 2009
- Perspectives on metaphyseal conservative stemsJournal of Orthopaedics and Traumatology, 2008
- Influence of changes in stem positioning on femoral loading after THR using a short-stemmed hip implantClinical Biomechanics, 2007
- Ten to Twelve-Year Results With the Zweymüller Cementless Total Hip ProsthesisThe Journal of Arthroplasty, 2005
- Radiological changes in second- and third-generation Zweymüller stemsThe Journal of Bone and Joint Surgery. British volume, 2004
- Recent advances in cementless total hip arthroplasty using the AML prosthesisTechniques in Orthopaedics, 1991
- Distal cortical hypertrophy following total hip arthroplastyThe Journal of Arthroplasty, 1988